title: "PT SURYA PERTAMA INDONESIA Specs (560.0W, 52.73V Voc)"
url: https://epri-peac.com/solar-equipment/modules/pt-surya-pertama-indonesia/pt-surya-pertama-indonesia-lp-560-144mt-b/
description: "CEC datasheet for PT SURYA PERTAMA INDONESIA LP-560-144MT-B: 560.0W STC, 52.73V Voc, 15-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# PT SURYA PERTAMA INDONESIA LP-560-144MT-B — CEC Solar Module Specifications

Manufacturer: [**PT SURYA PERTAMA INDONESIA**](https://epri-peac.com/solar-equipment/brands/pt-surya-pertama-indonesia/) Registry: **CEC Verified Engineering Specification**

PT SURYA PERTAMA INDONESIA LP-560-144MT-B is a 560.0 W STC (532.1 W PTC) Mono-c-Si solar module ranking #2,404 of 21,677 CEC listings (top 11.8%; higher than 88.2% of peers). It delivers 21.71% efficiency, 52.73 V Voc at 25 C, and 57.47 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 560.0 W

- **PTC Wattage** : 532.1 W

- **Voc @ 25C** : 52.73 V

- **Efficiency** : 21.71%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does PT SURYA PERTAMA INDONESIA LP-560-144MT-B Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for PT SURYA PERTAMA INDONESIA LP-560-144MT-B (Mono-c-Si) residential solar systems.

Homeowners evaluating PT SURYA PERTAMA INDONESIA LP-560-144MT-B need 11 panels for 6 kW or 15 panels (417 sq ft) for an 8 kW array—better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. Under NEC 690.7(A), beta_Voc (-0.257%/C) pushes open-circuit voltage to 57.47 V at 14 F and 58.83 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does PT SURYA PERTAMA INDONESIA LP-560-144MT-B Fall Across Listed CEC Models?

Comparison of PT SURYA PERTAMA INDONESIA LP-560-144MT-B (560.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define PT SURYA PERTAMA INDONESIA LP-560-144MT-B?

Relative ranking of PT SURYA PERTAMA INDONESIA LP-560-144MT-B across nameplate watts, 95.0% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for PT SURYA PERTAMA INDONESIA LP-560-144MT-B?

Summary of PT SURYA PERTAMA INDONESIA LP-560-144MT-B output rank, 8 kW array size (15 panels), efficiency rating, and 600 V string limit.

Rank #2,404 / 21,677

### Top 11.8% STC Output

560.0 W STC (+175.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,802

### 21.71% Aperture Efficiency

Power density 217.1 W/m2 (1.80 percentage points above 19.91% CEC median). PTC/STC ratio: 95.0% (rank #1,106).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 57.47 V at -10 C (574.7 V string) and 58.83 V at -20 C (10 max).

 8 kW Reference Array

### 15 Panels = 8,400 W STC

Occupies 38.7 m2 (417 sq ft) producing 7,982 W PTC; NEC 690.8 OCPD floor is 20.03 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 52.73 * (1 + (-0.257/100) * (-10 - 25)) = 57.47 V | OCPD = 1.56 * 12.84 = 20.03 A

Inputs from CEC Modules.csv for PT SURYA PERTAMA INDONESIA LP-560-144MT-B: Voc=52.73 V, beta_Voc=-0.257%/C, Isc=12.84 A, STC=560.0 W, Area=2.58 m2.

**Result:** 10 panels max on 600 V (574.7 V); 15 panels for 8 kW (417 sq ft).

## What Are the Published CEC Specifications for PT SURYA PERTAMA INDONESIA LP-560-144MT-B?

Complete CEC test sheet for PT SURYA PERTAMA INDONESIA LP-560-144MT-B including Isc (12.84 A), Voc (52.73 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for PT SURYA PERTAMA INDONESIA LP-560-144MT-B.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 560.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 532.1 W (95.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 52.73 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 12.84 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 45.9 V / 12.2 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.257 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.71% (2.58 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many PT SURYA PERTAMA INDONESIA LP-560-144MT-B Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using PT SURYA PERTAMA INDONESIA LP-560-144MT-B.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 11 | 6.16 kW | 305 sq ft | $1,542 | $2,607 |
| **8 kW Class** | 15 | 8.4 kW | 417 sq ft | $2,102 | $3,555 |
| **10 kW Class** | 18 | 10.08 kW | 500 sq ft | $2,523 | $4,266 |

## Which Sibling Wattage & Trim Variants Belong to This PT SURYA PERTAMA INDONESIA Series?

Related PT SURYA PERTAMA INDONESIA power steps and black/silver trims consolidated into this PT SURYA PERTAMA INDONESIA LP-560-144MT-B series guide.

Sibling CEC listings grouped into the PT SURYA PERTAMA INDONESIA LP-560-144MT-B wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **PT SURYA PERTAMA INDONESIA LP-550-144MT-B** | 550.0 W | 522.4 W | 52.45 V | 45.6 V | 21.32% |
| **PT SURYA PERTAMA INDONESIA LP-555-144MT-B** | 555.0 W | 527.3 W | 52.59 V | 45.75 V | 21.51% |
| **PT SURYA PERTAMA INDONESIA LP-560-144MT-B** | 560.0 W | 532.1 W | 52.73 V | 45.9 V | 21.71% |
| **PT SURYA PERTAMA INDONESIA LP-565-144MT-B** | 565.0 W | 537.0 W | 52.87 V | 46.04 V | 21.9% |
| **PT SURYA PERTAMA INDONESIA LP-570-144MT-B** | 570.0 W | 541.9 W | 53.01 V | 46.19 V | 22.09% |

## How Many PT SURYA PERTAMA INDONESIA LP-560-144MT-B Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for PT SURYA PERTAMA INDONESIA LP-560-144MT-B (52.73 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=52.73V and beta_Voc=-0.257%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 58.83 V | 10 panels | 588.3 V | 16 panels |
| **-10 C (14 F)** | 57.47 V | 10 panels | 574.7 V | 17 panels |
| **0 C (32 F)** | 56.12 V | 10 panels | 561.2 V | 17 panels |
| **25 C (77 F STC)** | 52.73 V | 11 panels | 580.0 V | 18 panels |

## Which Cross-Brand Solar Modules Compare Closest to PT SURYA PERTAMA INDONESIA LP-560-144MT-B?

Four comparable CEC modules such as FreeVolt ECP-PVGRAF-HC-BF560-144MT-B (560.0 W) for side-by-side solar quote checks. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**FreeVolt ECP-PVGRAF-HC-BF560-144MT-B**](https://epri-peac.com/solar-equipment/modules/freevolt/freevolt-ecp-pvgraf-hc-bf560-144mt-b/) FreeVolt | 560.0 W | Tie (0 W) | 52.7 V | 21.71% | 95.0% |
| [**FreeVolt ECP-PVGRAF-HC-BF560-144MT-W**](https://epri-peac.com/solar-equipment/modules/freevolt/freevolt-ecp-pvgraf-hc-bf560-144mt-w/) FreeVolt | 560.0 W | Tie (0 W) | 52.7 V | 21.71% | 95.0% |
| [**Auxin Solar AXN10M560W**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m560w/) Auxin Solar | 560.0 W | Tie (0 W) | 52.48 V | 21.88% | 91.8% |
| [**Boviet Solar Technology Co Ltd BVM7612M-560-H-HC**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7612m-560-h-hc/) Boviet Solar Technology Co Ltd | 560.0 W | Tie (0 W) | 51.66 V | 21.71% | 95.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for PT SURYA PERTAMA INDONESIA LP-560-144MT-B?

Evaluate PT SURYA PERTAMA INDONESIA LP-560-144MT-B (560.0 W STC, 52.73 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), PT SURYA PERTAMA INDONESIA LP-560-144MT-B reaches 58.83 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of PT SURYA PERTAMA INDONESIA LP-560-144MT-B carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### PT SURYA PERTAMA INDONESIA LP-560-144MT-B 8 kW Residential Fit

Needs 15 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare FreeVolt ECP-PVGRAF-HC-BF560-144MT-B.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 532.1 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PT SURYA PERTAMA INDONESIA LP-560-144MT-B by PT SURYA PERTAMA INDONESIA grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is PT SURYA PERTAMA INDONESIA LP-560-144MT-B PTC wattage (532.1 W) lower than STC (560.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 532.1 W PTC (95.0% retention) across PT SURYA PERTAMA INDONESIA LP-560-144MT-B's 2.58 m2 aperture.

### Who should skip PT SURYA PERTAMA INDONESIA LP-560-144MT-B on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 15 PT SURYA PERTAMA INDONESIA LP-560-144MT-B panels (417 sq ft) leave unusable roof gaps vs. FreeVolt ECP-PVGRAF-HC-BF560-144MT-B.

### What is the 1,000 V commercial string limit for PT SURYA PERTAMA INDONESIA LP-560-144MT-B?

On 1,000 V commercial inverters at -10 C (57.47 V cold Voc), PT SURYA PERTAMA INDONESIA LP-560-144MT-B fits up to 17 panels per series string.

## Related Pages

Compare PT SURYA PERTAMA INDONESIA equipment, FreeVolt ECP-PVGRAF-HC-BF560-144MT-B specs, utility payback rates, and NEC string calculators alongside PT SURYA PERTAMA INDONESIA LP-560-144MT-B.

[All PT SURYA PERTAMA INDONESIA Certified Solar Models](https://epri-peac.com/solar-equipment/brands/pt-surya-pertama-indonesia/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From PT SURYA PERTAMA INDONESIA

- [All PT SURYA PERTAMA INDONESIA Specs](https://epri-peac.com/solar-equipment/brands/pt-surya-pertama-indonesia/)
- [PT SURYA PERTAMA INDONESIA LP-585-144MT-B](https://epri-peac.com/solar-equipment/modules/pt-surya-pertama-indonesia/pt-surya-pertama-indonesia-lp-585-144mt-b/)
- [PT SURYA PERTAMA INDONESIA LP-585-144MT-W](https://epri-peac.com/solar-equipment/modules/pt-surya-pertama-indonesia/pt-surya-pertama-indonesia-lp-585-144mt-w/)
- [PT SURYA PERTAMA INDONESIA LP-560-144MT-W](https://epri-peac.com/solar-equipment/modules/pt-surya-pertama-indonesia/pt-surya-pertama-indonesia-lp-560-144mt-w/)