title: "PT NUSA SOLAR INDONESIA Specs (600.0W, 53.3V Voc)"
url: https://epri-peac.com/solar-equipment/modules/pt-nusa-solar-indonesia/pt-nusa-solar-indonesia-ns600m10t-b72yy/
description: "CEC datasheet for PT NUSA SOLAR INDONESIA NS600M10T-B72yy: 600.0W STC, 53.3V Voc, 14-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# PT NUSA SOLAR INDONESIA NS600M10T-B72yy — CEC Solar Module Specifications

Manufacturer: [**PT NUSA SOLAR INDONESIA**](https://epri-peac.com/solar-equipment/brands/pt-nusa-solar-indonesia/) Registry: **CEC Verified Engineering Specification**

PT NUSA SOLAR INDONESIA NS600M10T-B72yy is a 600.0 W STC (564.8 W PTC) Mono-c-Si solar module ranking #1,320 of 21,677 CEC listings (top 6.7%; higher than 93.3% of peers). It delivers 23.26% efficiency, 53.3 V Voc at 25 C, and 57.74 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 600.0 W

- **PTC Wattage** : 564.8 W

- **Voc @ 25C** : 53.3 V

- **Efficiency** : 23.26%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does PT NUSA SOLAR INDONESIA NS600M10T-B72yy Compare Against Peer CEC Listings?

How PT NUSA SOLAR INDONESIA PT NUSA SOLAR INDONESIA NS600M10T-B72yy handles rooftop heat (564.8 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, PT NUSA SOLAR INDONESIA NS600M10T-B72yy exhibits 14.23 A short-circuit current, requiring a 22.2 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #1,320 of 21,677 (190.0 W above the 410.0 W Mono-c-Si median), this large-format commercial and ground-mount module covers 36.1 m2 for an 8 kW system (17 panels for 10 kW). Higher 53.3 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

## Where Does PT NUSA SOLAR INDONESIA NS600M10T-B72yy Fall Across Listed CEC Models?

Where PT NUSA SOLAR INDONESIA NS600M10T-B72yy (600.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define PT NUSA SOLAR INDONESIA NS600M10T-B72yy?

Percentile placement of PT NUSA SOLAR INDONESIA NS600M10T-B72yy across power density (232.6 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for PT NUSA SOLAR INDONESIA NS600M10T-B72yy?

Four critical engineering numbers homeowners and solar installers check first when reviewing PT NUSA SOLAR INDONESIA NS600M10T-B72yy specifications.

Rank #1,320 / 21,677

### Top 6.7% STC Output

600.0 W STC (+215.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #770

### 23.26% Aperture Efficiency

Power density 232.6 W/m2 (3.35 percentage points above 19.91% CEC median). PTC/STC ratio: 94.1% (rank #4,203).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 57.74 V at -10 C (577.4 V string) and 59.01 V at -20 C (10 max).

 8 kW Reference Array

### 14 Panels = 8,400 W STC

Occupies 36.1 m2 (389 sq ft) producing 7,907 W PTC; NEC 690.8 OCPD floor is 22.2 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 53.3 * (1 + (-0.238/100) * (-10 - 25)) = 57.74 V | OCPD = 1.56 * 14.23 = 22.2 A

Inputs from CEC Modules.csv for PT NUSA SOLAR INDONESIA NS600M10T-B72yy: Voc=53.3 V, beta_Voc=-0.238%/C, Isc=14.23 A, STC=600.0 W, Area=2.58 m2.

**Result:** 10 panels max on 600 V (577.4 V); 14 panels for 8 kW (389 sq ft).

## What Are the Published CEC Specifications for PT NUSA SOLAR INDONESIA NS600M10T-B72yy?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for PT NUSA SOLAR INDONESIA NS600M10T-B72yy.

Official California Energy Commission (NREL SAM) test parameters for PT NUSA SOLAR INDONESIA NS600M10T-B72yy.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 600.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 564.8 W (94.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 53.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 14.23 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 44.61 V / 13.47 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.238 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 23.26% (2.58 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many PT NUSA SOLAR INDONESIA NS600M10T-B72yy Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using PT NUSA SOLAR INDONESIA NS600M10T-B72yy (600.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 10 | 6.0 kW | 278 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 14 | 8.4 kW | 389 sq ft | $2,102 | $3,555 |
| **10 kW Class** | 17 | 10.2 kW | 472 sq ft | $2,553 | $4,317 |

## How Many PT NUSA SOLAR INDONESIA NS600M10T-B72yy Modules Fit in a Cold-Weather String?

Maximum series module counts for PT NUSA SOLAR INDONESIA NS600M10T-B72yy from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=53.3V and beta_Voc=-0.238%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 59.01 V | 10 panels | 590.1 V | 16 panels |
| **-10 C (14 F)** | 57.74 V | 10 panels | 577.4 V | 17 panels |
| **0 C (32 F)** | 56.47 V | 10 panels | 564.7 V | 17 panels |
| **25 C (77 F STC)** | 53.3 V | 11 panels | 586.3 V | 18 panels |

## Which Cross-Brand Solar Modules Compare Closest to PT NUSA SOLAR INDONESIA NS600M10T-B72yy?

Alternative CEC solar modules from competing brands near PT NUSA SOLAR INDONESIA NS600M10T-B72yy (600.0 W), including Hengdian Group DMEGC Magnetics Co Ltd DM600M10T-B72yyy.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Hengdian Group DMEGC Magnetics Co Ltd DM600M10T-B72yyy**](https://epri-peac.com/solar-equipment/modules/hengdian-group-dmegc-magnetics-co-ltd/hengdian-group-dmegc-magnetics-co-ltd-dm600m10t-b72yyy/) Hengdian Group DMEGC Magnetics Co Ltd | 600.0 W | Tie (0 W) | 53.3 V | 23.26% | 94.1% |
| [**Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE78-18X-600**](https://epri-peac.com/solar-equipment/modules/jiangsu-xiehang-new-energy-intelligent-equipment-co-ltd/jiangsu-xiehang-new-energy-intelligent-equipment-co-ltd-fe78-18x-600/) Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd | 600.0 W | Tie (0 W) | 54.09 V | 21.43% | 93.2% |
| [**LIGHT ENGINE ILUMINACAO SA HS78-600-MN**](https://epri-peac.com/solar-equipment/modules/light-engine-iluminacao-sa/light-engine-iluminacao-sa-hs78-600-mn/) LIGHT ENGINE ILUMINACAO SA | 600.0 W | Tie (0 W) | 54.1 V | 22.06% | 94.2% |
| [**Hansol Technics Co Ltd HA600-AD-NNEA0**](https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-ha600-ad-nnea0/) Hansol Technics Co Ltd | 600.0 W | Tie (0 W) | 52.3 V | 23.44% | 93.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for PT NUSA SOLAR INDONESIA NS600M10T-B72yy?

Evaluate PT NUSA SOLAR INDONESIA NS600M10T-B72yy (600.0 W STC, 53.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), PT NUSA SOLAR INDONESIA NS600M10T-B72yy reaches 59.01 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 389 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of PT NUSA SOLAR INDONESIA NS600M10T-B72yy carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### PT NUSA SOLAR INDONESIA NS600M10T-B72yy 8 kW Residential Fit

Needs 14 modules (389 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Hengdian Group DMEGC Magnetics Co Ltd DM600M10T-B72yyy.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 564.8 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PT NUSA SOLAR INDONESIA NS600M10T-B72yy by PT NUSA SOLAR INDONESIA grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is PT NUSA SOLAR INDONESIA NS600M10T-B72yy PTC wattage (564.8 W) lower than STC (600.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 564.8 W PTC (94.1% retention) across PT NUSA SOLAR INDONESIA NS600M10T-B72yy's 2.58 m2 aperture.

### Who should skip PT NUSA SOLAR INDONESIA NS600M10T-B72yy on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 14 PT NUSA SOLAR INDONESIA NS600M10T-B72yy panels (389 sq ft) leave unusable roof gaps vs. Hengdian Group DMEGC Magnetics Co Ltd DM600M10T-B72yyy.

### What is the 1,000 V commercial string limit for PT NUSA SOLAR INDONESIA NS600M10T-B72yy?

On 1,000 V commercial inverters at -10 C (57.74 V cold Voc), PT NUSA SOLAR INDONESIA NS600M10T-B72yy fits up to 17 panels per series string.

## Related Pages

Compare PT NUSA SOLAR INDONESIA equipment, Hengdian Group DMEGC Magnetics Co Ltd DM600M10T-B72yyy specs, utility payback rates, and NEC string calculators alongside PT NUSA SOLAR INDONESIA NS600M10T-B72yy.

[All PT NUSA SOLAR INDONESIA Certified Solar Models](https://epri-peac.com/solar-equipment/brands/pt-nusa-solar-indonesia/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From PT NUSA SOLAR INDONESIA

- [All PT NUSA SOLAR INDONESIA Specs](https://epri-peac.com/solar-equipment/brands/pt-nusa-solar-indonesia/)
- [PT NUSA SOLAR INDONESIA NS635G12RT-B66yy](https://epri-peac.com/solar-equipment/modules/pt-nusa-solar-indonesia/pt-nusa-solar-indonesia-ns635g12rt-b66yy/)
- [PT NUSA SOLAR INDONESIA NS635M10T-B78yy](https://epri-peac.com/solar-equipment/modules/pt-nusa-solar-indonesia/pt-nusa-solar-indonesia-ns635m10t-b78yy/)
- [PT NUSA SOLAR INDONESIA NS610G12RT-B66yy](https://epri-peac.com/solar-equipment/modules/pt-nusa-solar-indonesia/pt-nusa-solar-indonesia-ns610g12rt-b66yy/)
- [PT NUSA SOLAR INDONESIA NS610M10T-B78yy](https://epri-peac.com/solar-equipment/modules/pt-nusa-solar-indonesia/pt-nusa-solar-indonesia-ns610m10t-b78yy/)
- [PT NUSA SOLAR INDONESIA NS585M10T-B72yy](https://epri-peac.com/solar-equipment/modules/pt-nusa-solar-indonesia/pt-nusa-solar-indonesia-ns585m10t-b72yy/)