title: "PT NUSA SOLAR INDONESIA Specs (460.0W, 40.65V Voc)"
url: https://epri-peac.com/solar-equipment/modules/pt-nusa-solar-indonesia/pt-nusa-solar-indonesia-ns460m10rt-b54yy/
description: "CEC datasheet for PT NUSA SOLAR INDONESIA NS460M10RT-B54yy: 460.0W STC, 40.65V Voc, 18-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# PT NUSA SOLAR INDONESIA NS460M10RT-B54yy — CEC Solar Module Specifications

Manufacturer: [**PT NUSA SOLAR INDONESIA**](https://epri-peac.com/solar-equipment/brands/pt-nusa-solar-indonesia/) Registry: **CEC Verified Engineering Specification**

PT NUSA SOLAR INDONESIA NS460M10RT-B54yy is a 460.0 W STC (433.1 W PTC) Mono-c-Si solar module ranking #5,199 of 21,677 CEC listings (top 25.0%; higher than 75.0% of peers). It delivers 23.12% efficiency, 40.65 V Voc at 25 C, and 43.95 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 460.0 W

- **PTC Wattage** : 433.1 W

- **Voc @ 25C** : 40.65 V

- **Efficiency** : 23.12%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does PT NUSA SOLAR INDONESIA NS460M10RT-B54yy Compare Against Peer CEC Listings?

Solar engineering breakdown for PT NUSA SOLAR INDONESIA NS460M10RT-B54yy: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 460.0 W STC and 433.1 W PTC, PT NUSA SOLAR INDONESIA NS460M10RT-B54yy sits +75.0 W vs all-CEC median (top 25.0%; higher than 75.0% of peers) among 21,677 listed modules. Power density reaches 231.2 W/m2 (3.21 percentage points above 19.91% CEC median). Mid-range 40.65 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 22 panels in series. Alternative peer Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460 rates 460.0 W.

## Where Does PT NUSA SOLAR INDONESIA NS460M10RT-B54yy Fall Across Listed CEC Models?

Distribution marker showing PT NUSA SOLAR INDONESIA NS460M10RT-B54yy (460.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define PT NUSA SOLAR INDONESIA NS460M10RT-B54yy?

Dataset percentiles tracking PT NUSA SOLAR INDONESIA NS460M10RT-B54yy power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for PT NUSA SOLAR INDONESIA NS460M10RT-B54yy?

Benchmark highlights for PT NUSA SOLAR INDONESIA NS460M10RT-B54yy covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #5,199 / 21,677

### Top 25.0% STC Output

460.0 W STC (+75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #962

### 23.12% Aperture Efficiency

Power density 231.2 W/m2 (3.21 percentage points above 19.91% CEC median). PTC/STC ratio: 94.2% (rank #3,689).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.95 V at -10 C (571.4 V string) and 44.89 V at -20 C (13 max).

 8 kW Reference Array

### 18 Panels = 8,280 W STC

Occupies 35.8 m2 (386 sq ft) producing 7,796 W PTC; NEC 690.8 OCPD floor is 22.32 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.65 * (1 + (-0.232/100) * (-10 - 25)) = 43.95 V | OCPD = 1.56 * 14.31 = 22.32 A

Inputs from CEC Modules.csv for PT NUSA SOLAR INDONESIA NS460M10RT-B54yy: Voc=40.65 V, beta_Voc=-0.232%/C, Isc=14.31 A, STC=460.0 W, Area=1.99 m2.

**Result:** 13 panels max on 600 V (571.4 V); 18 panels for 8 kW (386 sq ft).

## What Are the Published CEC Specifications for PT NUSA SOLAR INDONESIA NS460M10RT-B54yy?

Official CEC datasheet figures for PT NUSA SOLAR INDONESIA NS460M10RT-B54yy (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for PT NUSA SOLAR INDONESIA NS460M10RT-B54yy.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 460.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 433.1 W (94.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 40.65 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 14.31 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 34.31 V / 13.41 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.232 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 23.12% (1.99 m2) | Array roof footprint density |
| **Cell Count & Technology** | 54 cells (Mono-c-Si) | Monofacial backsheet |

## How Many PT NUSA SOLAR INDONESIA NS460M10RT-B54yy Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many PT NUSA SOLAR INDONESIA NS460M10RT-B54yy modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 14 | 6.44 kW | 300 sq ft | $1,612 | $2,726 |
| **8 kW Class** | 18 | 8.28 kW | 386 sq ft | $2,072 | $3,504 |
| **10 kW Class** | 22 | 10.12 kW | 471 sq ft | $2,533 | $4,283 |

## Which Sibling Wattage & Trim Variants Belong to This PT NUSA SOLAR INDONESIA Series?

Consolidated PT NUSA SOLAR INDONESIA wattage variants sharing the PT NUSA SOLAR INDONESIA NS460M10RT-B54yy mechanical and cell layout.

Sibling CEC listings grouped into the PT NUSA SOLAR INDONESIA NS460M10RT-B54yy wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **PT NUSA SOLAR INDONESIA NS450M10RT-B54yy** | 450.0 W | 423.5 W | 40.25 V | 33.91 V | 22.61% |
| **PT NUSA SOLAR INDONESIA NS455M10RT-B54yy** | 455.0 W | 428.3 W | 40.45 V | 34.11 V | 22.86% |
| **PT NUSA SOLAR INDONESIA NS460M10RT-B54yy** | 460.0 W | 433.1 W | 40.65 V | 34.31 V | 23.12% |
| **PT NUSA SOLAR INDONESIA NS465M10RT-B54yy** | 465.0 W | 438.0 W | 40.85 V | 34.51 V | 23.37% |

## How Many PT NUSA SOLAR INDONESIA NS460M10RT-B54yy Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on PT NUSA SOLAR INDONESIA NS460M10RT-B54yy (43.95 V at 14 F).

Computed from Voc=40.65V and beta_Voc=-0.232%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 44.89 V | 13 panels | 583.6 V | 22 panels |
| **-10 C (14 F)** | 43.95 V | 13 panels | 571.4 V | 22 panels |
| **0 C (32 F)** | 43.01 V | 13 panels | 559.1 V | 23 panels |
| **25 C (77 F STC)** | 40.65 V | 14 panels | 569.1 V | 24 panels |

## Which Cross-Brand Solar Modules Compare Closest to PT NUSA SOLAR INDONESIA NS460M10RT-B54yy?

Competing CEC solar panels closest to PT NUSA SOLAR INDONESIA NS460M10RT-B54yy in nameplate wattage and Voc, starting with Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460**](https://epri-peac.com/solar-equipment/modules/elin-energy-sirius-pv/elin-energy-sirius-pv-elnsm54m-hc-lv-n-460/) Elin Energy (Sirius PV) | 460.0 W | Tie (0 W) | 40.1 V | 23.71% | 95.2% |
| [**Elin Energy (Sirius PV) ELNSM54M-HC-N-460**](https://epri-peac.com/solar-equipment/modules/elin-energy-sirius-pv/elin-energy-sirius-pv-elnsm54m-hc-n-460/) Elin Energy (Sirius PV) | 460.0 W | Tie (0 W) | 40.1 V | 23.71% | 95.2% |
| [**Auxin Solar AXN10M460W**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m460w/) Auxin Solar | 460.0 W | Tie (0 W) | 39.88 V | 23.71% | 92.0% |
| [**Aptos Solar Technology LLC DNA-120-BF10-460W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-120-bf10-460w/) Aptos Solar Technology LLC | 460.0 W | Tie (0 W) | 41.5 V | 21.3% | 94.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for PT NUSA SOLAR INDONESIA NS460M10RT-B54yy?

Evaluate PT NUSA SOLAR INDONESIA NS460M10RT-B54yy (460.0 W STC, 40.65 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), PT NUSA SOLAR INDONESIA NS460M10RT-B54yy reaches 44.89 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 386 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (386 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of PT NUSA SOLAR INDONESIA NS460M10RT-B54yy carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### PT NUSA SOLAR INDONESIA NS460M10RT-B54yy 8 kW Residential Fit

Needs 18 modules (386 sq ft) with a 25 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 433.1 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PT NUSA SOLAR INDONESIA NS460M10RT-B54yy by PT NUSA SOLAR INDONESIA grounded in CEC test data and NEC 690.7/690.8 limits.

### How many PT NUSA SOLAR INDONESIA NS460M10RT-B54yy panels fit on a 600 V winter solar string?

At -10 C (14 F), PT NUSA SOLAR INDONESIA NS460M10RT-B54yy cold Voc rises from 40.65 V to 43.95 V (beta_Voc -0.232%/C), capping a 600 V string at 13 panels (571.4 V).

### How much roof area does an 8 kW array of PT NUSA SOLAR INDONESIA NS460M10RT-B54yy need?

An 8 kW DC system uses 18 PT NUSA SOLAR INDONESIA NS460M10RT-B54yy modules (8,280 W STC / 7,796 W PTC), covering roughly 386 sq ft and saving ~$2,072/yr at 18.54 c/kWh.

### How does PT NUSA SOLAR INDONESIA NS460M10RT-B54yy compare against Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460?

PT NUSA SOLAR INDONESIA NS460M10RT-B54yy outputs 460.0 W STC (40.65 V Voc, rank #5,199 of 21,677), while Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460 delivers 460.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare PT NUSA SOLAR INDONESIA equipment, Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460 specs, utility payback rates, and NEC string calculators alongside PT NUSA SOLAR INDONESIA NS460M10RT-B54yy.

[All PT NUSA SOLAR INDONESIA Certified Solar Models](https://epri-peac.com/solar-equipment/brands/pt-nusa-solar-indonesia/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From PT NUSA SOLAR INDONESIA

- [All PT NUSA SOLAR INDONESIA Specs](https://epri-peac.com/solar-equipment/brands/pt-nusa-solar-indonesia/)
- [PT NUSA SOLAR INDONESIA NS635G12RT-B66yy](https://epri-peac.com/solar-equipment/modules/pt-nusa-solar-indonesia/pt-nusa-solar-indonesia-ns635g12rt-b66yy/)
- [PT NUSA SOLAR INDONESIA NS635M10T-B78yy](https://epri-peac.com/solar-equipment/modules/pt-nusa-solar-indonesia/pt-nusa-solar-indonesia-ns635m10t-b78yy/)
- [PT NUSA SOLAR INDONESIA NS610G12RT-B66yy](https://epri-peac.com/solar-equipment/modules/pt-nusa-solar-indonesia/pt-nusa-solar-indonesia-ns610g12rt-b66yy/)
- [PT NUSA SOLAR INDONESIA NS610M10T-B78yy](https://epri-peac.com/solar-equipment/modules/pt-nusa-solar-indonesia/pt-nusa-solar-indonesia-ns610m10t-b78yy/)
- [PT NUSA SOLAR INDONESIA NS600M10T-B72yy](https://epri-peac.com/solar-equipment/modules/pt-nusa-solar-indonesia/pt-nusa-solar-indonesia-ns600m10t-b72yy/)