title: "PT NUSA SOLAR INDONESIA Specs (415.0W, 38.84V Voc)"
url: https://epri-peac.com/solar-equipment/modules/pt-nusa-solar-indonesia/pt-nusa-solar-indonesia-ns415m10t-b54yy/
description: "CEC datasheet for PT NUSA SOLAR INDONESIA NS415M10T-B54yy: 415.0W STC, 38.84V Voc, 20-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# PT NUSA SOLAR INDONESIA NS415M10T-B54yy — CEC Solar Module Specifications

Manufacturer: [**PT NUSA SOLAR INDONESIA**](https://epri-peac.com/solar-equipment/brands/pt-nusa-solar-indonesia/) Registry: **CEC Verified Engineering Specification**

PT NUSA SOLAR INDONESIA NS415M10T-B54yy is a 415.0 W STC (389.7 W PTC) Mono-c-Si solar module ranking #8,199 of 21,677 CEC listings (top 39.4%; higher than 60.6% of peers). It delivers 21.28% efficiency, 38.84 V Voc at 25 C, and 42.12 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 415.0 W

- **PTC Wattage** : 389.7 W

- **Voc @ 25C** : 38.84 V

- **Efficiency** : 21.28%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does PT NUSA SOLAR INDONESIA NS415M10T-B54yy Compare Against Peer CEC Listings?

How PT NUSA SOLAR INDONESIA PT NUSA SOLAR INDONESIA NS415M10T-B54yy handles rooftop heat (389.7 W PTC), 8 kW sizing, and cold winter string voltage.

PT NUSA SOLAR INDONESIA builds the PT NUSA SOLAR INDONESIA NS415M10T-B54yy (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 212.8 W/m2 (1.37 percentage points above 19.91% CEC median). Compared against Boviet Solar Technology Co Ltd BVM7609M-415-H-HC (415.0 W), this model holds strong 93.9% PTC-to-STC heat retention (#5,210 of 21,677). Lower 38.84 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 21.33 A overcurrent floor served by a 25 A breaker.

## Where Does PT NUSA SOLAR INDONESIA NS415M10T-B54yy Fall Across Listed CEC Models?

Where PT NUSA SOLAR INDONESIA NS415M10T-B54yy (415.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define PT NUSA SOLAR INDONESIA NS415M10T-B54yy?

Percentile placement of PT NUSA SOLAR INDONESIA NS415M10T-B54yy across power density (212.8 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for PT NUSA SOLAR INDONESIA NS415M10T-B54yy?

Four critical engineering numbers homeowners and solar installers check first when reviewing PT NUSA SOLAR INDONESIA NS415M10T-B54yy specifications.

Rank #8,199 / 21,677

### Top 39.4% STC Output

415.0 W STC (+30.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,257

### 21.28% Aperture Efficiency

Power density 212.8 W/m2 (1.37 percentage points above 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.12 V at -10 C (589.7 V string) and 43.05 V at -20 C (13 max).

 8 kW Reference Array

### 20 Panels = 8,300 W STC

Occupies 39.0 m2 (420 sq ft) producing 7,794 W PTC; NEC 690.8 OCPD floor is 21.33 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.84 * (1 + (-0.241/100) * (-10 - 25)) = 42.12 V | OCPD = 1.56 * 13.67 = 21.33 A

Inputs from CEC Modules.csv for PT NUSA SOLAR INDONESIA NS415M10T-B54yy: Voc=38.84 V, beta_Voc=-0.241%/C, Isc=13.67 A, STC=415.0 W, Area=1.95 m2.

**Result:** 14 panels max on 600 V (589.7 V); 20 panels for 8 kW (420 sq ft).

## What Are the Published CEC Specifications for PT NUSA SOLAR INDONESIA NS415M10T-B54yy?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for PT NUSA SOLAR INDONESIA NS415M10T-B54yy.

Official California Energy Commission (NREL SAM) test parameters for PT NUSA SOLAR INDONESIA NS415M10T-B54yy.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 415.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 389.7 W (93.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 38.84 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.67 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 32.23 V / 12.89 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.241 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.28% (1.95 m2) | Array roof footprint density |
| **Cell Count & Technology** | 54 cells (Mono-c-Si) | Monofacial backsheet |

## How Many PT NUSA SOLAR INDONESIA NS415M10T-B54yy Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using PT NUSA SOLAR INDONESIA NS415M10T-B54yy (415.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 15 | 6.22 kW | 315 sq ft | $1,557 | $2,632 |
| **8 kW Class** | 20 | 8.3 kW | 420 sq ft | $2,077 | $3,513 |
| **10 kW Class** | 25 | 10.38 kW | 525 sq ft | $2,598 | $4,393 |

## Which Sibling Wattage & Trim Variants Belong to This PT NUSA SOLAR INDONESIA Series?

All closely matched PT NUSA SOLAR INDONESIA wattages and cosmetic trims sharing the PT NUSA SOLAR INDONESIA NS415M10T-B54yy architecture.

Sibling CEC listings grouped into the PT NUSA SOLAR INDONESIA NS415M10T-B54yy wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **PT NUSA SOLAR INDONESIA NS405M10T-B54yy** | 405.0 W | 380.1 W | 38.44 V | 31.83 V | 20.77% |
| **PT NUSA SOLAR INDONESIA NS410M10T-B54yy** | 410.0 W | 384.9 W | 38.64 V | 32.03 V | 21.03% |
| **PT NUSA SOLAR INDONESIA NS415M10T-B54yy** | 415.0 W | 389.7 W | 38.84 V | 32.23 V | 21.28% |
| **PT NUSA SOLAR INDONESIA NS420M10T-B54yy** | 420.0 W | 394.6 W | 39.04 V | 32.43 V | 21.54% |

## How Many PT NUSA SOLAR INDONESIA NS415M10T-B54yy Modules Fit in a Cold-Weather String?

Maximum series module counts for PT NUSA SOLAR INDONESIA NS415M10T-B54yy from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=38.84V and beta_Voc=-0.241%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 43.05 V | 13 panels | 559.6 V | 23 panels |
| **-10 C (14 F)** | 42.12 V | 14 panels | 589.7 V | 23 panels |
| **0 C (32 F)** | 41.18 V | 14 panels | 576.5 V | 24 panels |
| **25 C (77 F STC)** | 38.84 V | 15 panels | 582.6 V | 25 panels |

## Which Cross-Brand Solar Modules Compare Closest to PT NUSA SOLAR INDONESIA NS415M10T-B54yy?

Alternative CEC solar modules from competing brands near PT NUSA SOLAR INDONESIA NS415M10T-B54yy (415.0 W), including Boviet Solar Technology Co Ltd BVM7609M-415-H-HC.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Boviet Solar Technology Co Ltd BVM7609M-415-H-HC**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7609m-415-h-hc/) Boviet Solar Technology Co Ltd | 415.0 W | Tie (0 W) | 38.47 V | 19.21% | 94.7% |
| [**AXITEC AC-415TGB/108BB**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-415tgb-108bb/) AXITEC | 415.0 W | Tie (0 W) | 38.04 V | 21.84% | 94.9% |
| [**Aptos Solar Technology LLC DNA-108-MF10-415W-USAptos1a**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mf10-415w-usaptos1a/) Aptos Solar Technology LLC | 415.0 W | Tie (0 W) | 37.7 V | 21.39% | 93.0% |
| [**Aptos Solar Technology LLC DNA-108-BF10-415W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-bf10-415w/) Aptos Solar Technology LLC | 415.0 W | Tie (0 W) | 37.5 V | 21.28% | 94.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for PT NUSA SOLAR INDONESIA NS415M10T-B54yy?

Evaluate PT NUSA SOLAR INDONESIA NS415M10T-B54yy (415.0 W STC, 38.84 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), PT NUSA SOLAR INDONESIA NS415M10T-B54yy reaches 43.05 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 420 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of PT NUSA SOLAR INDONESIA NS415M10T-B54yy carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### PT NUSA SOLAR INDONESIA NS415M10T-B54yy 8 kW Residential Fit

Needs 20 modules (420 sq ft) with a 25 A string OCPD, offsetting ~$2,077/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM7609M-415-H-HC.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 389.7 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PT NUSA SOLAR INDONESIA NS415M10T-B54yy by PT NUSA SOLAR INDONESIA grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for PT NUSA SOLAR INDONESIA NS415M10T-B54yy?

Multiplying PT NUSA SOLAR INDONESIA NS415M10T-B54yy's 13.67 A short-circuit current by 1.56 equals 21.33 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can PT NUSA SOLAR INDONESIA NS415M10T-B54yy pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 42.12 V cold Voc at 14 F and handles 13.67 A Isc; string inverters cap PT NUSA SOLAR INDONESIA NS415M10T-B54yy at 14 panels on 600 V.

### Is PT NUSA SOLAR INDONESIA NS415M10T-B54yy eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of PT NUSA SOLAR INDONESIA NS415M10T-B54yy rely on utility bill offset (~$2,077/yr at 8 kW) rather than 25D.

## Related Pages

Compare PT NUSA SOLAR INDONESIA equipment, Boviet Solar Technology Co Ltd BVM7609M-415-H-HC specs, utility payback rates, and NEC string calculators alongside PT NUSA SOLAR INDONESIA NS415M10T-B54yy.

[All PT NUSA SOLAR INDONESIA Certified Solar Models](https://epri-peac.com/solar-equipment/brands/pt-nusa-solar-indonesia/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From PT NUSA SOLAR INDONESIA

- [All PT NUSA SOLAR INDONESIA Specs](https://epri-peac.com/solar-equipment/brands/pt-nusa-solar-indonesia/)
- [PT NUSA SOLAR INDONESIA NS635G12RT-B66yy](https://epri-peac.com/solar-equipment/modules/pt-nusa-solar-indonesia/pt-nusa-solar-indonesia-ns635g12rt-b66yy/)
- [PT NUSA SOLAR INDONESIA NS635M10T-B78yy](https://epri-peac.com/solar-equipment/modules/pt-nusa-solar-indonesia/pt-nusa-solar-indonesia-ns635m10t-b78yy/)
- [PT NUSA SOLAR INDONESIA NS610G12RT-B66yy](https://epri-peac.com/solar-equipment/modules/pt-nusa-solar-indonesia/pt-nusa-solar-indonesia-ns610g12rt-b66yy/)
- [PT NUSA SOLAR INDONESIA NS610M10T-B78yy](https://epri-peac.com/solar-equipment/modules/pt-nusa-solar-indonesia/pt-nusa-solar-indonesia-ns610m10t-b78yy/)
- [PT NUSA SOLAR INDONESIA NS600M10T-B72yy](https://epri-peac.com/solar-equipment/modules/pt-nusa-solar-indonesia/pt-nusa-solar-indonesia-ns600m10t-b72yy/)