# PT LESSO NEW ENERGY 480C(HWB)60(182) — CEC Solar Module Specifications

Manufacturer: [**PT LESSO NEW ENERGY**](https://epri-peac.com/solar-equipment/brands/pt-lesso-new-energy/) Registry: **CEC Verified Engineering Specification**

PT LESSO NEW ENERGY 480C(HWB)60(182) is a 480.0 W STC (454.0 W PTC) Mono-c-Si solar module ranking #4,809 of 21,677 CEC listings (top 22.6%; higher than 77.4% of peers). It delivers 22.22% efficiency, 43.52 V Voc at 25 C, and 47.27 V cold Voc at -10 C (12 panels max per 600 V string).

- **STC Wattage** : 480.0 W

- **PTC Wattage** : 454.0 W

- **Voc @ 25C** : 43.52 V

- **Efficiency** : 22.22%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does PT LESSO NEW ENERGY 480C(HWB)60(182) Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for PT LESSO NEW ENERGY 480C(HWB)60(182) (Mono-c-Si) residential solar systems.

Homeowners evaluating PT LESSO NEW ENERGY 480C(HWB)60(182) need 13 panels for 6 kW or 17 panels (395 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 17 panels (395 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.246%/C) pushes open-circuit voltage to 47.27 V at 14 F and 48.34 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does PT LESSO NEW ENERGY 480C(HWB)60(182) Fall Across Listed CEC Models?

Comparison of PT LESSO NEW ENERGY 480C(HWB)60(182) (480.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define PT LESSO NEW ENERGY 480C(HWB)60(182)?

Relative ranking of PT LESSO NEW ENERGY 480C(HWB)60(182) across nameplate watts, 94.6% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for PT LESSO NEW ENERGY 480C(HWB)60(182)?

Summary of PT LESSO NEW ENERGY 480C(HWB)60(182) output rank, 8 kW array size (17 panels), efficiency rating, and 600 V string limit.

Rank #4,809 / 21,677

### Top 22.6% STC Output

480.0 W STC (+95.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #2,585

### 22.22% Aperture Efficiency

Power density 222.2 W/m2 (2.31 percentage points above 19.91% CEC median). PTC/STC ratio: 94.6% (rank #2,348).

NEC 690.7 Limit

### 12 Panels Max @ -10 C (600 V)

Cold Voc reaches 47.27 V at -10 C (567.2 V string) and 48.34 V at -20 C (12 max).

 8 kW Reference Array

### 17 Panels = 8,160 W STC

Occupies 36.7 m2 (395 sq ft) producing 7,718 W PTC; NEC 690.8 OCPD floor is 22.79 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 43.52 * (1 + (-0.246/100) * (-10 - 25)) = 47.27 V | OCPD = 1.56 * 14.61 = 22.79 A

Inputs from CEC Modules.csv for PT LESSO NEW ENERGY 480C(HWB)60(182): Voc=43.52 V, beta_Voc=-0.246%/C, Isc=14.61 A, STC=480.0 W, Area=2.16 m2.

**Result:** 12 panels max on 600 V (567.2 V); 17 panels for 8 kW (395 sq ft).

## What Are the Published CEC Specifications for PT LESSO NEW ENERGY 480C(HWB)60(182)?

Complete CEC test sheet for PT LESSO NEW ENERGY 480C(HWB)60(182) including Isc (14.61 A), Voc (43.52 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for PT LESSO NEW ENERGY 480C(HWB)60(182).

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 480.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 454.0 W (94.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 43.52 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 14.61 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 35.48 V / 13.53 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.246 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 22.22% (2.16 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many PT LESSO NEW ENERGY 480C(HWB)60(182) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using PT LESSO NEW ENERGY 480C(HWB)60(182).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 13 | 6.24 kW | 302 sq ft | $1,562 | $2,641 |
| **8 kW Class** | 17 | 8.16 kW | 395 sq ft | $2,042 | $3,454 |
| **10 kW Class** | 21 | 10.08 kW | 488 sq ft | $2,523 | $4,266 |

## How Many PT LESSO NEW ENERGY 480C(HWB)60(182) Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for PT LESSO NEW ENERGY 480C(HWB)60(182) (43.52 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=43.52V and beta_Voc=-0.246%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 48.34 V | 12 panels | 580.1 V | 20 panels |
| **-10 C (14 F)** | 47.27 V | 12 panels | 567.2 V | 21 panels |
| **0 C (32 F)** | 46.2 V | 12 panels | 554.4 V | 21 panels |
| **25 C (77 F STC)** | 43.52 V | 13 panels | 565.8 V | 22 panels |

## Which Cross-Brand Solar Modules Compare Closest to PT LESSO NEW ENERGY 480C(HWB)60(182)?

Four comparable CEC modules such as Aptos Solar Technology LLC DNA-120-BFN10-480W-DG (480.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Aptos Solar Technology LLC DNA-120-BFN10-480W-DG**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-120-bfn10-480w-dg/) Aptos Solar Technology LLC | 480.0 W | Tie (0 W) | 42.61 V | 22.22% | 94.9% |
| [**Auxin Solar AXN10M485B**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m485b/) Auxin Solar | 485.0 W | +5.0 W | 43.98 V | 22.56% | 92.0% |
| [**Auxin Solar AXN10M485W**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m485w/) Auxin Solar | 485.0 W | +5.0 W | 43.98 V | 22.56% | 91.8% |
| [**Hanersun Energy Co Ltd HN18N-60HT485W**](https://epri-peac.com/solar-equipment/modules/hanersun-energy-co-ltd/hanersun-energy-co-ltd-hn18n-60ht485w/) Hanersun Energy Co Ltd | 485.0 W | +5.0 W | 43.0 V | 22.99% | 94.9% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for PT LESSO NEW ENERGY 480C(HWB)60(182)?

Evaluate PT LESSO NEW ENERGY 480C(HWB)60(182) (480.0 W STC, 43.52 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), PT LESSO NEW ENERGY 480C(HWB)60(182) reaches 48.34 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 17 panels for an 8 kW build require 395 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 17 panels (395 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of PT LESSO NEW ENERGY 480C(HWB)60(182) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### PT LESSO NEW ENERGY 480C(HWB)60(182) 8 kW Residential Fit

Needs 17 modules (395 sq ft) with a 25 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Aptos Solar Technology LLC DNA-120-BFN10-480W-DG.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 454.0 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PT LESSO NEW ENERGY 480C(HWB)60(182) by PT LESSO NEW ENERGY grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is PT LESSO NEW ENERGY 480C(HWB)60(182) PTC wattage (454.0 W) lower than STC (480.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 454.0 W PTC (94.6% retention) across PT LESSO NEW ENERGY 480C(HWB)60(182)'s 2.16 m2 aperture.

### Who should skip PT LESSO NEW ENERGY 480C(HWB)60(182) on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 17 PT LESSO NEW ENERGY 480C(HWB)60(182) panels (395 sq ft) leave unusable roof gaps vs. Aptos Solar Technology LLC DNA-120-BFN10-480W-DG.

### What is the 1,000 V commercial string limit for PT LESSO NEW ENERGY 480C(HWB)60(182)?

On 1,000 V commercial inverters at -10 C (47.27 V cold Voc), PT LESSO NEW ENERGY 480C(HWB)60(182) fits up to 21 panels per series string.

## Related Pages

Compare PT LESSO NEW ENERGY equipment, Aptos Solar Technology LLC DNA-120-BFN10-480W-DG specs, utility payback rates, and NEC string calculators alongside PT LESSO NEW ENERGY 480C(HWB)60(182).

[All PT LESSO NEW ENERGY Certified Solar Models](https://epri-peac.com/solar-equipment/brands/pt-lesso-new-energy/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From PT LESSO NEW ENERGY

- [All PT LESSO NEW ENERGY Specs](https://epri-peac.com/solar-equipment/brands/pt-lesso-new-energy/)
- [PT LESSO NEW ENERGY 580C(HBD)72(182)](https://epri-peac.com/solar-equipment/modules/pt-lesso-new-energy/pt-lesso-new-energy-580c-hbd-72-182/)
- [PT LESSO NEW ENERGY 580C(HWB)72(182)](https://epri-peac.com/solar-equipment/modules/pt-lesso-new-energy/pt-lesso-new-energy-580c-hwb-72-182/)
- [PT LESSO NEW ENERGY 550D(HBD)72(182)](https://epri-peac.com/solar-equipment/modules/pt-lesso-new-energy/pt-lesso-new-energy-550d-hbd-72-182/)
- [PT LESSO NEW ENERGY 435C(HWB)54(182)](https://epri-peac.com/solar-equipment/modules/pt-lesso-new-energy/pt-lesso-new-energy-435c-hwb-54-182/)
- [PT LESSO NEW ENERGY 430C(HBB)54(182)](https://epri-peac.com/solar-equipment/modules/pt-lesso-new-energy/pt-lesso-new-energy-430c-hbb-54-182/)