title: "PT JAYA ELECTRICAL ENERGY Specs (420.0W, 39.66V Voc)"
url: https://epri-peac.com/solar-equipment/modules/pt-jaya-electrical-energy/pt-jaya-electrical-energy-jayaegn420-108-b/
description: "CEC datasheet for PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B): 420.0W STC, 39.66V Voc, 20-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) — CEC Solar Module Specifications

Manufacturer: [**PT JAYA ELECTRICAL ENERGY**](https://epri-peac.com/solar-equipment/brands/pt-jaya-electrical-energy/) Registry: **CEC Verified Engineering Specification**

PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) is a 420.0 W STC (398.3 W PTC) Mono-c-Si solar module ranking #7,910 of 21,677 CEC listings (top 37.8%; higher than 62.2% of peers). It delivers 21.54% efficiency, 39.66 V Voc at 25 C, and 42.99 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 420.0 W

- **PTC Wattage** : 398.3 W

- **Voc @ 25C** : 39.66 V

- **Efficiency** : 21.54%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) Compare Against Peer CEC Listings?

How PT JAYA ELECTRICAL ENERGY PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) handles rooftop heat (398.3 W PTC), 8 kW sizing, and cold winter string voltage.

PT JAYA ELECTRICAL ENERGY builds the PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 215.4 W/m2 (1.63 percentage points above 19.91% CEC median). Compared against AE Solar GmbH AE420CMD-108BDE (420.0 W), this model holds strong 94.8% PTC-to-STC heat retention (#1,790 of 21,677). Lower 39.66 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 21.18 A overcurrent floor served by a 25 A breaker.

## Where Does PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) Fall Across Listed CEC Models?

Where PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) (420.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B)?

Percentile placement of PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) across power density (215.4 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B)?

Four critical engineering numbers homeowners and solar installers check first when reviewing PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) specifications.

Rank #7,910 / 21,677

### Top 37.8% STC Output

420.0 W STC (+35.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #4,253

### 21.54% Aperture Efficiency

Power density 215.4 W/m2 (1.63 percentage points above 19.91% CEC median). PTC/STC ratio: 94.8% (rank #1,790).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.99 V at -10 C (558.9 V string) and 43.94 V at -20 C (13 max).

 8 kW Reference Array

### 20 Panels = 8,400 W STC

Occupies 39.0 m2 (420 sq ft) producing 7,966 W PTC; NEC 690.8 OCPD floor is 21.18 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.66 * (1 + (-0.24/100) * (-10 - 25)) = 42.99 V | OCPD = 1.56 * 13.58 = 21.18 A

Inputs from CEC Modules.csv for PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B): Voc=39.66 V, beta_Voc=-0.24%/C, Isc=13.58 A, STC=420.0 W, Area=1.95 m2.

**Result:** 13 panels max on 600 V (558.9 V); 20 panels for 8 kW (420 sq ft).

## What Are the Published CEC Specifications for PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B)?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B).

Official California Energy Commission (NREL SAM) test parameters for PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B).

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 420.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 398.3 W (94.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 39.66 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.58 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 31.63 V / 13.28 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.24 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.54% (1.95 m2) | Array roof footprint density |
| **Cell Count & Technology** | 54 cells (Mono-c-Si) | Monofacial backsheet |

## How Many PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) (420.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 15 | 6.3 kW | 315 sq ft | $1,577 | $2,666 |
| **8 kW Class** | 20 | 8.4 kW | 420 sq ft | $2,102 | $3,555 |
| **10 kW Class** | 24 | 10.08 kW | 504 sq ft | $2,523 | $4,266 |

## How Many PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) Modules Fit in a Cold-Weather String?

Maximum series module counts for PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=39.66V and beta_Voc=-0.24%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 43.94 V | 13 panels | 571.2 V | 22 panels |
| **-10 C (14 F)** | 42.99 V | 13 panels | 558.9 V | 23 panels |
| **0 C (32 F)** | 42.04 V | 14 panels | 588.6 V | 23 panels |
| **25 C (77 F STC)** | 39.66 V | 15 panels | 594.9 V | 25 panels |

## Which Cross-Brand Solar Modules Compare Closest to PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B)?

Alternative CEC solar modules from competing brands near PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) (420.0 W), including AE Solar GmbH AE420CMD-108BDE.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**AE Solar GmbH AE420CMD-108BDE**](https://epri-peac.com/solar-equipment/modules/ae-solar-gmbh/ae-solar-gmbh-ae420cmd-108bde/) AE Solar GmbH | 420.0 W | Tie (0 W) | 39.7 V | 21.54% | 94.8% |
| [**DE SOLAR(S) PTE LTD DE420-108BG-182S-N/BB**](https://epri-peac.com/solar-equipment/modules/de-solar-s-pte-ltd/de-solar-s-pte-ltd-de420-108bg-182s-n-bb/) DE SOLAR(S) PTE LTD | 420.0 W | Tie (0 W) | 39.7 V | 21.54% | 94.8% |
| [**Aptos Solar Technology LLC DNA-108-MFN10-420W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-420w/) Aptos Solar Technology LLC | 420.0 W | Tie (0 W) | 38.5 V | 21.65% | 95.0% |
| [**Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-420**](https://epri-peac.com/solar-equipment/modules/elin-energy-sirius-pv/elin-energy-sirius-pv-elnsm54m-hc-lv-n-420/) Elin Energy (Sirius PV) | 420.0 W | Tie (0 W) | 38.5 V | 21.65% | 94.9% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B)?

Evaluate PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) (420.0 W STC, 39.66 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) reaches 43.94 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 420 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) 8 kW Residential Fit

Needs 20 modules (420 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare AE Solar GmbH AE420CMD-108BDE.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 398.3 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) by PT JAYA ELECTRICAL ENERGY grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B)?

Multiplying PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B)'s 13.58 A short-circuit current by 1.56 equals 21.18 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 42.99 V cold Voc at 14 F and handles 13.58 A Isc; string inverters cap PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) at 13 panels on 600 V.

### Is PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) rely on utility bill offset (~$2,102/yr at 8 kW) rather than 25D.

## Related Pages

Compare PT JAYA ELECTRICAL ENERGY equipment, AE Solar GmbH AE420CMD-108BDE specs, utility payback rates, and NEC string calculators alongside PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B).

[All PT JAYA ELECTRICAL ENERGY Certified Solar Models](https://epri-peac.com/solar-equipment/brands/pt-jaya-electrical-energy/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From PT JAYA ELECTRICAL ENERGY

- [All PT JAYA ELECTRICAL ENERGY Specs](https://epri-peac.com/solar-equipment/brands/pt-jaya-electrical-energy/)
- [PT JAYA ELECTRICAL ENERGY JAYAEGN585-144](https://epri-peac.com/solar-equipment/modules/pt-jaya-electrical-energy/pt-jaya-electrical-energy-jayaegn585-144/)
- [PT JAYA ELECTRICAL ENERGY JAYAEGN570-144](https://epri-peac.com/solar-equipment/modules/pt-jaya-electrical-energy/pt-jaya-electrical-energy-jayaegn570-144/)
- [PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B)](https://epri-peac.com/solar-equipment/modules/pt-jaya-electrical-energy/pt-jaya-electrical-energy-jayaegn435-108-b/)