title: "PT IDN SOLAR TECH NUSA144H-405MB Specs (405.0W, 49.8V Voc)"
url: https://epri-peac.com/solar-equipment/modules/pt-idn-solar-tech/pt-idn-solar-tech-nusa144h-405mb/
description: "CEC datasheet for PT IDN SOLAR TECH NUSA144H-405MB: 405.0W STC, 49.8V Voc, 20-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# PT IDN SOLAR TECH NUSA144H-405MB — CEC Solar Module Specifications

Manufacturer: [**PT IDN SOLAR TECH**](https://epri-peac.com/solar-equipment/brands/pt-idn-solar-tech/) Registry: **CEC Verified Engineering Specification**

PT IDN SOLAR TECH NUSA144H-405MB is a 405.0 W STC (378.3 W PTC) Mono-c-Si solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 20.15% efficiency, 49.8 V Voc at 25 C, and 55.36 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 405.0 W

- **PTC Wattage** : 378.3 W

- **Voc @ 25C** : 49.8 V

- **Efficiency** : 20.15%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does PT IDN SOLAR TECH NUSA144H-405MB Compare Against Peer CEC Listings?

How PT IDN SOLAR TECH PT IDN SOLAR TECH NUSA144H-405MB handles rooftop heat (378.3 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, PT IDN SOLAR TECH NUSA144H-405MB exhibits 10.32 A short-circuit current, requiring a 16.1 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #8,961 of 21,677 (5.0 W below the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 40.2 m2 for an 8 kW system (25 panels for 10 kW). Higher 49.8 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

## Where Does PT IDN SOLAR TECH NUSA144H-405MB Fall Across Listed CEC Models?

Where PT IDN SOLAR TECH NUSA144H-405MB (405.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define PT IDN SOLAR TECH NUSA144H-405MB?

Percentile placement of PT IDN SOLAR TECH NUSA144H-405MB across power density (201.5 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for PT IDN SOLAR TECH NUSA144H-405MB?

Four critical engineering numbers homeowners and solar installers check first when reviewing PT IDN SOLAR TECH NUSA144H-405MB specifications.

Rank #8,961 / 21,677

### Top 43.4% STC Output

405.0 W STC (+20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,939

### 20.15% Aperture Efficiency

Power density 201.5 W/m2 (0.24 percentage points above 19.91% CEC median). PTC/STC ratio: 93.4% (rank #7,716).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.36 V at -10 C (553.6 V string) and 56.95 V at -20 C (10 max).

 8 kW Reference Array

### 20 Panels = 8,100 W STC

Occupies 40.2 m2 (433 sq ft) producing 7,566 W PTC; NEC 690.8 OCPD floor is 16.1 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.8 * (1 + (-0.319/100) * (-10 - 25)) = 55.36 V | OCPD = 1.56 * 10.32 = 16.1 A

Inputs from CEC Modules.csv for PT IDN SOLAR TECH NUSA144H-405MB: Voc=49.8 V, beta_Voc=-0.319%/C, Isc=10.32 A, STC=405.0 W, Area=2.01 m2.

**Result:** 10 panels max on 600 V (553.6 V); 20 panels for 8 kW (433 sq ft).

## What Are the Published CEC Specifications for PT IDN SOLAR TECH NUSA144H-405MB?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for PT IDN SOLAR TECH NUSA144H-405MB.

Official California Energy Commission (NREL SAM) test parameters for PT IDN SOLAR TECH NUSA144H-405MB.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 405.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 378.3 W (93.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 49.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 10.32 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 41.5 V / 9.75 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.319 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.15% (2.01 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many PT IDN SOLAR TECH NUSA144H-405MB Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using PT IDN SOLAR TECH NUSA144H-405MB (405.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 15 | 6.08 kW | 325 sq ft | $1,522 | $2,573 |
| **8 kW Class** | 20 | 8.1 kW | 433 sq ft | $2,027 | $3,428 |
| **10 kW Class** | 25 | 10.12 kW | 541 sq ft | $2,533 | $4,283 |

## Which Sibling Wattage & Trim Variants Belong to This PT IDN SOLAR TECH Series?

All closely matched PT IDN SOLAR TECH wattages and cosmetic trims sharing the PT IDN SOLAR TECH NUSA144H-405MB architecture.

Sibling CEC listings grouped into the PT IDN SOLAR TECH NUSA144H-405MB wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **PT IDN SOLAR TECH NUSA144H-400MB** | 400.0 W | 373.5 W | 49.5 V | 41.3 V | 19.9% |
| **PT IDN SOLAR TECH NUSA144H-405MB** | 405.0 W | 378.3 W | 49.8 V | 41.5 V | 20.15% |
| **PT IDN SOLAR TECH NUSA144H-410MB** | 410.0 W | 383.1 W | 50.1 V | 41.8 V | 20.4% |

## How Many PT IDN SOLAR TECH NUSA144H-405MB Modules Fit in a Cold-Weather String?

Maximum series module counts for PT IDN SOLAR TECH NUSA144H-405MB from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=49.8V and beta_Voc=-0.319%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 56.95 V | 10 panels | 569.5 V | 17 panels |
| **-10 C (14 F)** | 55.36 V | 10 panels | 553.6 V | 18 panels |
| **0 C (32 F)** | 53.77 V | 11 panels | 591.5 V | 18 panels |
| **25 C (77 F STC)** | 49.8 V | 12 panels | 597.6 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to PT IDN SOLAR TECH NUSA144H-405MB?

Alternative CEC solar modules from competing brands near PT IDN SOLAR TECH NUSA144H-405MB (405.0 W), including Boviet Solar Technology Co Ltd BVM6612M-405L-H.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Boviet Solar Technology Co Ltd BVM6612M-405L-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-405l-h/) Boviet Solar Technology Co Ltd | 405.0 W | Tie (0 W) | 49.45 V | 20.35% | 93.3% |
| [**Boviet Solar Technology Co Ltd BVM6612M-405L-H-HC**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-405l-h-hc/) Boviet Solar Technology Co Ltd | 405.0 W | Tie (0 W) | 49.45 V | 19.95% | 93.6% |
| [**CSI Solar Co Ltd CS3U-405MS**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3u-405ms/) CSI Solar Co Ltd | 405.0 W | Tie (0 W) | 49.3 V | 21.09% | 93.0% |
| [**Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W**](https://epri-peac.com/solar-equipment/modules/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd-as-6m-hc-405w/) Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd | 405.0 W | Tie (0 W) | 49.2 V | 21.2% | 92.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for PT IDN SOLAR TECH NUSA144H-405MB?

Evaluate PT IDN SOLAR TECH NUSA144H-405MB (405.0 W STC, 49.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), PT IDN SOLAR TECH NUSA144H-405MB reaches 56.95 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 433 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (433 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of PT IDN SOLAR TECH NUSA144H-405MB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### PT IDN SOLAR TECH NUSA144H-405MB 8 kW Residential Fit

Needs 20 modules (433 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-405L-H.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 378.3 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PT IDN SOLAR TECH NUSA144H-405MB by PT IDN SOLAR TECH grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is PT IDN SOLAR TECH NUSA144H-405MB PTC wattage (378.3 W) lower than STC (405.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 378.3 W PTC (93.4% retention) across PT IDN SOLAR TECH NUSA144H-405MB's 2.01 m2 aperture.

### Who should skip PT IDN SOLAR TECH NUSA144H-405MB on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 PT IDN SOLAR TECH NUSA144H-405MB panels (433 sq ft) leave unusable roof gaps vs. Boviet Solar Technology Co Ltd BVM6612M-405L-H.

### What is the 1,000 V commercial string limit for PT IDN SOLAR TECH NUSA144H-405MB?

On 1,000 V commercial inverters at -10 C (55.36 V cold Voc), PT IDN SOLAR TECH NUSA144H-405MB fits up to 18 panels per series string.

## Related Pages

Compare PT IDN SOLAR TECH equipment, Boviet Solar Technology Co Ltd BVM6612M-405L-H specs, utility payback rates, and NEC string calculators alongside PT IDN SOLAR TECH NUSA144H-405MB.

[All PT IDN SOLAR TECH Certified Solar Models](https://epri-peac.com/solar-equipment/brands/pt-idn-solar-tech/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From PT IDN SOLAR TECH

- [All PT IDN SOLAR TECH Specs](https://epri-peac.com/solar-equipment/brands/pt-idn-solar-tech/)
- [PT IDN SOLAR TECH NUSA144H-555MD](https://epri-peac.com/solar-equipment/modules/pt-idn-solar-tech/pt-idn-solar-tech-nusa144h-555md/)
- [PT IDN SOLAR TECH NUSA144H-555MT](https://epri-peac.com/solar-equipment/modules/pt-idn-solar-tech/pt-idn-solar-tech-nusa144h-555mt/)
- [PT IDN SOLAR TECH NUSA144H-540MD](https://epri-peac.com/solar-equipment/modules/pt-idn-solar-tech/pt-idn-solar-tech-nusa144h-540md/)
- [PT IDN SOLAR TECH NUSA144H-540MT](https://epri-peac.com/solar-equipment/modules/pt-idn-solar-tech/pt-idn-solar-tech-nusa144h-540mt/)
- [PT IDN SOLAR TECH NUSA132H-505MT](https://epri-peac.com/solar-equipment/modules/pt-idn-solar-tech/pt-idn-solar-tech-nusa132h-505mt/)