title: "PT IDN SOLAR TECH NUSA144H-385M Specs (385.0W, 48.7V Voc)"
url: https://epri-peac.com/solar-equipment/modules/pt-idn-solar-tech/pt-idn-solar-tech-nusa144h-385m/
description: "CEC datasheet for PT IDN SOLAR TECH NUSA144H-385M: 385.0W STC, 48.7V Voc, 21-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# PT IDN SOLAR TECH NUSA144H-385M — CEC Solar Module Specifications

Manufacturer: [**PT IDN SOLAR TECH**](https://epri-peac.com/solar-equipment/brands/pt-idn-solar-tech/) Registry: **CEC Verified Engineering Specification**

PT IDN SOLAR TECH NUSA144H-385M is a 385.0 W STC (359.1 W PTC) Mono-c-Si solar module ranking #10,723 of 21,677 CEC listings (at all-CEC median; higher than 49.1% of peers). It delivers 19.15% efficiency, 48.7 V Voc at 25 C, and 54.14 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 385.0 W

- **PTC Wattage** : 359.1 W

- **Voc @ 25C** : 48.7 V

- **Efficiency** : 19.15%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does PT IDN SOLAR TECH NUSA144H-385M Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for PT IDN SOLAR TECH NUSA144H-385M (Mono-c-Si) residential solar systems.

Homeowners evaluating PT IDN SOLAR TECH NUSA144H-385M need 16 panels for 6 kW or 21 panels (454 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 21 panels (454 sq ft). Under NEC 690.7(A), beta_Voc (-0.319%/C) pushes open-circuit voltage to 54.14 V at 14 F and 55.69 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does PT IDN SOLAR TECH NUSA144H-385M Fall Across Listed CEC Models?

Comparison of PT IDN SOLAR TECH NUSA144H-385M (385.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define PT IDN SOLAR TECH NUSA144H-385M?

Relative ranking of PT IDN SOLAR TECH NUSA144H-385M across nameplate watts, 93.3% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for PT IDN SOLAR TECH NUSA144H-385M?

Summary of PT IDN SOLAR TECH NUSA144H-385M output rank, 8 kW array size (21 panels), efficiency rating, and 600 V string limit.

Rank #10,723 / 21,677

### 385.0 W STC · Higher Than 49.1%

385.0 W STC (equal to all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #13,087

### 19.15% Aperture Efficiency

Power density 191.5 W/m2 (0.76 percentage points below 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.14 V at -10 C (595.5 V string) and 55.69 V at -20 C (10 max).

 8 kW Reference Array

### 21 Panels = 8,085 W STC

Occupies 42.2 m2 (454 sq ft) producing 7,541 W PTC; NEC 690.8 OCPD floor is 15.69 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.7 * (1 + (-0.319/100) * (-10 - 25)) = 54.14 V | OCPD = 1.56 * 10.06 = 15.69 A

Inputs from CEC Modules.csv for PT IDN SOLAR TECH NUSA144H-385M: Voc=48.7 V, beta_Voc=-0.319%/C, Isc=10.06 A, STC=385.0 W, Area=2.01 m2.

**Result:** 11 panels max on 600 V (595.5 V); 21 panels for 8 kW (454 sq ft).

## What Are the Published CEC Specifications for PT IDN SOLAR TECH NUSA144H-385M?

Complete CEC test sheet for PT IDN SOLAR TECH NUSA144H-385M including Isc (10.06 A), Voc (48.7 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for PT IDN SOLAR TECH NUSA144H-385M.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 385.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 359.1 W (93.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 48.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 10.06 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 40.6 V / 9.49 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.319 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 19.15% (2.01 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many PT IDN SOLAR TECH NUSA144H-385M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using PT IDN SOLAR TECH NUSA144H-385M.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 16 | 6.16 kW | 346 sq ft | $1,542 | $2,607 |
| **8 kW Class** | 21 | 8.09 kW | 454 sq ft | $2,025 | $3,424 |
| **10 kW Class** | 26 | 10.01 kW | 563 sq ft | $2,505 | $4,236 |

## Which Sibling Wattage & Trim Variants Belong to This PT IDN SOLAR TECH Series?

Related PT IDN SOLAR TECH power steps and black/silver trims consolidated into this PT IDN SOLAR TECH NUSA144H-385M series guide.

Sibling CEC listings grouped into the PT IDN SOLAR TECH NUSA144H-385M wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **PT IDN SOLAR TECH NUSA144H-375M** | 375.0 W | 349.6 W | 48.3 V | 40.0 V | 18.66% |
| **PT IDN SOLAR TECH NUSA144H-380M** | 380.0 W | 354.4 W | 48.5 V | 40.3 V | 18.91% |
| **PT IDN SOLAR TECH NUSA144H-385M** | 385.0 W | 359.1 W | 48.7 V | 40.6 V | 19.15% |
| **PT IDN SOLAR TECH NUSA144H-390M** | 390.0 W | 363.9 W | 49.0 V | 40.8 V | 19.4% |
| **PT IDN SOLAR TECH NUSA144H-395M** | 395.0 W | 368.7 W | 49.2 V | 41.1 V | 19.65% |

## How Many PT IDN SOLAR TECH NUSA144H-385M Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for PT IDN SOLAR TECH NUSA144H-385M (48.7 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=48.7V and beta_Voc=-0.319%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 55.69 V | 10 panels | 556.9 V | 17 panels |
| **-10 C (14 F)** | 54.14 V | 11 panels | 595.5 V | 18 panels |
| **0 C (32 F)** | 52.58 V | 11 panels | 578.4 V | 19 panels |
| **25 C (77 F STC)** | 48.7 V | 12 panels | 584.4 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to PT IDN SOLAR TECH NUSA144H-385M?

Four comparable CEC modules such as EMMVEE Photovoltaic Power Private Limited E385M72 (385.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**EMMVEE Photovoltaic Power Private Limited E385M72**](https://epri-peac.com/solar-equipment/modules/emmvee-photovoltaic-power-private-limited/emmvee-photovoltaic-power-private-limited-e385m72/) EMMVEE Photovoltaic Power Private Limited | 385.0 W | Tie (0 W) | 48.9 V | 19.32% | 92.0% |
| [**Boviet Solar Technology Co Ltd BVM6612M-385-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-385-h/) Boviet Solar Technology Co Ltd | 385.0 W | Tie (0 W) | 48.5 V | 19.85% | 93.1% |
| [**Boviet Solar Technology Co Ltd BVM6612M-W5-385-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-w5-385-h/) Boviet Solar Technology Co Ltd | 385.0 W | Tie (0 W) | 48.5 V | 19.85% | 93.1% |
| [**Boviet Solar Technology Co Ltd BVM6612M-385L-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-385l-h/) Boviet Solar Technology Co Ltd | 385.0 W | Tie (0 W) | 48.45 V | 19.35% | 93.2% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for PT IDN SOLAR TECH NUSA144H-385M?

Evaluate PT IDN SOLAR TECH NUSA144H-385M (385.0 W STC, 48.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), PT IDN SOLAR TECH NUSA144H-385M reaches 55.69 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 454 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 21 panels (454 sq ft).
- 2026 tax credit baseline: cash residential installs of PT IDN SOLAR TECH NUSA144H-385M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### PT IDN SOLAR TECH NUSA144H-385M 8 kW Residential Fit

Needs 21 modules (454 sq ft) with a 20 A string OCPD, offsetting ~$2,025/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare EMMVEE Photovoltaic Power Private Limited E385M72.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 359.1 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PT IDN SOLAR TECH NUSA144H-385M by PT IDN SOLAR TECH grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is PT IDN SOLAR TECH NUSA144H-385M PTC wattage (359.1 W) lower than STC (385.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 359.1 W PTC (93.3% retention) across PT IDN SOLAR TECH NUSA144H-385M's 2.01 m2 aperture.

### Who should skip PT IDN SOLAR TECH NUSA144H-385M on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 21 PT IDN SOLAR TECH NUSA144H-385M panels (454 sq ft) leave unusable roof gaps vs. EMMVEE Photovoltaic Power Private Limited E385M72.

### What is the 1,000 V commercial string limit for PT IDN SOLAR TECH NUSA144H-385M?

On 1,000 V commercial inverters at -10 C (54.14 V cold Voc), PT IDN SOLAR TECH NUSA144H-385M fits up to 18 panels per series string.

## Related Pages

Compare PT IDN SOLAR TECH equipment, EMMVEE Photovoltaic Power Private Limited E385M72 specs, utility payback rates, and NEC string calculators alongside PT IDN SOLAR TECH NUSA144H-385M.

[All PT IDN SOLAR TECH Certified Solar Models](https://epri-peac.com/solar-equipment/brands/pt-idn-solar-tech/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From PT IDN SOLAR TECH

- [All PT IDN SOLAR TECH Specs](https://epri-peac.com/solar-equipment/brands/pt-idn-solar-tech/)
- [PT IDN SOLAR TECH NUSA144H-555MD](https://epri-peac.com/solar-equipment/modules/pt-idn-solar-tech/pt-idn-solar-tech-nusa144h-555md/)
- [PT IDN SOLAR TECH NUSA144H-555MT](https://epri-peac.com/solar-equipment/modules/pt-idn-solar-tech/pt-idn-solar-tech-nusa144h-555mt/)
- [PT IDN SOLAR TECH NUSA144H-540MD](https://epri-peac.com/solar-equipment/modules/pt-idn-solar-tech/pt-idn-solar-tech-nusa144h-540md/)
- [PT IDN SOLAR TECH NUSA144H-540MT](https://epri-peac.com/solar-equipment/modules/pt-idn-solar-tech/pt-idn-solar-tech-nusa144h-540mt/)
- [PT IDN SOLAR TECH NUSA132H-505MT](https://epri-peac.com/solar-equipment/modules/pt-idn-solar-tech/pt-idn-solar-tech-nusa132h-505mt/)