title: "PT Deltamas Solusindo SQF390M-72 Specs (390.0W, 48.16V Voc)"
url: https://epri-peac.com/solar-equipment/modules/pt-deltamas-solusindo/pt-deltamas-solusindo-sqf390m-72/
description: "CEC datasheet for PT Deltamas Solusindo SQF390M-72: 390.0W STC, 48.16V Voc, 21-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# PT Deltamas Solusindo SQF390M-72 — CEC Solar Module Specifications

Manufacturer: [**PT Deltamas Solusindo**](https://epri-peac.com/solar-equipment/brands/pt-deltamas-solusindo/) Registry: **CEC Verified Engineering Specification**

PT Deltamas Solusindo SQF390M-72 is a 390.0 W STC (366.4 W PTC) Mono-c-Si solar module ranking #10,321 of 21,677 CEC listings (top 49.5%; higher than 50.5% of peers). It delivers 19.4% efficiency, 48.16 V Voc at 25 C, and 52.07 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 390.0 W

- **PTC Wattage** : 366.4 W

- **Voc @ 25C** : 48.16 V

- **Efficiency** : 19.4%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does PT Deltamas Solusindo SQF390M-72 Compare Against Peer CEC Listings?

Solar engineering breakdown for PT Deltamas Solusindo SQF390M-72: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from PT Deltamas Solusindo and peers, PT Deltamas Solusindo SQF390M-72 stands 20.0 W below the 410.0 W Mono-c-Si median and strong 93.9% PTC-to-STC heat retention (#5,210 of 21,677). Sizing 6 kW (16 panels) to 10 kW (26 panels) yields $1,562-$2,538/yr in baseline US bill offset. Higher 48.16 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).

## Where Does PT Deltamas Solusindo SQF390M-72 Fall Across Listed CEC Models?

Distribution marker showing PT Deltamas Solusindo SQF390M-72 (390.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define PT Deltamas Solusindo SQF390M-72?

Dataset percentiles tracking PT Deltamas Solusindo SQF390M-72 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for PT Deltamas Solusindo SQF390M-72?

Benchmark highlights for PT Deltamas Solusindo SQF390M-72 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #10,321 / 21,677

### Top 49.5% STC Output

390.0 W STC (+5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #12,426

### 19.4% Aperture Efficiency

Power density 194.0 W/m2 (0.51 percentage points below 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.07 V at -10 C (572.8 V string) and 53.19 V at -20 C (11 max).

 8 kW Reference Array

### 21 Panels = 8,190 W STC

Occupies 42.2 m2 (454 sq ft) producing 7,694 W PTC; NEC 690.8 OCPD floor is 15.85 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.16 * (1 + (-0.232/100) * (-10 - 25)) = 52.07 V | OCPD = 1.56 * 10.16 = 15.85 A

Inputs from CEC Modules.csv for PT Deltamas Solusindo SQF390M-72: Voc=48.16 V, beta_Voc=-0.232%/C, Isc=10.16 A, STC=390.0 W, Area=2.01 m2.

**Result:** 11 panels max on 600 V (572.8 V); 21 panels for 8 kW (454 sq ft).

## What Are the Published CEC Specifications for PT Deltamas Solusindo SQF390M-72?

Official CEC datasheet figures for PT Deltamas Solusindo SQF390M-72 (Mono-c-Si) used in utility interconnection and permit reviews. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Official California Energy Commission (NREL SAM) test parameters for PT Deltamas Solusindo SQF390M-72.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 390.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 366.4 W (93.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 48.16 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 10.16 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 40.68 V / 9.59 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.232 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 19.4% (2.01 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many PT Deltamas Solusindo SQF390M-72 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many PT Deltamas Solusindo SQF390M-72 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 16 | 6.24 kW | 346 sq ft | $1,562 | $2,641 |
| **8 kW Class** | 21 | 8.19 kW | 454 sq ft | $2,050 | $3,466 |
| **10 kW Class** | 26 | 10.14 kW | 563 sq ft | $2,538 | $4,292 |

## Which Sibling Wattage & Trim Variants Belong to This PT Deltamas Solusindo Series?

Consolidated PT Deltamas Solusindo wattage variants sharing the PT Deltamas Solusindo SQF390M-72 mechanical and cell layout. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sibling CEC listings grouped into the PT Deltamas Solusindo SQF390M-72 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **PT Deltamas Solusindo SQF380M-72** | 380.0 W | 356.8 W | 48.16 V | 39.7 V | 18.91% |
| **PT Deltamas Solusindo SQF385M-72** | 385.0 W | 361.6 W | 48.16 V | 40.16 V | 19.15% |
| **PT Deltamas Solusindo SQF390M-72** | 390.0 W | 366.4 W | 48.16 V | 40.68 V | 19.4% |
| **PT Deltamas Solusindo SQF395M-72** | 395.0 W | 371.2 W | 48.88 V | 40.8 V | 19.65% |

## How Many PT Deltamas Solusindo SQF390M-72 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on PT Deltamas Solusindo SQF390M-72 (52.07 V at 14 F).

Computed from Voc=48.16V and beta_Voc=-0.232%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 53.19 V | 11 panels | 585.1 V | 18 panels |
| **-10 C (14 F)** | 52.07 V | 11 panels | 572.8 V | 19 panels |
| **0 C (32 F)** | 50.95 V | 11 panels | 560.5 V | 19 panels |
| **25 C (77 F STC)** | 48.16 V | 12 panels | 577.9 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to PT Deltamas Solusindo SQF390M-72?

Competing CEC solar panels closest to PT Deltamas Solusindo SQF390M-72 in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS3U-390MS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS3U-390MS**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3u-390ms/) CSI Solar Co Ltd | 390.0 W | Tie (0 W) | 48.2 V | 20.31% | 93.2% |
| [**CSI Solar Co Ltd CS3W-390P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3w-390p/) CSI Solar Co Ltd | 390.0 W | Tie (0 W) | 46.8 V | 18.22% | 92.4% |
| [**AXITEC AC-385MH/144S**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-385mh-144s/) AXITEC | 385.0 W | -5.0 W | 48.0 V | 19.41% | 92.9% |
| [**AXITEC AC-385MH/144V**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-385mh-144v/) AXITEC | 385.0 W | -5.0 W | 48.0 V | 19.41% | 92.9% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for PT Deltamas Solusindo SQF390M-72?

Evaluate PT Deltamas Solusindo SQF390M-72 (390.0 W STC, 48.16 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), PT Deltamas Solusindo SQF390M-72 reaches 53.19 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 454 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (454 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of PT Deltamas Solusindo SQF390M-72 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### PT Deltamas Solusindo SQF390M-72 8 kW Residential Fit

Needs 21 modules (454 sq ft) with a 20 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS3U-390MS.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 366.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PT Deltamas Solusindo SQF390M-72 by PT Deltamas Solusindo grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for PT Deltamas Solusindo SQF390M-72?

Multiplying PT Deltamas Solusindo SQF390M-72's 10.16 A short-circuit current by 1.56 equals 15.85 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

### Can PT Deltamas Solusindo SQF390M-72 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 52.07 V cold Voc at 14 F and handles 10.16 A Isc; string inverters cap PT Deltamas Solusindo SQF390M-72 at 11 panels on 600 V.

### Is PT Deltamas Solusindo SQF390M-72 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of PT Deltamas Solusindo SQF390M-72 rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.

## Related Pages

Compare PT Deltamas Solusindo equipment, CSI Solar Co Ltd CS3U-390MS specs, utility payback rates, and NEC string calculators alongside PT Deltamas Solusindo SQF390M-72.

[All PT Deltamas Solusindo Certified Solar Models](https://epri-peac.com/solar-equipment/brands/pt-deltamas-solusindo/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From PT Deltamas Solusindo

- [All PT Deltamas Solusindo Specs](https://epri-peac.com/solar-equipment/brands/pt-deltamas-solusindo/)
- [PT Deltamas Solusindo SQF400M-72](https://epri-peac.com/solar-equipment/modules/pt-deltamas-solusindo/pt-deltamas-solusindo-sqf400m-72/)