title: "Prism Solar Technologies Inc Specs #3 | WireAndSun"
url: https://epri-peac.com/solar-equipment/modules/prism-solar-technologies-inc/prism-solar-technologies-inc-pst-420w-m72hbi/
description: "CEC datasheet for Prism Solar Technologies Inc PST-420W-m72HBi: 420.0W STC, 49.8V Voc, 20-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# Prism Solar Technologies Inc PST-420W-m72HBi — CEC Solar Module Specifications

Manufacturer: [**Prism Solar Technologies Inc**](https://epri-peac.com/solar-equipment/brands/prism-solar-technologies-inc/) Registry: **CEC Verified Engineering Specification**

Prism Solar Technologies Inc PST-420W-m72HBi is a 420.0 W STC (392.3 W PTC) Mono-c-Si solar module ranking #7,910 of 21,677 CEC listings (top 37.8%; higher than 62.2% of peers). It delivers 19.0% efficiency, 49.8 V Voc at 25 C, and 54.94 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 420.0 W

- **PTC Wattage** : 392.3 W

- **Voc @ 25C** : 49.8 V

- **Efficiency** : 19.0%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Prism Solar Technologies Inc PST-420W-m72HBi Compare Against Peer CEC Listings?

How Prism Solar Technologies Inc Prism Solar Technologies Inc PST-420W-m72HBi handles rooftop heat (392.3 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Prism Solar Technologies Inc PST-420W-m72HBi exhibits 11.27 A short-circuit current, requiring a 17.58 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #7,910 of 21,677 (10.0 W above the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 44.2 m2 for an 8 kW system (24 panels for 10 kW). Higher 49.8 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

## Where Does Prism Solar Technologies Inc PST-420W-m72HBi Fall Across Listed CEC Models?

Where Prism Solar Technologies Inc PST-420W-m72HBi (420.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Prism Solar Technologies Inc PST-420W-m72HBi?

Percentile placement of Prism Solar Technologies Inc PST-420W-m72HBi across power density (190.0 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Prism Solar Technologies Inc PST-420W-m72HBi?

Four critical engineering numbers homeowners and solar installers check first when reviewing Prism Solar Technologies Inc PST-420W-m72HBi specifications.

Rank #7,910 / 21,677

### Top 37.8% STC Output

420.0 W STC (+35.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #13,454

### 19.0% Aperture Efficiency

Power density 190.0 W/m2 (0.91 percentage points below 19.91% CEC median). PTC/STC ratio: 93.4% (rank #7,716).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.94 V at -10 C (549.4 V string) and 56.41 V at -20 C (10 max).

 8 kW Reference Array

### 20 Panels = 8,400 W STC

Occupies 44.2 m2 (476 sq ft) producing 7,846 W PTC; NEC 690.8 OCPD floor is 17.58 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.8 * (1 + (-0.295/100) * (-10 - 25)) = 54.94 V | OCPD = 1.56 * 11.27 = 17.58 A

Inputs from CEC Modules.csv for Prism Solar Technologies Inc PST-420W-m72HBi: Voc=49.8 V, beta_Voc=-0.295%/C, Isc=11.27 A, STC=420.0 W, Area=2.21 m2.

**Result:** 10 panels max on 600 V (549.4 V); 20 panels for 8 kW (476 sq ft).

## What Are the Published CEC Specifications for Prism Solar Technologies Inc PST-420W-m72HBi?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Prism Solar Technologies Inc PST-420W-m72HBi.

Official California Energy Commission (NREL SAM) test parameters for Prism Solar Technologies Inc PST-420W-m72HBi.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 420.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 392.3 W (93.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 49.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 11.27 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 41.2 V / 10.19 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.295 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 19.0% (2.21 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Prism Solar Technologies Inc PST-420W-m72HBi Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Prism Solar Technologies Inc PST-420W-m72HBi (420.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 15 | 6.3 kW | 357 sq ft | $1,577 | $2,666 |
| **8 kW Class** | 20 | 8.4 kW | 476 sq ft | $2,102 | $3,555 |
| **10 kW Class** | 24 | 10.08 kW | 571 sq ft | $2,523 | $4,266 |

## Which Sibling Wattage & Trim Variants Belong to This Prism Solar Technologies Inc Series?

All closely matched Prism Solar Technologies Inc wattages and cosmetic trims sharing the Prism Solar Technologies Inc PST-420W-m72HBi architecture.

Sibling CEC listings grouped into the Prism Solar Technologies Inc PST-420W-m72HBi wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Prism Solar Technologies Inc PST-415W-m72HBi** | 415.0 W | 387.5 W | 49.6 V | 41.15 V | 18.78% |
| **Prism Solar Technologies Inc PST-420W-m72HBi** | 420.0 W | 392.3 W | 49.8 V | 41.2 V | 19.0% |

## How Many Prism Solar Technologies Inc PST-420W-m72HBi Modules Fit in a Cold-Weather String?

Maximum series module counts for Prism Solar Technologies Inc PST-420W-m72HBi from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=49.8V and beta_Voc=-0.295%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 56.41 V | 10 panels | 564.1 V | 17 panels |
| **-10 C (14 F)** | 54.94 V | 10 panels | 549.4 V | 18 panels |
| **0 C (32 F)** | 53.47 V | 11 panels | 588.2 V | 18 panels |
| **25 C (77 F STC)** | 49.8 V | 12 panels | 597.6 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to Prism Solar Technologies Inc PST-420W-m72HBi?

Alternative CEC solar modules from competing brands near Prism Solar Technologies Inc PST-420W-m72HBi (420.0 W), including CSI Solar Co Ltd CS3W-420MB-AG.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS3W-420MB-AG**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3w-420mb-ag/) CSI Solar Co Ltd | 420.0 W | Tie (0 W) | 47.9 V | 19.44% | 92.7% |
| [**Aptos Solar Technology LLC DNA-144-BF23-410W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-144-bf23-410w/) Aptos Solar Technology LLC | 410.0 W | -10.0 W | 48.56 V | 21.03% | 93.4% |
| [**Boviet Solar Technology Co Ltd BVM6612M-405L-H-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-405l-h-bf/) Boviet Solar Technology Co Ltd | 405.0 W | -15.0 W | 49.45 V | 20.15% | 93.4% |
| [**Boviet Solar Technology Co Ltd BVM6612M-405L-H-BF-DG**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-405l-h-bf-dg/) Boviet Solar Technology Co Ltd | 405.0 W | -15.0 W | 49.45 V | 20.05% | 93.7% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Prism Solar Technologies Inc PST-420W-m72HBi?

Evaluate Prism Solar Technologies Inc PST-420W-m72HBi (420.0 W STC, 49.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Prism Solar Technologies Inc PST-420W-m72HBi reaches 56.41 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 476 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (476 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Prism Solar Technologies Inc PST-420W-m72HBi carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Prism Solar Technologies Inc PST-420W-m72HBi 8 kW Residential Fit

Needs 20 modules (476 sq ft) with a 20 A string OCPD, offsetting ~$2,102/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare CSI Solar Co Ltd CS3W-420MB-AG.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 392.3 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Prism Solar Technologies Inc PST-420W-m72HBi by Prism Solar Technologies Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Prism Solar Technologies Inc PST-420W-m72HBi PTC wattage (392.3 W) lower than STC (420.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 392.3 W PTC (93.4% retention) across Prism Solar Technologies Inc PST-420W-m72HBi's 2.21 m2 aperture.

### Who should skip Prism Solar Technologies Inc PST-420W-m72HBi on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 Prism Solar Technologies Inc PST-420W-m72HBi panels (476 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS3W-420MB-AG.

### What is the 1,000 V commercial string limit for Prism Solar Technologies Inc PST-420W-m72HBi?

On 1,000 V commercial inverters at -10 C (54.94 V cold Voc), Prism Solar Technologies Inc PST-420W-m72HBi fits up to 18 panels per series string.

## Related Pages

Compare Prism Solar Technologies Inc equipment, CSI Solar Co Ltd CS3W-420MB-AG specs, utility payback rates, and NEC string calculators alongside Prism Solar Technologies Inc PST-420W-m72HBi.

[All Prism Solar Technologies Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/prism-solar-technologies-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Prism Solar Technologies Inc

- [All Prism Solar Technologies Inc Specs](https://epri-peac.com/solar-equipment/brands/prism-solar-technologies-inc/)
- [Prism Solar Technologies Inc PST-535W-M72H-M10](https://epri-peac.com/solar-equipment/modules/prism-solar-technologies-inc/prism-solar-technologies-inc-pst-535w-m72h-m10/)
- [Prism Solar Technologies Inc PST-450W-M60H-M10](https://epri-peac.com/solar-equipment/modules/prism-solar-technologies-inc/prism-solar-technologies-inc-pst-450w-m60h-m10/)
- [Prism Solar Technologies Inc PST-445W-M60H-M10](https://epri-peac.com/solar-equipment/modules/prism-solar-technologies-inc/prism-solar-technologies-inc-pst-445w-m60h-m10/)
- [Prism Solar Technologies Inc PST-435W-m72H](https://epri-peac.com/solar-equipment/modules/prism-solar-technologies-inc/prism-solar-technologies-inc-pst-435w-m72h/)
- [Prism Solar Technologies Inc PST-435W-m72HB](https://epri-peac.com/solar-equipment/modules/prism-solar-technologies-inc/prism-solar-technologies-inc-pst-435w-m72hb/)