title: "Philadelphia Solar Specs (580.0W, 51.07V Voc)"
url: https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-mng144-hcbf-570w/
description: "CEC datasheet for Philadelphia Solar PS-MNG144(HCBF)-570W: 580.0W STC, 51.07V Voc, 14-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Philadelphia Solar PS-MNG144(HCBF)-570W — CEC Solar Module Specifications

Manufacturer: [**Philadelphia Solar**](https://epri-peac.com/solar-equipment/brands/philadelphia-solar/) Registry: **CEC Verified Engineering Specification**

Philadelphia Solar PS-MNG144(HCBF)-570W is a 580.0 W STC (550.3 W PTC) Mono-c-Si solar module ranking #1,885 of 21,677 CEC listings (top 9.4%; higher than 90.6% of peers). It delivers 22.48% efficiency, 51.07 V Voc at 25 C, and 55.13 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 580.0 W

- **PTC Wattage** : 550.3 W

- **Voc @ 25C** : 51.07 V

- **Efficiency** : 22.48%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Philadelphia Solar PS-MNG144(HCBF)-570W Compare Against Peer CEC Listings?

Solar engineering breakdown for Philadelphia Solar PS-MNG144(HCBF)-570W: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 580.0 W STC and 550.3 W PTC, Philadelphia Solar PS-MNG144(HCBF)-570W sits +195.0 W vs all-CEC median (top 9.4%; higher than 90.6% of peers) among 21,677 listed modules. Power density reaches 224.8 W/m2 (2.57 percentage points above 19.91% CEC median). Higher 51.07 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 18 panels in series. Alternative peer Gautam Solar Pvt Ltd G2G1740-HAD rates 580.0 W.

## Where Does Philadelphia Solar PS-MNG144(HCBF)-570W Fall Across Listed CEC Models?

Distribution marker showing Philadelphia Solar PS-MNG144(HCBF)-570W (580.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define Philadelphia Solar PS-MNG144(HCBF)-570W?

Dataset percentiles tracking Philadelphia Solar PS-MNG144(HCBF)-570W power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for Philadelphia Solar PS-MNG144(HCBF)-570W?

Benchmark highlights for Philadelphia Solar PS-MNG144(HCBF)-570W covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #1,885 / 21,677

### Top 9.4% STC Output

580.0 W STC (+195.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #2,050

### 22.48% Aperture Efficiency

Power density 224.8 W/m2 (2.57 percentage points above 19.91% CEC median). PTC/STC ratio: 94.9% (rank #1,466).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.13 V at -10 C (551.3 V string) and 56.29 V at -20 C (10 max).

 8 kW Reference Array

### 14 Panels = 8,120 W STC

Occupies 36.1 m2 (389 sq ft) producing 7,704 W PTC; NEC 690.8 OCPD floor is 22.23 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 51.07 * (1 + (-0.227/100) * (-10 - 25)) = 55.13 V | OCPD = 1.56 * 14.25 = 22.23 A

Inputs from CEC Modules.csv for Philadelphia Solar PS-MNG144(HCBF)-570W: Voc=51.07 V, beta_Voc=-0.227%/C, Isc=14.25 A, STC=580.0 W, Area=2.58 m2.

**Result:** 10 panels max on 600 V (551.3 V); 14 panels for 8 kW (389 sq ft).

## What Are the Published CEC Specifications for Philadelphia Solar PS-MNG144(HCBF)-570W?

Official CEC datasheet figures for Philadelphia Solar PS-MNG144(HCBF)-570W (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Philadelphia Solar PS-MNG144(HCBF)-570W.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 580.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 550.3 W (94.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 51.07 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 14.25 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 42.29 V / 13.48 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.227 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 22.48% (2.58 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Philadelphia Solar PS-MNG144(HCBF)-570W Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Philadelphia Solar PS-MNG144(HCBF)-570W modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 11 | 6.38 kW | 305 sq ft | $1,597 | $2,700 |
| **8 kW Class** | 14 | 8.12 kW | 389 sq ft | $2,032 | $3,437 |
| **10 kW Class** | 18 | 10.44 kW | 500 sq ft | $2,613 | $4,418 |

## Which Sibling Wattage & Trim Variants Belong to This Philadelphia Solar Series?

Consolidated Philadelphia Solar wattage variants sharing the Philadelphia Solar PS-MNG144(HCBF)-570W mechanical and cell layout. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sibling CEC listings grouped into the Philadelphia Solar PS-MNG144(HCBF)-570W wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Philadelphia Solar PS-MNG144(HCBF)-555W** | 580.0 W | 550.3 W | 50.47 V | 41.83 V | 22.48% |
| **Philadelphia Solar PS-MNG144(HCBF)-560W** | 580.0 W | 550.3 W | 50.67 V | 41.95 V | 22.48% |
| **Philadelphia Solar PS-MNG144(HCBF)-565W** | 580.0 W | 550.3 W | 50.87 V | 42.14 V | 22.48% |
| **Philadelphia Solar PS-MNG144(HCBF)-570W** | 580.0 W | 550.3 W | 51.07 V | 42.29 V | 22.48% |
| **Philadelphia Solar PS-MNG144(HCBF)-575W** | 580.0 W | 550.3 W | 51.27 V | 42.44 V | 22.48% |
| **Philadelphia Solar PS-MNG144(HCBF)-580W** | 580.0 W | 550.3 W | 51.47 V | 42.59 V | 22.48% |

## How Many Philadelphia Solar PS-MNG144(HCBF)-570W Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Philadelphia Solar PS-MNG144(HCBF)-570W (55.13 V at 14 F).

Computed from Voc=51.07V and beta_Voc=-0.227%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 56.29 V | 10 panels | 562.9 V | 17 panels |
| **-10 C (14 F)** | 55.13 V | 10 panels | 551.3 V | 18 panels |
| **0 C (32 F)** | 53.97 V | 11 panels | 593.7 V | 18 panels |
| **25 C (77 F STC)** | 51.07 V | 11 panels | 561.8 V | 19 panels |

## Which Cross-Brand Solar Modules Compare Closest to Philadelphia Solar PS-MNG144(HCBF)-570W?

Competing CEC solar panels closest to Philadelphia Solar PS-MNG144(HCBF)-570W in nameplate wattage and Voc, starting with Gautam Solar Pvt Ltd G2G1740-HAD.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Gautam Solar Pvt Ltd G2G1740-HAD**](https://epri-peac.com/solar-equipment/modules/gautam-solar-pvt-ltd/gautam-solar-pvt-ltd-g2g1740-had/) Gautam Solar Pvt Ltd | 580.0 W | Tie (0 W) | 51.04 V | 22.59% | 95.1% |
| [**Gautam Solar Pvt Ltd G2X1740N-UHAD**](https://epri-peac.com/solar-equipment/modules/gautam-solar-pvt-ltd/gautam-solar-pvt-ltd-g2x1740n-uhad/) Gautam Solar Pvt Ltd | 580.0 W | Tie (0 W) | 51.04 V | 22.57% | 94.9% |
| [**EMMVEE Photovoltaic Power Private Limited E580HCBT144-T**](https://epri-peac.com/solar-equipment/modules/emmvee-photovoltaic-power-private-limited/emmvee-photovoltaic-power-private-limited-e580hcbt144-t/) EMMVEE Photovoltaic Power Private Limited | 580.0 W | Tie (0 W) | 51.47 V | 22.66% | 94.6% |
| [**Gautam Solar Pvt Ltd G2G1755-HAD**](https://epri-peac.com/solar-equipment/modules/gautam-solar-pvt-ltd/gautam-solar-pvt-ltd-g2g1755-had/) Gautam Solar Pvt Ltd | 585.0 W | +5.0 W | 51.19 V | 22.79% | 95.1% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Philadelphia Solar PS-MNG144(HCBF)-570W?

Evaluate Philadelphia Solar PS-MNG144(HCBF)-570W (580.0 W STC, 51.07 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Philadelphia Solar PS-MNG144(HCBF)-570W reaches 56.29 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 389 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Philadelphia Solar PS-MNG144(HCBF)-570W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Philadelphia Solar PS-MNG144(HCBF)-570W 8 kW Residential Fit

Needs 14 modules (389 sq ft) with a 25 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Gautam Solar Pvt Ltd G2G1740-HAD.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 550.3 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Philadelphia Solar PS-MNG144(HCBF)-570W by Philadelphia Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Philadelphia Solar PS-MNG144(HCBF)-570W panels fit on a 600 V winter solar string?

At -10 C (14 F), Philadelphia Solar PS-MNG144(HCBF)-570W cold Voc rises from 51.07 V to 55.13 V (beta_Voc -0.227%/C), capping a 600 V string at 10 panels (551.3 V).

### How much roof area does an 8 kW array of Philadelphia Solar PS-MNG144(HCBF)-570W need?

An 8 kW DC system uses 14 Philadelphia Solar PS-MNG144(HCBF)-570W modules (8,120 W STC / 7,704 W PTC), covering roughly 389 sq ft and saving ~$2,032/yr at 18.54 c/kWh.

### How does Philadelphia Solar PS-MNG144(HCBF)-570W compare against Gautam Solar Pvt Ltd G2G1740-HAD?

Philadelphia Solar PS-MNG144(HCBF)-570W outputs 580.0 W STC (51.07 V Voc, rank #1,885 of 21,677), while Gautam Solar Pvt Ltd G2G1740-HAD delivers 580.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Philadelphia Solar equipment, Gautam Solar Pvt Ltd G2G1740-HAD specs, utility payback rates, and NEC string calculators alongside Philadelphia Solar PS-MNG144(HCBF)-570W.

[All Philadelphia Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/philadelphia-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Philadelphia Solar

- [All Philadelphia Solar Specs](https://epri-peac.com/solar-equipment/brands/philadelphia-solar/)
- [Philadelphia Solar PS-MNB156(HCBF)-650W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-mnb156-hcbf-650w/)
- [Philadelphia Solar PS-MNB156(HCBF)-635W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-mnb156-hcbf-635w/)
- [Philadelphia Solar PS-MNB156(HCBF)-620W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-mnb156-hcbf-620w/)
- [Philadelphia Solar PS-M156(HC)-605W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-m156-hc-605w/)
- [Philadelphia Solar PS-M156(HCBF)-GG-605W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-m156-hcbf-gg-605w/)