Philadelphia Solar PS-MNB156(HCBF)-620W is a 620.0 W STC (584.5 W PTC) Mono-c-Si solar module ranking #934 of 21,677 CEC listings (top 4.7%; higher than 95.3% of peers). It delivers 22.22% efficiency, 55.65 V Voc at 25 C, and 60.01 V cold Voc at -10 C (9 panels max per 600 V string).

- **STC Wattage** : 620.0 W

- **PTC Wattage** : 584.5 W

- **Voc @ 25C** : 55.65 V

- **Efficiency** : 22.22%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Philadelphia Solar PS-MNB156(HCBF)-620W Compare Against Peer CEC Listings?

How Philadelphia Solar Philadelphia Solar PS-MNB156(HCBF)-620W handles rooftop heat (584.5 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Philadelphia Solar PS-MNB156(HCBF)-620W exhibits 14.02 A short-circuit current, requiring a 21.87 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #934 of 21,677 (210.0 W above the 410.0 W Mono-c-Si median), this large-format commercial and ground-mount module covers 36.3 m2 for an 8 kW system (17 panels for 10 kW). Higher 55.65 V open-circuit voltage caps 600 V residential strings at 9 panels at 14 F (-10 C).

## Where Does Philadelphia Solar PS-MNB156(HCBF)-620W Fall Across Listed CEC Models?

Where Philadelphia Solar PS-MNB156(HCBF)-620W (620.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Philadelphia Solar PS-MNB156(HCBF)-620W?

Percentile placement of Philadelphia Solar PS-MNB156(HCBF)-620W across power density (222.2 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Philadelphia Solar PS-MNB156(HCBF)-620W?

Four critical engineering numbers homeowners and solar installers check first when reviewing Philadelphia Solar PS-MNB156(HCBF)-620W specifications.

Rank #934 / 21,677

### Top 4.7% STC Output

620.0 W STC (+235.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #2,585

### 22.22% Aperture Efficiency

Power density 222.2 W/m2 (2.31 percentage points above 19.91% CEC median). PTC/STC ratio: 94.3% (rank #3,231).

NEC 690.7 Limit

### 9 Panels Max @ -10 C (600 V)

Cold Voc reaches 60.01 V at -10 C (540.1 V string) and 61.26 V at -20 C (9 max).

 8 kW Reference Array

### 13 Panels = 8,060 W STC

Occupies 36.3 m2 (390 sq ft) producing 7,598 W PTC; NEC 690.8 OCPD floor is 21.87 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 55.65 * (1 + (-0.224/100) * (-10 - 25)) = 60.01 V | OCPD = 1.56 * 14.02 = 21.87 A

Inputs from CEC Modules.csv for Philadelphia Solar PS-MNB156(HCBF)-620W: Voc=55.65 V, beta_Voc=-0.224%/C, Isc=14.02 A, STC=620.0 W, Area=2.79 m2.

**Result:** 9 panels max on 600 V (540.1 V); 13 panels for 8 kW (390 sq ft).

## What Are the Published CEC Specifications for Philadelphia Solar PS-MNB156(HCBF)-620W?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Philadelphia Solar PS-MNB156(HCBF)-620W.

Official California Energy Commission (NREL SAM) test parameters for Philadelphia Solar PS-MNB156(HCBF)-620W.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 620.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 584.5 W (94.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 55.65 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 14.02 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 46.75 V / 13.25 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.224 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 22.22% (2.79 m2) | Array roof footprint density |
| **Cell Count & Technology** | 78 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Philadelphia Solar PS-MNB156(HCBF)-620W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Philadelphia Solar PS-MNB156(HCBF)-620W (620.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 10 | 6.2 kW | 300 sq ft | $1,552 | $2,624 |
| **8 kW Class** | 13 | 8.06 kW | 390 sq ft | $2,017 | $3,411 |
| **10 kW Class** | 17 | 10.54 kW | 511 sq ft | $2,638 | $4,461 |

## Which Sibling Wattage & Trim Variants Belong to This Philadelphia Solar Series?

All closely matched Philadelphia Solar wattages and cosmetic trims sharing the Philadelphia Solar PS-MNB156(HCBF)-620W architecture. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Sibling CEC listings grouped into the Philadelphia Solar PS-MNB156(HCBF)-620W wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Philadelphia Solar PS-MNB156(HCBF)-615W** | 615.0 W | 579.7 W | 55.5 V | 46.48 V | 22.04% |
| **Philadelphia Solar PS-MNB156(HCBF)-620W** | 620.0 W | 584.5 W | 55.65 V | 46.75 V | 22.22% |

## How Many Philadelphia Solar PS-MNB156(HCBF)-620W Modules Fit in a Cold-Weather String?

Maximum series module counts for Philadelphia Solar PS-MNB156(HCBF)-620W from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=55.65V and beta_Voc=-0.224%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 61.26 V | 9 panels | 551.3 V | 16 panels |
| **-10 C (14 F)** | 60.01 V | 9 panels | 540.1 V | 16 panels |
| **0 C (32 F)** | 58.77 V | 10 panels | 587.7 V | 17 panels |
| **25 C (77 F STC)** | 55.65 V | 10 panels | 556.5 V | 17 panels |

## Which Cross-Brand Solar Modules Compare Closest to Philadelphia Solar PS-MNB156(HCBF)-620W?

Alternative CEC solar modules from competing brands near Philadelphia Solar PS-MNB156(HCBF)-620W (620.0 W), including Heliene 156HC-615 M10 NTYP SL Bifacial.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Heliene 156HC-615 M10 NTYP SL Bifacial**](https://epri-peac.com/solar-equipment/modules/heliene/heliene-156hc-615-m10-ntyp-sl-bifacial/) Heliene | 615.0 W | -5.0 W | 56.92 V | 22.04% | 94.9% |
| [**Elin Energy (Sirius PV) ELNSM78M-HC-BF-610**](https://epri-peac.com/solar-equipment/modules/elin-energy-sirius-pv/elin-energy-sirius-pv-elnsm78m-hc-bf-610/) Elin Energy (Sirius PV) | 610.0 W | -10.0 W | 54.63 V | 22.02% | 94.5% |
| [**JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD156N-R0-635**](https://epri-peac.com/solar-equipment/modules/jolywood-taizhou-solar-technology-co-ltd/jolywood-taizhou-solar-technology-co-ltd-jw-hd156n-r0-635/) JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD | 635.0 W | +15.0 W | 56.6 V | 22.68% | 94.6% |
| [**Boviet Solar Technology Co Ltd BVM7613M-605-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7613m-605-h-hc-bf/) Boviet Solar Technology Co Ltd | 605.0 W | -15.0 W | 54.4 V | 21.61% | 94.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Philadelphia Solar PS-MNB156(HCBF)-620W?

Evaluate Philadelphia Solar PS-MNB156(HCBF)-620W (620.0 W STC, 55.65 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Philadelphia Solar PS-MNB156(HCBF)-620W reaches 61.26 V per panel—exceeding 9 panels in series voids 600 V inverter warranties.
- Footprint constraint: 13 panels for an 8 kW build require 390 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Philadelphia Solar PS-MNB156(HCBF)-620W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Philadelphia Solar PS-MNB156(HCBF)-620W 8 kW Residential Fit

Needs 13 modules (390 sq ft) with a 25 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 9 panels (-10 C) or 9 panels (-20 C), or compare Heliene 156HC-615 M10 NTYP SL Bifacial.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 584.5 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Philadelphia Solar PS-MNB156(HCBF)-620W by Philadelphia Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Philadelphia Solar PS-MNB156(HCBF)-620W PTC wattage (584.5 W) lower than STC (620.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 584.5 W PTC (94.3% retention) across Philadelphia Solar PS-MNB156(HCBF)-620W's 2.79 m2 aperture.

### Who should skip Philadelphia Solar PS-MNB156(HCBF)-620W on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 13 Philadelphia Solar PS-MNB156(HCBF)-620W panels (390 sq ft) leave unusable roof gaps vs. Heliene 156HC-615 M10 NTYP SL Bifacial.

### What is the 1,000 V commercial string limit for Philadelphia Solar PS-MNB156(HCBF)-620W?

On 1,000 V commercial inverters at -10 C (60.01 V cold Voc), Philadelphia Solar PS-MNB156(HCBF)-620W fits up to 16 panels per series string.

## Related Pages

Compare Philadelphia Solar equipment, Heliene 156HC-615 M10 NTYP SL Bifacial specs, utility payback rates, and NEC string calculators alongside Philadelphia Solar PS-MNB156(HCBF)-620W.

[All Philadelphia Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/philadelphia-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Philadelphia Solar

- [All Philadelphia Solar Specs](https://epri-peac.com/solar-equipment/brands/philadelphia-solar/)
- [Philadelphia Solar PS-MNB156(HCBF)-650W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-mnb156-hcbf-650w/)
- [Philadelphia Solar PS-MNB156(HCBF)-635W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-mnb156-hcbf-635w/)
- [Philadelphia Solar PS-M156(HC)-605W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-m156-hc-605w/)
- [Philadelphia Solar PS-M156(HCBF)-GG-605W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-m156-hcbf-gg-605w/)
- [Philadelphia Solar PS-MNB144(HCBF)-605W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-mnb144-hcbf-605w/)