title: "Philadelphia Solar Specs (570.0W, 51.73V Voc)"
url: https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-mnb144-hcbf-570w/
description: "CEC datasheet for Philadelphia Solar PS-MNB144(HCBF)-570W: 570.0W STC, 51.73V Voc, 15-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Philadelphia Solar PS-MNB144(HCBF)-570W — CEC Solar Module Specifications

Manufacturer: [**Philadelphia Solar**](https://epri-peac.com/solar-equipment/brands/philadelphia-solar/) Registry: **CEC Verified Engineering Specification**

Philadelphia Solar PS-MNB144(HCBF)-570W is a 570.0 W STC (540.2 W PTC) Mono-c-Si solar module ranking #2,154 of 21,677 CEC listings (top 10.5%; higher than 89.5% of peers). It delivers 22.09% efficiency, 51.73 V Voc at 25 C, and 55.86 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 570.0 W

- **PTC Wattage** : 540.2 W

- **Voc @ 25C** : 51.73 V

- **Efficiency** : 22.09%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Philadelphia Solar PS-MNB144(HCBF)-570W Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Philadelphia Solar PS-MNB144(HCBF)-570W (Mono-c-Si) residential solar systems.

Philadelphia Solar PS-MNB144(HCBF)-570W delivers 220.9 W/m2 (2.18 percentage points above 19.91% CEC median) and strong 94.8% PTC-to-STC heat retention (#1,790 of 21,677), placing it as a large-format commercial and ground-mount module better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. At -4 F (-20 C), string voltage climbs to 57.04 V per unit, capping 600 V circuits at 10 panels. Compare specs directly with CSI Solar Co Ltd CS6W-570TB-AG (570.0 W).

## Where Does Philadelphia Solar PS-MNB144(HCBF)-570W Fall Across Listed CEC Models?

Comparison of Philadelphia Solar PS-MNB144(HCBF)-570W (570.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define Philadelphia Solar PS-MNB144(HCBF)-570W?

Relative ranking of Philadelphia Solar PS-MNB144(HCBF)-570W across nameplate watts, 94.8% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for Philadelphia Solar PS-MNB144(HCBF)-570W?

Summary of Philadelphia Solar PS-MNB144(HCBF)-570W output rank, 8 kW array size (15 panels), efficiency rating, and 600 V string limit.

Rank #2,154 / 21,677

### Top 10.5% STC Output

570.0 W STC (+185.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #2,842

### 22.09% Aperture Efficiency

Power density 220.9 W/m2 (2.18 percentage points above 19.91% CEC median). PTC/STC ratio: 94.8% (rank #1,790).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.86 V at -10 C (558.6 V string) and 57.04 V at -20 C (10 max).

 8 kW Reference Array

### 15 Panels = 8,550 W STC

Occupies 38.7 m2 (417 sq ft) producing 8,103 W PTC; NEC 690.8 OCPD floor is 21.87 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 51.73 * (1 + (-0.228/100) * (-10 - 25)) = 55.86 V | OCPD = 1.56 * 14.02 = 21.87 A

Inputs from CEC Modules.csv for Philadelphia Solar PS-MNB144(HCBF)-570W: Voc=51.73 V, beta_Voc=-0.228%/C, Isc=14.02 A, STC=570.0 W, Area=2.58 m2.

**Result:** 10 panels max on 600 V (558.6 V); 15 panels for 8 kW (417 sq ft).

## What Are the Published CEC Specifications for Philadelphia Solar PS-MNB144(HCBF)-570W?

Complete CEC test sheet for Philadelphia Solar PS-MNB144(HCBF)-570W including Isc (14.02 A), Voc (51.73 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Philadelphia Solar PS-MNB144(HCBF)-570W.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 570.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 540.2 W (94.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 51.73 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 14.02 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 43.15 V / 13.25 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.228 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 22.09% (2.58 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Philadelphia Solar PS-MNB144(HCBF)-570W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Philadelphia Solar PS-MNB144(HCBF)-570W.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 11 | 6.27 kW | 305 sq ft | $1,569 | $2,654 |
| **8 kW Class** | 15 | 8.55 kW | 417 sq ft | $2,140 | $3,619 |
| **10 kW Class** | 18 | 10.26 kW | 500 sq ft | $2,568 | $4,342 |

## How Many Philadelphia Solar PS-MNB144(HCBF)-570W Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Philadelphia Solar PS-MNB144(HCBF)-570W (51.73 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=51.73V and beta_Voc=-0.228%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 57.04 V | 10 panels | 570.4 V | 17 panels |
| **-10 C (14 F)** | 55.86 V | 10 panels | 558.6 V | 17 panels |
| **0 C (32 F)** | 54.68 V | 10 panels | 546.8 V | 18 panels |
| **25 C (77 F STC)** | 51.73 V | 11 panels | 569.0 V | 19 panels |

## Which Cross-Brand Solar Modules Compare Closest to Philadelphia Solar PS-MNB144(HCBF)-570W?

Four comparable CEC modules such as CSI Solar Co Ltd CS6W-570TB-AG (570.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS6W-570TB-AG**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6w-570tb-ag/) CSI Solar Co Ltd | 570.0 W | Tie (0 W) | 51.8 V | 22.71% | 94.9% |
| [**Gautam Solar Pvt Ltd G2G1710-HAD**](https://epri-peac.com/solar-equipment/modules/gautam-solar-pvt-ltd/gautam-solar-pvt-ltd-g2g1710-had/) Gautam Solar Pvt Ltd | 570.0 W | Tie (0 W) | 50.74 V | 22.2% | 95.1% |
| [**Gautam Solar Pvt Ltd G2X1710N-UHAD**](https://epri-peac.com/solar-equipment/modules/gautam-solar-pvt-ltd/gautam-solar-pvt-ltd-g2x1710n-uhad/) Gautam Solar Pvt Ltd | 570.0 W | Tie (0 W) | 50.74 V | 22.18% | 94.9% |
| [**EMMVEE Photovoltaic Power Private Limited E575HCBG144-T**](https://epri-peac.com/solar-equipment/modules/emmvee-photovoltaic-power-private-limited/emmvee-photovoltaic-power-private-limited-e575hcbg144-t/) EMMVEE Photovoltaic Power Private Limited | 575.0 W | +5.0 W | 51.27 V | 22.46% | 93.4% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Philadelphia Solar PS-MNB144(HCBF)-570W?

Evaluate Philadelphia Solar PS-MNB144(HCBF)-570W (570.0 W STC, 51.73 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Philadelphia Solar PS-MNB144(HCBF)-570W reaches 57.04 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Philadelphia Solar PS-MNB144(HCBF)-570W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Philadelphia Solar PS-MNB144(HCBF)-570W 8 kW Residential Fit

Needs 15 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,140/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare CSI Solar Co Ltd CS6W-570TB-AG.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 540.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Philadelphia Solar PS-MNB144(HCBF)-570W by Philadelphia Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Philadelphia Solar PS-MNB144(HCBF)-570W panels fit on a 600 V winter solar string?

At -10 C (14 F), Philadelphia Solar PS-MNB144(HCBF)-570W cold Voc rises from 51.73 V to 55.86 V (beta_Voc -0.228%/C), capping a 600 V string at 10 panels (558.6 V).

### How much roof area does an 8 kW array of Philadelphia Solar PS-MNB144(HCBF)-570W need?

An 8 kW DC system uses 15 Philadelphia Solar PS-MNB144(HCBF)-570W modules (8,550 W STC / 8,103 W PTC), covering roughly 417 sq ft and saving ~$2,140/yr at 18.54 c/kWh.

### How does Philadelphia Solar PS-MNB144(HCBF)-570W compare against CSI Solar Co Ltd CS6W-570TB-AG?

Philadelphia Solar PS-MNB144(HCBF)-570W outputs 570.0 W STC (51.73 V Voc, rank #2,154 of 21,677), while CSI Solar Co Ltd CS6W-570TB-AG delivers 570.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Philadelphia Solar equipment, CSI Solar Co Ltd CS6W-570TB-AG specs, utility payback rates, and NEC string calculators alongside Philadelphia Solar PS-MNB144(HCBF)-570W.

[All Philadelphia Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/philadelphia-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Philadelphia Solar

- [All Philadelphia Solar Specs](https://epri-peac.com/solar-equipment/brands/philadelphia-solar/)
- [Philadelphia Solar PS-MNB156(HCBF)-650W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-mnb156-hcbf-650w/)
- [Philadelphia Solar PS-MNB156(HCBF)-635W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-mnb156-hcbf-635w/)
- [Philadelphia Solar PS-MNB156(HCBF)-620W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-mnb156-hcbf-620w/)
- [Philadelphia Solar PS-M156(HC)-605W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-m156-hc-605w/)
- [Philadelphia Solar PS-M156(HCBF)-GG-605W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-m156-hcbf-gg-605w/)