# Philadelphia Solar PS-M72(BF)-405 — CEC Solar Module Specifications

Manufacturer: [**Philadelphia Solar**](https://epri-peac.com/solar-equipment/brands/philadelphia-solar/) Registry: **CEC Verified Engineering Specification**

Philadelphia Solar PS-M72(BF)-405 is a 405.0 W STC (377.8 W PTC) Mono-c-Si solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 20.25% efficiency, 50.8 V Voc at 25 C, and 55.55 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 405.0 W

- **PTC Wattage** : 377.8 W

- **Voc @ 25C** : 50.8 V

- **Efficiency** : 20.25%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Philadelphia Solar PS-M72(BF)-405 Compare Against Peer CEC Listings?

How Philadelphia Solar Philadelphia Solar PS-M72(BF)-405 handles rooftop heat (377.8 W PTC), 8 kW sizing, and cold winter string voltage.

Philadelphia Solar builds the Philadelphia Solar PS-M72(BF)-405 (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 202.5 W/m2 (0.34 percentage points above 19.91% CEC median). Compared against Boviet Solar Technology Co Ltd BVM6612M-405L-H-BF (405.0 W), this model holds strong 93.3% PTC-to-STC heat retention (#8,323 of 21,677). Higher 50.8 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), while NEC 690.8 sets a 15.72 A overcurrent floor served by a 20 A breaker.

## Where Does Philadelphia Solar PS-M72(BF)-405 Fall Across Listed CEC Models?

Where Philadelphia Solar PS-M72(BF)-405 (405.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Philadelphia Solar PS-M72(BF)-405?

Percentile placement of Philadelphia Solar PS-M72(BF)-405 across power density (202.5 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Philadelphia Solar PS-M72(BF)-405?

Four critical engineering numbers homeowners and solar installers check first when reviewing Philadelphia Solar PS-M72(BF)-405 specifications.

Rank #8,961 / 21,677

### Top 43.4% STC Output

405.0 W STC (+20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,573

### 20.25% Aperture Efficiency

Power density 202.5 W/m2 (0.34 percentage points above 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.55 V at -10 C (555.5 V string) and 56.9 V at -20 C (10 max).

 8 kW Reference Array

### 20 Panels = 8,100 W STC

Occupies 40.0 m2 (431 sq ft) producing 7,556 W PTC; NEC 690.8 OCPD floor is 15.72 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 50.8 * (1 + (-0.267/100) * (-10 - 25)) = 55.55 V | OCPD = 1.56 * 10.08 = 15.72 A

Inputs from CEC Modules.csv for Philadelphia Solar PS-M72(BF)-405: Voc=50.8 V, beta_Voc=-0.267%/C, Isc=10.08 A, STC=405.0 W, Area=2.0 m2.

**Result:** 10 panels max on 600 V (555.5 V); 20 panels for 8 kW (431 sq ft).

## What Are the Published CEC Specifications for Philadelphia Solar PS-M72(BF)-405?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Philadelphia Solar PS-M72(BF)-405.

Official California Energy Commission (NREL SAM) test parameters for Philadelphia Solar PS-M72(BF)-405.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 405.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 377.8 W (93.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 50.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 10.08 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 42.1 V / 9.62 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.267 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.25% (2.0 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Philadelphia Solar PS-M72(BF)-405 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Philadelphia Solar PS-M72(BF)-405 (405.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 15 | 6.08 kW | 323 sq ft | $1,522 | $2,573 |
| **8 kW Class** | 20 | 8.1 kW | 431 sq ft | $2,027 | $3,428 |
| **10 kW Class** | 25 | 10.12 kW | 538 sq ft | $2,533 | $4,283 |

## Which Sibling Wattage & Trim Variants Belong to This Philadelphia Solar Series?

All closely matched Philadelphia Solar wattages and cosmetic trims sharing the Philadelphia Solar PS-M72(BF)-405 architecture. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sibling CEC listings grouped into the Philadelphia Solar PS-M72(BF)-405 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Philadelphia Solar PS-M72(BF)-400** | 400.0 W | 373.0 W | 50.52 V | 41.8 V | 20.0% |
| **Philadelphia Solar PS-M72(BF)-405** | 405.0 W | 377.8 W | 50.8 V | 42.1 V | 20.25% |

## How Many Philadelphia Solar PS-M72(BF)-405 Modules Fit in a Cold-Weather String?

Maximum series module counts for Philadelphia Solar PS-M72(BF)-405 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=50.8V and beta_Voc=-0.267%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 56.9 V | 10 panels | 569.0 V | 17 panels |
| **-10 C (14 F)** | 55.55 V | 10 panels | 555.5 V | 18 panels |
| **0 C (32 F)** | 54.19 V | 11 panels | 596.1 V | 18 panels |
| **25 C (77 F STC)** | 50.8 V | 11 panels | 558.8 V | 19 panels |

## Which Cross-Brand Solar Modules Compare Closest to Philadelphia Solar PS-M72(BF)-405?

Alternative CEC solar modules from competing brands near Philadelphia Solar PS-M72(BF)-405 (405.0 W), including Boviet Solar Technology Co Ltd BVM6612M-405L-H-BF.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Boviet Solar Technology Co Ltd BVM6612M-405L-H-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-405l-h-bf/) Boviet Solar Technology Co Ltd | 405.0 W | Tie (0 W) | 49.45 V | 20.15% | 93.4% |
| [**Boviet Solar Technology Co Ltd BVM6612M-405L-H-BF-DG**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-405l-h-bf-dg/) Boviet Solar Technology Co Ltd | 405.0 W | Tie (0 W) | 49.45 V | 20.05% | 93.7% |
| [**Boviet Solar Technology Co Ltd BVM6612M-405L-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-405l-h-hc-bf/) Boviet Solar Technology Co Ltd | 405.0 W | Tie (0 W) | 49.45 V | 19.76% | 93.7% |
| [**Boviet Solar Technology Co Ltd BVM6612M-405L-H-HC-BF-DG**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-405l-h-hc-bf-dg/) Boviet Solar Technology Co Ltd | 405.0 W | Tie (0 W) | 49.45 V | 19.76% | 93.8% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Philadelphia Solar PS-M72(BF)-405?

Evaluate Philadelphia Solar PS-M72(BF)-405 (405.0 W STC, 50.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Philadelphia Solar PS-M72(BF)-405 reaches 56.9 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 431 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (431 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Philadelphia Solar PS-M72(BF)-405 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Philadelphia Solar PS-M72(BF)-405 8 kW Residential Fit

Needs 20 modules (431 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-405L-H-BF.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 377.8 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Philadelphia Solar PS-M72(BF)-405 by Philadelphia Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Philadelphia Solar PS-M72(BF)-405?

Multiplying Philadelphia Solar PS-M72(BF)-405's 10.08 A short-circuit current by 1.56 equals 15.72 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

### Can Philadelphia Solar PS-M72(BF)-405 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 55.55 V cold Voc at 14 F and handles 10.08 A Isc; string inverters cap Philadelphia Solar PS-M72(BF)-405 at 10 panels on 600 V.

### Is Philadelphia Solar PS-M72(BF)-405 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Philadelphia Solar PS-M72(BF)-405 rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

## Related Pages

Compare Philadelphia Solar equipment, Boviet Solar Technology Co Ltd BVM6612M-405L-H-BF specs, utility payback rates, and NEC string calculators alongside Philadelphia Solar PS-M72(BF)-405.

[All Philadelphia Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/philadelphia-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Philadelphia Solar

- [All Philadelphia Solar Specs](https://epri-peac.com/solar-equipment/brands/philadelphia-solar/)
- [Philadelphia Solar PS-MNB156(HCBF)-650W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-mnb156-hcbf-650w/)
- [Philadelphia Solar PS-MNB156(HCBF)-635W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-mnb156-hcbf-635w/)
- [Philadelphia Solar PS-MNB156(HCBF)-620W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-mnb156-hcbf-620w/)
- [Philadelphia Solar PS-M156(HC)-605W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-m156-hc-605w/)
- [Philadelphia Solar PS-M156(HCBF)-GG-605W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-m156-hcbf-gg-605w/)