# Philadelphia Solar PS-M72-385 — CEC Solar Module Specifications

Manufacturer: [**Philadelphia Solar**](https://epri-peac.com/solar-equipment/brands/philadelphia-solar/) Registry: **CEC Verified Engineering Specification**

Philadelphia Solar PS-M72-385 is a 385.0 W STC (352.4 W PTC) Mono-c-Si solar module ranking #10,723 of 21,677 CEC listings (at all-CEC median; higher than 49.1% of peers). It delivers 19.25% efficiency, 49.04 V Voc at 25 C, and 54.24 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 385.0 W

- **PTC Wattage** : 352.4 W

- **Voc @ 25C** : 49.04 V

- **Efficiency** : 19.25%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Philadelphia Solar PS-M72-385 Compare Against Peer CEC Listings?

Solar engineering breakdown for Philadelphia Solar PS-M72-385: PTC thermal retention, roof footprint, and cold Voc string bounds. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Measured at 385.0 W STC and 352.4 W PTC, Philadelphia Solar PS-M72-385 sits equal to all-CEC median (at all-CEC median; higher than 49.1% of peers) among 21,677 listed modules. Power density reaches 192.5 W/m2 (0.66 percentage points below 19.91% CEC median). Higher 49.04 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 18 panels in series. Alternative peer EMMVEE Photovoltaic Power Private Limited E385M72 rates 385.0 W.

## Where Does Philadelphia Solar PS-M72-385 Fall Across Listed CEC Models?

Distribution marker showing Philadelphia Solar PS-M72-385 (385.0 W) relative to the 385.0 W all-CEC solar panel median. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

## What Dataset Percentiles Define Philadelphia Solar PS-M72-385?

Dataset percentiles tracking Philadelphia Solar PS-M72-385 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

## What Do the Dataset Ranks Show for Philadelphia Solar PS-M72-385?

Benchmark highlights for Philadelphia Solar PS-M72-385 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Rank #10,723 / 21,677

### 385.0 W STC · Higher Than 49.1%

385.0 W STC (equal to all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #12,863

### 19.25% Aperture Efficiency

Power density 192.5 W/m2 (0.66 percentage points below 19.91% CEC median). PTC/STC ratio: 91.5% (rank #15,584).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.24 V at -10 C (596.6 V string) and 55.73 V at -20 C (10 max).

 8 kW Reference Array

### 21 Panels = 8,085 W STC

Occupies 42.0 m2 (452 sq ft) producing 7,400 W PTC; NEC 690.8 OCPD floor is 15.49 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.04 * (1 + (-0.303/100) * (-10 - 25)) = 54.24 V | OCPD = 1.56 * 9.93 = 15.49 A

Inputs from CEC Modules.csv for Philadelphia Solar PS-M72-385: Voc=49.04 V, beta_Voc=-0.303%/C, Isc=9.93 A, STC=385.0 W, Area=2.0 m2.

**Result:** 11 panels max on 600 V (596.6 V); 21 panels for 8 kW (452 sq ft).

## What Are the Published CEC Specifications for Philadelphia Solar PS-M72-385?

Official CEC datasheet figures for Philadelphia Solar PS-M72-385 (Mono-c-Si) used in utility interconnection and permit reviews. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Official California Energy Commission (NREL SAM) test parameters for Philadelphia Solar PS-M72-385.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 385.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 352.4 W (91.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 49.04 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.93 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 40.96 V / 9.4 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.303 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 19.25% (2.0 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Philadelphia Solar PS-M72-385 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Philadelphia Solar PS-M72-385 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 16 | 6.16 kW | 344 sq ft | $1,542 | $2,607 |
| **8 kW Class** | 21 | 8.09 kW | 452 sq ft | $2,025 | $3,424 |
| **10 kW Class** | 26 | 10.01 kW | 560 sq ft | $2,505 | $4,236 |

## Which Sibling Wattage & Trim Variants Belong to This Philadelphia Solar Series?

Consolidated Philadelphia Solar wattage variants sharing the Philadelphia Solar PS-M72-385 mechanical and cell layout. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the Philadelphia Solar PS-M72-385 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Philadelphia Solar PS-M72-375** | 375.0 W | 343.0 W | 48.44 V | 40.39 V | 18.75% |
| **Philadelphia Solar PS-M72-380** | 380.0 W | 347.7 W | 48.74 V | 40.7 V | 19.0% |
| **Philadelphia Solar PS-M72-385** | 385.0 W | 352.4 W | 49.04 V | 40.96 V | 19.25% |
| **Philadelphia Solar PS-M72-390** | 390.0 W | 357.2 W | 49.34 V | 41.27 V | 19.5% |
| **Philadelphia Solar PS-M72-395** | 395.0 W | 361.9 W | 49.64 V | 41.57 V | 19.75% |

## How Many Philadelphia Solar PS-M72-385 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Philadelphia Solar PS-M72-385 (54.24 V at 14 F).

Computed from Voc=49.04V and beta_Voc=-0.303%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 55.73 V | 10 panels | 557.3 V | 17 panels |
| **-10 C (14 F)** | 54.24 V | 11 panels | 596.6 V | 18 panels |
| **0 C (32 F)** | 52.75 V | 11 panels | 580.2 V | 18 panels |
| **25 C (77 F STC)** | 49.04 V | 12 panels | 588.5 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to Philadelphia Solar PS-M72-385?

Competing CEC solar panels closest to Philadelphia Solar PS-M72-385 in nameplate wattage and Voc, starting with EMMVEE Photovoltaic Power Private Limited E385M72.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**EMMVEE Photovoltaic Power Private Limited E385M72**](https://epri-peac.com/solar-equipment/modules/emmvee-photovoltaic-power-private-limited/emmvee-photovoltaic-power-private-limited-e385m72/) EMMVEE Photovoltaic Power Private Limited | 385.0 W | Tie (0 W) | 48.9 V | 19.32% | 92.0% |
| [**Boviet Solar Technology Co Ltd BVM6612M-385-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-385-h/) Boviet Solar Technology Co Ltd | 385.0 W | Tie (0 W) | 48.5 V | 19.85% | 93.1% |
| [**Boviet Solar Technology Co Ltd BVM6612M-W5-385-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-w5-385-h/) Boviet Solar Technology Co Ltd | 385.0 W | Tie (0 W) | 48.5 V | 19.85% | 93.1% |
| [**Boviet Solar Technology Co Ltd BVM6612M-385L-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-385l-h/) Boviet Solar Technology Co Ltd | 385.0 W | Tie (0 W) | 48.45 V | 19.35% | 93.2% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Philadelphia Solar PS-M72-385?

Evaluate Philadelphia Solar PS-M72-385 (385.0 W STC, 49.04 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Philadelphia Solar PS-M72-385 reaches 55.73 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 452 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 21 panels (452 sq ft).
- 2026 tax credit baseline: cash residential installs of Philadelphia Solar PS-M72-385 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Philadelphia Solar PS-M72-385 8 kW Residential Fit

Needs 21 modules (452 sq ft) with a 20 A string OCPD, offsetting ~$2,025/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare EMMVEE Photovoltaic Power Private Limited E385M72.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 352.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Philadelphia Solar PS-M72-385 by Philadelphia Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Philadelphia Solar PS-M72-385 panels fit on a 600 V winter solar string?

At -10 C (14 F), Philadelphia Solar PS-M72-385 cold Voc rises from 49.04 V to 54.24 V (beta_Voc -0.303%/C), capping a 600 V string at 11 panels (596.6 V).

### How much roof area does an 8 kW array of Philadelphia Solar PS-M72-385 need?

An 8 kW DC system uses 21 Philadelphia Solar PS-M72-385 modules (8,085 W STC / 7,400 W PTC), covering roughly 452 sq ft and saving ~$2,025/yr at 18.54 c/kWh.

### How does Philadelphia Solar PS-M72-385 compare against EMMVEE Photovoltaic Power Private Limited E385M72?

Philadelphia Solar PS-M72-385 outputs 385.0 W STC (49.04 V Voc, rank #10,723 of 21,677), while EMMVEE Photovoltaic Power Private Limited E385M72 delivers 385.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Philadelphia Solar equipment, EMMVEE Photovoltaic Power Private Limited E385M72 specs, utility payback rates, and NEC string calculators alongside Philadelphia Solar PS-M72-385.

[All Philadelphia Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/philadelphia-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Philadelphia Solar

- [All Philadelphia Solar Specs](https://epri-peac.com/solar-equipment/brands/philadelphia-solar/)
- [Philadelphia Solar PS-MNB156(HCBF)-650W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-mnb156-hcbf-650w/)
- [Philadelphia Solar PS-MNB156(HCBF)-635W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-mnb156-hcbf-635w/)
- [Philadelphia Solar PS-MNB156(HCBF)-620W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-mnb156-hcbf-620w/)
- [Philadelphia Solar PS-M156(HC)-605W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-m156-hc-605w/)
- [Philadelphia Solar PS-M156(HCBF)-GG-605W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-m156-hcbf-gg-605w/)