title: "Philadelphia Solar PS-M60(BF)-295 Specs (295.0W, 39.6V Voc)"
url: https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-m60-bf-295/
description: "CEC datasheet for Philadelphia Solar PS-M60(BF)-295: 295.0W STC, 39.6V Voc, 28-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Philadelphia Solar PS-M60(BF)-295 — CEC Solar Module Specifications

Manufacturer: [**Philadelphia Solar**](https://epri-peac.com/solar-equipment/brands/philadelphia-solar/) Registry: **CEC Verified Engineering Specification**

Philadelphia Solar PS-M60(BF)-295 is a 295.0 W STC (270.7 W PTC) Mono-c-Si solar module ranking #16,890 of 21,677 CEC listings (below all-CEC median; higher than 20.4% of peers). It delivers 18.21% efficiency, 39.6 V Voc at 25 C, and 43.34 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 295.0 W

- **PTC Wattage** : 270.7 W

- **Voc @ 25C** : 39.6 V

- **Efficiency** : 18.21%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Philadelphia Solar PS-M60(BF)-295 Compare Against Peer CEC Listings?

How Philadelphia Solar Philadelphia Solar PS-M60(BF)-295 handles rooftop heat (270.7 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Philadelphia Solar PS-M60(BF)-295 exhibits 9.83 A short-circuit current, requiring a 15.33 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #16,890 of 21,677 (115.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 45.4 m2 for an 8 kW system (34 panels for 10 kW). Lower 39.6 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters.

## Where Does Philadelphia Solar PS-M60(BF)-295 Fall Across Listed CEC Models?

Where Philadelphia Solar PS-M60(BF)-295 (295.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Philadelphia Solar PS-M60(BF)-295?

Percentile placement of Philadelphia Solar PS-M60(BF)-295 across power density (182.1 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Philadelphia Solar PS-M60(BF)-295?

Four critical engineering numbers homeowners and solar installers check first when reviewing Philadelphia Solar PS-M60(BF)-295 specifications.

Rank #16,890 / 21,677

### 295.0 W STC · Higher Than 20.4%

295.0 W STC (-90.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #14,805

### 18.21% Aperture Efficiency

Power density 182.1 W/m2 (1.70 percentage points below 19.91% CEC median). PTC/STC ratio: 91.8% (rank #14,745).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.34 V at -10 C (563.4 V string) and 44.41 V at -20 C (13 max).

 8 kW Reference Array

### 28 Panels = 8,260 W STC

Occupies 45.4 m2 (488 sq ft) producing 7,580 W PTC; NEC 690.8 OCPD floor is 15.33 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.6 * (1 + (-0.27/100) * (-10 - 25)) = 43.34 V | OCPD = 1.56 * 9.83 = 15.33 A

Inputs from CEC Modules.csv for Philadelphia Solar PS-M60(BF)-295: Voc=39.6 V, beta_Voc=-0.27%/C, Isc=9.83 A, STC=295.0 W, Area=1.62 m2.

**Result:** 13 panels max on 600 V (563.4 V); 28 panels for 8 kW (488 sq ft).

## What Are the Published CEC Specifications for Philadelphia Solar PS-M60(BF)-295?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Philadelphia Solar PS-M60(BF)-295.

Official California Energy Commission (NREL SAM) test parameters for Philadelphia Solar PS-M60(BF)-295.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 295.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 270.7 W (91.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 39.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.83 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 31.74 V / 9.3 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.27 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 18.21% (1.62 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Philadelphia Solar PS-M60(BF)-295 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Philadelphia Solar PS-M60(BF)-295 (295.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 21 | 6.2 kW | 366 sq ft | $1,552 | $2,624 |
| **8 kW Class** | 28 | 8.26 kW | 488 sq ft | $2,067 | $3,496 |
| **10 kW Class** | 34 | 10.03 kW | 593 sq ft | $2,510 | $4,245 |

## How Many Philadelphia Solar PS-M60(BF)-295 Modules Fit in a Cold-Weather String?

Maximum series module counts for Philadelphia Solar PS-M60(BF)-295 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=39.6V and beta_Voc=-0.27%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 44.41 V | 13 panels | 577.3 V | 22 panels |
| **-10 C (14 F)** | 43.34 V | 13 panels | 563.4 V | 23 panels |
| **0 C (32 F)** | 42.27 V | 14 panels | 591.8 V | 23 panels |
| **25 C (77 F STC)** | 39.6 V | 15 panels | 594.0 V | 25 panels |

## Which Cross-Brand Solar Modules Compare Closest to Philadelphia Solar PS-M60(BF)-295?

Alternative CEC solar modules from competing brands near Philadelphia Solar PS-M60(BF)-295 (295.0 W), including Auxin Solar AXN6M610B295.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Auxin Solar AXN6M610B295**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn6m610b295/) Auxin Solar | 295.0 W | Tie (0 W) | 40.11 V | 17.85% | 92.9% |
| [**GCL System Integration Technology Co Ltd GCL-M6/60295**](https://epri-peac.com/solar-equipment/modules/gcl-system-integration-technology-co-ltd/gcl-system-integration-technology-co-ltd-gcl-m6-60295/) GCL System Integration Technology Co Ltd | 295.0 W | Tie (0 W) | 39.3 V | 18.1% | 90.2% |
| [**CSI Solar Co Ltd CS3K-295MS**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3k-295ms/) CSI Solar Co Ltd | 295.0 W | Tie (0 W) | 39.1 V | 18.4% | 93.0% |
| [**DualSun SAS DualSun 290M-60-00**](https://epri-peac.com/solar-equipment/modules/dualsun-sas/dualsun-sas-dualsun-290m-60-00/) DualSun SAS | 290.0 W | -5.0 W | 39.7 V | 17.68% | 90.9% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Philadelphia Solar PS-M60(BF)-295?

Evaluate Philadelphia Solar PS-M60(BF)-295 (295.0 W STC, 39.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Philadelphia Solar PS-M60(BF)-295 reaches 44.41 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 28 panels for an 8 kW build require 488 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (488 sq ft).
- 2026 tax credit baseline: cash residential installs of Philadelphia Solar PS-M60(BF)-295 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Philadelphia Solar PS-M60(BF)-295 8 kW Residential Fit

Needs 28 modules (488 sq ft) with a 20 A string OCPD, offsetting ~$2,067/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Auxin Solar AXN6M610B295.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 270.7 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Philadelphia Solar PS-M60(BF)-295 by Philadelphia Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Philadelphia Solar PS-M60(BF)-295 PTC wattage (270.7 W) lower than STC (295.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 270.7 W PTC (91.8% retention) across Philadelphia Solar PS-M60(BF)-295's 1.62 m2 aperture.

### Who should skip Philadelphia Solar PS-M60(BF)-295 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 28 Philadelphia Solar PS-M60(BF)-295 panels (488 sq ft) leave unusable roof gaps vs. Auxin Solar AXN6M610B295.

### What is the 1,000 V commercial string limit for Philadelphia Solar PS-M60(BF)-295?

On 1,000 V commercial inverters at -10 C (43.34 V cold Voc), Philadelphia Solar PS-M60(BF)-295 fits up to 23 panels per series string.

## Related Pages

Compare Philadelphia Solar equipment, Auxin Solar AXN6M610B295 specs, utility payback rates, and NEC string calculators alongside Philadelphia Solar PS-M60(BF)-295.

[All Philadelphia Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/philadelphia-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Philadelphia Solar

- [All Philadelphia Solar Specs](https://epri-peac.com/solar-equipment/brands/philadelphia-solar/)
- [Philadelphia Solar PS-MNB156(HCBF)-650W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-mnb156-hcbf-650w/)
- [Philadelphia Solar PS-MNB156(HCBF)-635W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-mnb156-hcbf-635w/)
- [Philadelphia Solar PS-MNB156(HCBF)-620W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-mnb156-hcbf-620w/)
- [Philadelphia Solar PS-M156(HC)-605W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-m156-hc-605w/)
- [Philadelphia Solar PS-M156(HCBF)-GG-605W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-m156-hcbf-gg-605w/)