title: "Philadelphia Solar Specs (600.0W, 55.1V Voc)"
url: https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-m156-hcbf-600w/
description: "CEC datasheet for Philadelphia Solar PS-M156(HCBF)-600W: 600.0W STC, 55.1V Voc, 14-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Philadelphia Solar PS-M156(HCBF)-600W — CEC Solar Module Specifications

Manufacturer: [**Philadelphia Solar**](https://epri-peac.com/solar-equipment/brands/philadelphia-solar/) Registry: **CEC Verified Engineering Specification**

Philadelphia Solar PS-M156(HCBF)-600W is a 600.0 W STC (562.8 W PTC) Mono-c-Si solar module ranking #1,320 of 21,677 CEC listings (top 6.7%; higher than 93.3% of peers). It delivers 21.66% efficiency, 55.1 V Voc at 25 C, and 60.06 V cold Voc at -10 C (9 panels max per 600 V string).

- **STC Wattage** : 600.0 W

- **PTC Wattage** : 562.8 W

- **Voc @ 25C** : 55.1 V

- **Efficiency** : 21.66%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Philadelphia Solar PS-M156(HCBF)-600W Compare Against Peer CEC Listings?

Solar engineering breakdown for Philadelphia Solar PS-M156(HCBF)-600W: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 600.0 W STC and 562.8 W PTC, Philadelphia Solar PS-M156(HCBF)-600W sits +215.0 W vs all-CEC median (top 6.7%; higher than 93.3% of peers) among 21,677 listed modules. Power density reaches 216.6 W/m2 (1.75 percentage points above 19.91% CEC median). Higher 55.1 V open-circuit voltage caps 600 V residential strings at 9 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 16 panels in series. Alternative peer JA Solar JAM72D40-600/MB-US rates 600.0 W.

## Where Does Philadelphia Solar PS-M156(HCBF)-600W Fall Across Listed CEC Models?

Distribution marker showing Philadelphia Solar PS-M156(HCBF)-600W (600.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define Philadelphia Solar PS-M156(HCBF)-600W?

Dataset percentiles tracking Philadelphia Solar PS-M156(HCBF)-600W power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for Philadelphia Solar PS-M156(HCBF)-600W?

Benchmark highlights for Philadelphia Solar PS-M156(HCBF)-600W covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #1,320 / 21,677

### Top 6.7% STC Output

600.0 W STC (+215.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,983

### 21.66% Aperture Efficiency

Power density 216.6 W/m2 (1.75 percentage points above 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).

NEC 690.7 Limit

### 9 Panels Max @ -10 C (600 V)

Cold Voc reaches 60.06 V at -10 C (540.5 V string) and 61.47 V at -20 C (9 max).

 8 kW Reference Array

### 14 Panels = 8,400 W STC

Occupies 38.8 m2 (417 sq ft) producing 7,879 W PTC; NEC 690.8 OCPD floor is 21.62 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 55.1 * (1 + (-0.257/100) * (-10 - 25)) = 60.06 V | OCPD = 1.56 * 13.86 = 21.62 A

Inputs from CEC Modules.csv for Philadelphia Solar PS-M156(HCBF)-600W: Voc=55.1 V, beta_Voc=-0.257%/C, Isc=13.86 A, STC=600.0 W, Area=2.77 m2.

**Result:** 9 panels max on 600 V (540.5 V); 14 panels for 8 kW (417 sq ft).

## What Are the Published CEC Specifications for Philadelphia Solar PS-M156(HCBF)-600W?

Official CEC datasheet figures for Philadelphia Solar PS-M156(HCBF)-600W (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Philadelphia Solar PS-M156(HCBF)-600W.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 600.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 562.8 W (93.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 55.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.86 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 46.26 V / 12.99 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.257 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.66% (2.77 m2) | Array roof footprint density |
| **Cell Count & Technology** | 78 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Philadelphia Solar PS-M156(HCBF)-600W Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Philadelphia Solar PS-M156(HCBF)-600W modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 10 | 6.0 kW | 298 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 14 | 8.4 kW | 417 sq ft | $2,102 | $3,555 |
| **10 kW Class** | 17 | 10.2 kW | 507 sq ft | $2,553 | $4,317 |

## How Many Philadelphia Solar PS-M156(HCBF)-600W Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Philadelphia Solar PS-M156(HCBF)-600W (60.06 V at 14 F).

Computed from Voc=55.1V and beta_Voc=-0.257%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 61.47 V | 9 panels | 553.2 V | 16 panels |
| **-10 C (14 F)** | 60.06 V | 9 panels | 540.5 V | 16 panels |
| **0 C (32 F)** | 58.64 V | 10 panels | 586.4 V | 17 panels |
| **25 C (77 F STC)** | 55.1 V | 10 panels | 551.0 V | 18 panels |

## Which Cross-Brand Solar Modules Compare Closest to Philadelphia Solar PS-M156(HCBF)-600W?

Competing CEC solar panels closest to Philadelphia Solar PS-M156(HCBF)-600W in nameplate wattage and Voc, starting with JA Solar JAM72D40-600/MB-US.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**JA Solar JAM72D40-600/MB-US**](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb-us/) JA Solar | 600.0 W | Tie (0 W) | 54.3 V | 23.81% | 95.1% |
| [**HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S600OJ**](https://epri-peac.com/solar-equipment/modules/hd-hyundai-energy-solutions-co-ltd/hd-hyundai-energy-solutions-co-ltd-his-s600oj/) HD HYUNDAI ENERGY SOLUTIONS CO LTD | 600.0 W | Tie (0 W) | 54.2 V | 21.74% | 93.3% |
| [**FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-600**](https://epri-peac.com/solar-equipment/modules/fs-green-energies-private-limited/fs-green-energies-private-limited-fst-m10144g-600/) FS GREEN ENERGIES PRIVATE LIMITED | 600.0 W | Tie (0 W) | 53.7 V | 23.44% | 95.1% |
| [**AMPS Solar AMPS-600N-144SW**](https://epri-peac.com/solar-equipment/modules/amps-solar/amps-solar-amps-600n-144sw/) AMPS Solar | 600.0 W | Tie (0 W) | 53.3 V | 23.44% | 95.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Philadelphia Solar PS-M156(HCBF)-600W?

Evaluate Philadelphia Solar PS-M156(HCBF)-600W (600.0 W STC, 55.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Philadelphia Solar PS-M156(HCBF)-600W reaches 61.47 V per panel—exceeding 9 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Philadelphia Solar PS-M156(HCBF)-600W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Philadelphia Solar PS-M156(HCBF)-600W 8 kW Residential Fit

Needs 14 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 9 panels (-10 C) or 9 panels (-20 C), or compare JA Solar JAM72D40-600/MB-US.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 562.8 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Philadelphia Solar PS-M156(HCBF)-600W by Philadelphia Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Philadelphia Solar PS-M156(HCBF)-600W panels fit on a 600 V winter solar string?

At -10 C (14 F), Philadelphia Solar PS-M156(HCBF)-600W cold Voc rises from 55.1 V to 60.06 V (beta_Voc -0.257%/C), capping a 600 V string at 9 panels (540.5 V).

### How much roof area does an 8 kW array of Philadelphia Solar PS-M156(HCBF)-600W need?

An 8 kW DC system uses 14 Philadelphia Solar PS-M156(HCBF)-600W modules (8,400 W STC / 7,879 W PTC), covering roughly 417 sq ft and saving ~$2,102/yr at 18.54 c/kWh.

### How does Philadelphia Solar PS-M156(HCBF)-600W compare against JA Solar JAM72D40-600/MB-US?

Philadelphia Solar PS-M156(HCBF)-600W outputs 600.0 W STC (55.1 V Voc, rank #1,320 of 21,677), while JA Solar JAM72D40-600/MB-US delivers 600.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Philadelphia Solar equipment, JA Solar JAM72D40-600/MB-US specs, utility payback rates, and NEC string calculators alongside Philadelphia Solar PS-M156(HCBF)-600W.

[All Philadelphia Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/philadelphia-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Philadelphia Solar

- [All Philadelphia Solar Specs](https://epri-peac.com/solar-equipment/brands/philadelphia-solar/)
- [Philadelphia Solar PS-MNB156(HCBF)-650W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-mnb156-hcbf-650w/)
- [Philadelphia Solar PS-MNB156(HCBF)-635W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-mnb156-hcbf-635w/)
- [Philadelphia Solar PS-MNB156(HCBF)-620W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-mnb156-hcbf-620w/)
- [Philadelphia Solar PS-M156(HC)-605W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-m156-hc-605w/)
- [Philadelphia Solar PS-M156(HCBF)-GG-605W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-m156-hcbf-gg-605w/)