# Philadelphia Solar PS-M156(HCBF)-585W — CEC Solar Module Specifications

Manufacturer: [**Philadelphia Solar**](https://epri-peac.com/solar-equipment/brands/philadelphia-solar/) Registry: **CEC Verified Engineering Specification**

Philadelphia Solar PS-M156(HCBF)-585W is a 585.0 W STC (548.3 W PTC) Mono-c-Si solar module ranking #1,751 of 21,677 CEC listings (top 8.7%; higher than 91.3% of peers). It delivers 21.12% efficiency, 54.35 V Voc at 25 C, and 59.24 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 585.0 W

- **PTC Wattage** : 548.3 W

- **Voc @ 25C** : 54.35 V

- **Efficiency** : 21.12%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Philadelphia Solar PS-M156(HCBF)-585W Compare Against Peer CEC Listings?

Solar engineering breakdown for Philadelphia Solar PS-M156(HCBF)-585W: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from Philadelphia Solar and peers, Philadelphia Solar PS-M156(HCBF)-585W stands 175.0 W above the 410.0 W Mono-c-Si median and strong 93.7% PTC-to-STC heat retention (#6,162 of 21,677). Sizing 6 kW (11 panels) to 10 kW (18 panels) yields $1,609-$2,636/yr in baseline US bill offset. Higher 54.35 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

## Where Does Philadelphia Solar PS-M156(HCBF)-585W Fall Across Listed CEC Models?

Distribution marker showing Philadelphia Solar PS-M156(HCBF)-585W (585.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define Philadelphia Solar PS-M156(HCBF)-585W?

Dataset percentiles tracking Philadelphia Solar PS-M156(HCBF)-585W power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for Philadelphia Solar PS-M156(HCBF)-585W?

Benchmark highlights for Philadelphia Solar PS-M156(HCBF)-585W covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #1,751 / 21,677

### Top 8.7% STC Output

585.0 W STC (+200.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,831

### 21.12% Aperture Efficiency

Power density 211.2 W/m2 (1.21 percentage points above 19.91% CEC median). PTC/STC ratio: 93.7% (rank #6,162).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 59.24 V at -10 C (592.4 V string) and 60.64 V at -20 C (9 max).

 8 kW Reference Array

### 14 Panels = 8,190 W STC

Occupies 38.8 m2 (417 sq ft) producing 7,676 W PTC; NEC 690.8 OCPD floor is 21.39 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 54.35 * (1 + (-0.257/100) * (-10 - 25)) = 59.24 V | OCPD = 1.56 * 13.71 = 21.39 A

Inputs from CEC Modules.csv for Philadelphia Solar PS-M156(HCBF)-585W: Voc=54.35 V, beta_Voc=-0.257%/C, Isc=13.71 A, STC=585.0 W, Area=2.77 m2.

**Result:** 10 panels max on 600 V (592.4 V); 14 panels for 8 kW (417 sq ft).

## What Are the Published CEC Specifications for Philadelphia Solar PS-M156(HCBF)-585W?

Official CEC datasheet figures for Philadelphia Solar PS-M156(HCBF)-585W (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Philadelphia Solar PS-M156(HCBF)-585W.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 585.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 548.3 W (93.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 54.35 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.71 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 45.57 V / 12.84 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.257 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.12% (2.77 m2) | Array roof footprint density |
| **Cell Count & Technology** | 78 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Philadelphia Solar PS-M156(HCBF)-585W Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Philadelphia Solar PS-M156(HCBF)-585W modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 11 | 6.43 kW | 328 sq ft | $1,609 | $2,721 |
| **8 kW Class** | 14 | 8.19 kW | 417 sq ft | $2,050 | $3,466 |
| **10 kW Class** | 18 | 10.53 kW | 537 sq ft | $2,636 | $4,457 |

## Which Sibling Wattage & Trim Variants Belong to This Philadelphia Solar Series?

Consolidated Philadelphia Solar wattage variants sharing the Philadelphia Solar PS-M156(HCBF)-585W mechanical and cell layout. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the Philadelphia Solar PS-M156(HCBF)-585W wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Philadelphia Solar PS-M156(HCBF)-575W** | 575.0 W | 538.7 W | 53.85 V | 45.15 V | 20.76% |
| **Philadelphia Solar PS-M156(HCBF)-580W** | 580.0 W | 543.5 W | 54.12 V | 45.35 V | 20.94% |
| **Philadelphia Solar PS-M156(HCBF)-585W** | 585.0 W | 548.3 W | 54.35 V | 45.57 V | 21.12% |
| **Philadelphia Solar PS-M156(HCBF)-590W** | 590.0 W | 553.2 W | 54.6 V | 45.82 V | 21.3% |
| **Philadelphia Solar PS-M156(HCBF)-595W** | 595.0 W | 558.0 W | 54.85 V | 46.04 V | 21.48% |

## How Many Philadelphia Solar PS-M156(HCBF)-585W Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Philadelphia Solar PS-M156(HCBF)-585W (59.24 V at 14 F).

Computed from Voc=54.35V and beta_Voc=-0.257%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 60.64 V | 9 panels | 545.8 V | 16 panels |
| **-10 C (14 F)** | 59.24 V | 10 panels | 592.4 V | 16 panels |
| **0 C (32 F)** | 57.84 V | 10 panels | 578.4 V | 17 panels |
| **25 C (77 F STC)** | 54.35 V | 11 panels | 597.9 V | 18 panels |

## Which Cross-Brand Solar Modules Compare Closest to Philadelphia Solar PS-M156(HCBF)-585W?

Competing CEC solar panels closest to Philadelphia Solar PS-M156(HCBF)-585W in nameplate wattage and Voc, starting with Boviet Solar Technology Co Ltd BVM7613M-585-H-HC-BF.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Boviet Solar Technology Co Ltd BVM7613M-585-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7613m-585-h-hc-bf/) Boviet Solar Technology Co Ltd | 585.0 W | Tie (0 W) | 54.07 V | 20.89% | 94.0% |
| [**Boviet Solar Technology Co Ltd BVM7613M-585-H-HC-BF-DG**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7613m-585-h-hc-bf-dg/) Boviet Solar Technology Co Ltd | 585.0 W | Tie (0 W) | 54.07 V | 20.89% | 94.1% |
| [**FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-585**](https://epri-peac.com/solar-equipment/modules/fs-green-energies-private-limited/fs-green-energies-private-limited-fst-m10144g-585/) FS GREEN ENERGIES PRIVATE LIMITED | 585.0 W | Tie (0 W) | 53.1 V | 22.85% | 95.0% |
| [**GOLDI SUN PRIVATE LIMITED GS10-T144-GF-585**](https://epri-peac.com/solar-equipment/modules/goldi-sun-private-limited/goldi-sun-private-limited-gs10-t144-gf-585/) GOLDI SUN PRIVATE LIMITED | 585.0 W | Tie (0 W) | 53.1 V | 22.67% | 93.8% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Philadelphia Solar PS-M156(HCBF)-585W?

Evaluate Philadelphia Solar PS-M156(HCBF)-585W (585.0 W STC, 54.35 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Philadelphia Solar PS-M156(HCBF)-585W reaches 60.64 V per panel—exceeding 9 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Philadelphia Solar PS-M156(HCBF)-585W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Philadelphia Solar PS-M156(HCBF)-585W 8 kW Residential Fit

Needs 14 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 9 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM7613M-585-H-HC-BF.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 548.3 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Philadelphia Solar PS-M156(HCBF)-585W by Philadelphia Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Philadelphia Solar PS-M156(HCBF)-585W?

Multiplying Philadelphia Solar PS-M156(HCBF)-585W's 13.71 A short-circuit current by 1.56 equals 21.39 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can Philadelphia Solar PS-M156(HCBF)-585W pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 59.24 V cold Voc at 14 F and handles 13.71 A Isc; string inverters cap Philadelphia Solar PS-M156(HCBF)-585W at 10 panels on 600 V.

### Is Philadelphia Solar PS-M156(HCBF)-585W eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Philadelphia Solar PS-M156(HCBF)-585W rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.

## Related Pages

Compare Philadelphia Solar equipment, Boviet Solar Technology Co Ltd BVM7613M-585-H-HC-BF specs, utility payback rates, and NEC string calculators alongside Philadelphia Solar PS-M156(HCBF)-585W.

[All Philadelphia Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/philadelphia-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Philadelphia Solar

- [All Philadelphia Solar Specs](https://epri-peac.com/solar-equipment/brands/philadelphia-solar/)
- [Philadelphia Solar PS-MNB156(HCBF)-650W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-mnb156-hcbf-650w/)
- [Philadelphia Solar PS-MNB156(HCBF)-635W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-mnb156-hcbf-635w/)
- [Philadelphia Solar PS-MNB156(HCBF)-620W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-mnb156-hcbf-620w/)
- [Philadelphia Solar PS-M156(HC)-605W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-m156-hc-605w/)
- [Philadelphia Solar PS-M156(HCBF)-GG-605W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-m156-hcbf-gg-605w/)