# Philadelphia Solar PS-M144(HCBF)-GG-535W — CEC Solar Module Specifications

Manufacturer: [**Philadelphia Solar**](https://epri-peac.com/solar-equipment/brands/philadelphia-solar/) Registry: **CEC Verified Engineering Specification**

Philadelphia Solar PS-M144(HCBF)-GG-535W is a 535.0 W STC (496.3 W PTC) Mono-c-Si solar module ranking #3,537 of 21,677 CEC listings (top 17.5%; higher than 82.5% of peers). It delivers 20.82% efficiency, 49.5 V Voc at 25 C, and 54.25 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 535.0 W

- **PTC Wattage** : 496.3 W

- **Voc @ 25C** : 49.5 V

- **Efficiency** : 20.82%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Philadelphia Solar PS-M144(HCBF)-GG-535W Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Philadelphia Solar PS-M144(HCBF)-GG-535W (Mono-c-Si) residential solar systems.

Homeowners evaluating Philadelphia Solar PS-M144(HCBF)-GG-535W need 12 panels for 6 kW or 15 panels (415 sq ft) for an 8 kW array—better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. Under NEC 690.7(A), beta_Voc (-0.274%/C) pushes open-circuit voltage to 54.25 V at 14 F and 55.6 V at -4 F. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.

## Where Does Philadelphia Solar PS-M144(HCBF)-GG-535W Fall Across Listed CEC Models?

Comparison of Philadelphia Solar PS-M144(HCBF)-GG-535W (535.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define Philadelphia Solar PS-M144(HCBF)-GG-535W?

Relative ranking of Philadelphia Solar PS-M144(HCBF)-GG-535W across nameplate watts, 92.8% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for Philadelphia Solar PS-M144(HCBF)-GG-535W?

Summary of Philadelphia Solar PS-M144(HCBF)-GG-535W output rank, 8 kW array size (15 panels), efficiency rating, and 600 V string limit.

Rank #3,537 / 21,677

### Top 17.5% STC Output

535.0 W STC (+150.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #7,176

### 20.82% Aperture Efficiency

Power density 208.2 W/m2 (0.91 percentage points above 19.91% CEC median). PTC/STC ratio: 92.8% (rank #10,898).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.25 V at -10 C (596.8 V string) and 55.6 V at -20 C (10 max).

 8 kW Reference Array

### 15 Panels = 8,025 W STC

Occupies 38.5 m2 (415 sq ft) producing 7,444 W PTC; NEC 690.8 OCPD floor is 21.29 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.5 * (1 + (-0.274/100) * (-10 - 25)) = 54.25 V | OCPD = 1.56 * 13.65 = 21.29 A

Inputs from CEC Modules.csv for Philadelphia Solar PS-M144(HCBF)-GG-535W: Voc=49.5 V, beta_Voc=-0.274%/C, Isc=13.65 A, STC=535.0 W, Area=2.57 m2.

**Result:** 11 panels max on 600 V (596.8 V); 15 panels for 8 kW (415 sq ft).

## What Are the Published CEC Specifications for Philadelphia Solar PS-M144(HCBF)-GG-535W?

Complete CEC test sheet for Philadelphia Solar PS-M144(HCBF)-GG-535W including Isc (13.65 A), Voc (49.5 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Philadelphia Solar PS-M144(HCBF)-GG-535W.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 535.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 496.3 W (92.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 49.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.65 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 41.72 V / 12.83 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.274 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.82% (2.57 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Philadelphia Solar PS-M144(HCBF)-GG-535W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Philadelphia Solar PS-M144(HCBF)-GG-535W.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 12 | 6.42 kW | 332 sq ft | $1,607 | $2,717 |
| **8 kW Class** | 15 | 8.03 kW | 415 sq ft | $2,010 | $3,398 |
| **10 kW Class** | 19 | 10.16 kW | 526 sq ft | $2,543 | $4,300 |

## Which Sibling Wattage & Trim Variants Belong to This Philadelphia Solar Series?

Related Philadelphia Solar power steps and black/silver trims consolidated into this Philadelphia Solar PS-M144(HCBF)-GG-535W series guide.

Sibling CEC listings grouped into the Philadelphia Solar PS-M144(HCBF)-GG-535W wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Philadelphia Solar PS-M144(HCBF)-GG-525W** | 525.0 W | 486.8 W | 48.95 V | 41.21 V | 20.43% |
| **Philadelphia Solar PS-M144(HCBF)-GG-530W** | 530.0 W | 491.6 W | 49.2 V | 41.46 V | 20.62% |
| **Philadelphia Solar PS-M144(HCBF)-GG-535W** | 535.0 W | 496.3 W | 49.5 V | 41.72 V | 20.82% |
| **Philadelphia Solar PS-M144(HCBF)-GG-540W** | 540.0 W | 501.1 W | 49.8 V | 42.0 V | 21.01% |
| **Philadelphia Solar PS-M144(HCBF)-GG-545W** | 545.0 W | 505.9 W | 50.1 V | 42.26 V | 21.21% |

## How Many Philadelphia Solar PS-M144(HCBF)-GG-535W Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Philadelphia Solar PS-M144(HCBF)-GG-535W (49.5 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=49.5V and beta_Voc=-0.274%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 55.6 V | 10 panels | 556.0 V | 17 panels |
| **-10 C (14 F)** | 54.25 V | 11 panels | 596.8 V | 18 panels |
| **0 C (32 F)** | 52.89 V | 11 panels | 581.8 V | 18 panels |
| **25 C (77 F STC)** | 49.5 V | 12 panels | 594.0 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to Philadelphia Solar PS-M144(HCBF)-GG-535W?

Four comparable CEC modules such as G-Star Pte Ltd GSP7G72M(H)535WT (535.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**G-Star Pte Ltd GSP7G72M(H)535WT**](https://epri-peac.com/solar-equipment/modules/g-star-pte-ltd/g-star-pte-ltd-gsp7g72m-h-535wt/) G-Star Pte Ltd | 535.0 W | Tie (0 W) | 49.46 V | 20.9% | 94.0% |
| [**Bila Solar Inc AA535US-6x24GG**](https://epri-peac.com/solar-equipment/modules/bila-solar-inc/bila-solar-inc-aa535us-6x24gg/) Bila Solar Inc | 535.0 W | Tie (0 W) | 49.45 V | 21.31% | 92.8% |
| [**ES Foundry Corp ES-DP8-H72-535**](https://epri-peac.com/solar-equipment/modules/es-foundry-corp/es-foundry-corp-es-dp8-h72-535/) ES Foundry Corp | 535.0 W | Tie (0 W) | 49.45 V | 20.9% | 93.8% |
| [**Hanersun Energy Co Ltd HN18-72HT535W**](https://epri-peac.com/solar-equipment/modules/hanersun-energy-co-ltd/hanersun-energy-co-ltd-hn18-72ht535w/) Hanersun Energy Co Ltd | 535.0 W | Tie (0 W) | 49.45 V | 21.23% | 94.4% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Philadelphia Solar PS-M144(HCBF)-GG-535W?

Evaluate Philadelphia Solar PS-M144(HCBF)-GG-535W (535.0 W STC, 49.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Philadelphia Solar PS-M144(HCBF)-GG-535W reaches 55.6 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 415 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Philadelphia Solar PS-M144(HCBF)-GG-535W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Philadelphia Solar PS-M144(HCBF)-GG-535W 8 kW Residential Fit

Needs 15 modules (415 sq ft) with a 25 A string OCPD, offsetting ~$2,010/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare G-Star Pte Ltd GSP7G72M(H)535WT.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 496.3 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Philadelphia Solar PS-M144(HCBF)-GG-535W by Philadelphia Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Philadelphia Solar PS-M144(HCBF)-GG-535W PTC wattage (496.3 W) lower than STC (535.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 496.3 W PTC (92.8% retention) across Philadelphia Solar PS-M144(HCBF)-GG-535W's 2.57 m2 aperture.

### Who should skip Philadelphia Solar PS-M144(HCBF)-GG-535W on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 15 Philadelphia Solar PS-M144(HCBF)-GG-535W panels (415 sq ft) leave unusable roof gaps vs. G-Star Pte Ltd GSP7G72M(H)535WT.

### What is the 1,000 V commercial string limit for Philadelphia Solar PS-M144(HCBF)-GG-535W?

On 1,000 V commercial inverters at -10 C (54.25 V cold Voc), Philadelphia Solar PS-M144(HCBF)-GG-535W fits up to 18 panels per series string.

## Related Pages

Compare Philadelphia Solar equipment, G-Star Pte Ltd GSP7G72M(H)535WT specs, utility payback rates, and NEC string calculators alongside Philadelphia Solar PS-M144(HCBF)-GG-535W.

[All Philadelphia Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/philadelphia-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Philadelphia Solar

- [All Philadelphia Solar Specs](https://epri-peac.com/solar-equipment/brands/philadelphia-solar/)
- [Philadelphia Solar PS-MNB156(HCBF)-650W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-mnb156-hcbf-650w/)
- [Philadelphia Solar PS-MNB156(HCBF)-635W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-mnb156-hcbf-635w/)
- [Philadelphia Solar PS-MNB156(HCBF)-620W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-mnb156-hcbf-620w/)
- [Philadelphia Solar PS-M156(HC)-605W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-m156-hc-605w/)
- [Philadelphia Solar PS-M156(HCBF)-GG-605W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-m156-hcbf-gg-605w/)