---
title: "Philadelphia Solar Specs philadelphia-s #3"
url: https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-m144-hcbf-540w/
description: "CEC datasheet for Philadelphia Solar PS-M144(HCBF)-540W: 540.0W STC, 49.8V Voc, 15-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Philadelphia Solar PS-M144(HCBF)-540W — CEC Solar Module Specifications

Manufacturer: [**Philadelphia Solar**](https://epri-peac.com/solar-equipment/brands/philadelphia-solar/) Registry: **CEC Verified Engineering Specification**

Philadelphia Solar PS-M144(HCBF)-540W is a 540.0 W STC (500.0 W PTC) Mono-c-Si solar module ranking #3,265 of 21,677 CEC listings (top 16.3%; higher than 83.7% of peers). It delivers 21.09% efficiency, 49.8 V Voc at 25 C, and 54.37 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 540.0 W

- **PTC Wattage** : 500.0 W

- **Voc @ 25C** : 49.8 V

- **Efficiency** : 21.09%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Philadelphia Solar PS-M144(HCBF)-540W Compare Against Peer CEC Listings?

Solar engineering breakdown for Philadelphia Solar PS-M144(HCBF)-540W: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 540.0 W STC and 500.0 W PTC, Philadelphia Solar PS-M144(HCBF)-540W sits +155.0 W vs all-CEC median (top 16.3%; higher than 83.7% of peers) among 21,677 listed modules. Power density reaches 210.9 W/m2 (1.18 percentage points above 19.91% CEC median). Higher 49.8 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 18 panels in series. Alternative peer ASTORIOS Holding Inc ASTR144BDG-540W-US rates 540.0 W.

## Where Does Philadelphia Solar PS-M144(HCBF)-540W Fall Across Listed CEC Models?

Distribution marker showing Philadelphia Solar PS-M144(HCBF)-540W (540.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define Philadelphia Solar PS-M144(HCBF)-540W?

Dataset percentiles tracking Philadelphia Solar PS-M144(HCBF)-540W power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for Philadelphia Solar PS-M144(HCBF)-540W?

Benchmark highlights for Philadelphia Solar PS-M144(HCBF)-540W covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #3,265 / 21,677

### Top 16.3% STC Output

540.0 W STC (+155.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,965

### 21.09% Aperture Efficiency

Power density 210.9 W/m2 (1.18 percentage points above 19.91% CEC median). PTC/STC ratio: 92.6% (rank #11,981).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.37 V at -10 C (598.1 V string) and 55.67 V at -20 C (10 max).

 8 kW Reference Array

### 15 Panels = 8,100 W STC

Occupies 38.4 m2 (413 sq ft) producing 7,500 W PTC; NEC 690.8 OCPD floor is 21.37 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.8 * (1 + (-0.262/100) * (-10 - 25)) = 54.37 V | OCPD = 1.56 * 13.7 = 21.37 A

Inputs from CEC Modules.csv for Philadelphia Solar PS-M144(HCBF)-540W: Voc=49.8 V, beta_Voc=-0.262%/C, Isc=13.7 A, STC=540.0 W, Area=2.56 m2.

**Result:** 11 panels max on 600 V (598.1 V); 15 panels for 8 kW (413 sq ft).

## What Are the Published CEC Specifications for Philadelphia Solar PS-M144(HCBF)-540W?

Official CEC datasheet figures for Philadelphia Solar PS-M144(HCBF)-540W (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Philadelphia Solar PS-M144(HCBF)-540W.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 540.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 500.0 W (92.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 49.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.7 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 42.0 V / 12.86 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.262 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.09% (2.56 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Philadelphia Solar PS-M144(HCBF)-540W Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Philadelphia Solar PS-M144(HCBF)-540W modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 12 | 6.48 kW | 331 sq ft | $1,622 | $2,742 |
| **8 kW Class** | 15 | 8.1 kW | 413 sq ft | $2,027 | $3,428 |
| **10 kW Class** | 19 | 10.26 kW | 524 sq ft | $2,568 | $4,342 |

## Which Sibling Wattage & Trim Variants Belong to This Philadelphia Solar Series?

Consolidated Philadelphia Solar wattage variants sharing the Philadelphia Solar PS-M144(HCBF)-540W mechanical and cell layout. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the Philadelphia Solar PS-M144(HCBF)-540W wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Philadelphia Solar PS-M144(HCBF)-530W** | 530.0 W | 490.5 W | 49.2 V | 41.46 V | 20.7% |
| **Philadelphia Solar PS-M144(HCBF)-535W** | 535.0 W | 495.3 W | 49.5 V | 41.72 V | 20.9% |
| **Philadelphia Solar PS-M144(HCBF)-540W** | 540.0 W | 500.0 W | 49.8 V | 42.0 V | 21.09% |
| **Philadelphia Solar PS-M144(HCBF)-545W** | 545.0 W | 504.8 W | 50.1 V | 42.26 V | 21.29% |

## How Many Philadelphia Solar PS-M144(HCBF)-540W Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Philadelphia Solar PS-M144(HCBF)-540W (54.37 V at 14 F).

Computed from Voc=49.8V and beta_Voc=-0.262%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 55.67 V | 10 panels | 556.7 V | 17 panels |
| **-10 C (14 F)** | 54.37 V | 11 panels | 598.1 V | 18 panels |
| **0 C (32 F)** | 53.06 V | 11 panels | 583.7 V | 18 panels |
| **25 C (77 F STC)** | 49.8 V | 12 panels | 597.6 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to Philadelphia Solar PS-M144(HCBF)-540W?

Competing CEC solar panels closest to Philadelphia Solar PS-M144(HCBF)-540W in nameplate wattage and Voc, starting with ASTORIOS Holding Inc ASTR144BDG-540W-US.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**ASTORIOS Holding Inc ASTR144BDG-540W-US**](https://epri-peac.com/solar-equipment/modules/astorios-holding-inc/astorios-holding-inc-astr144bdg-540w-us/) ASTORIOS Holding Inc | 540.0 W | Tie (0 W) | 49.8 V | 20.93% | 93.6% |
| [**Energy America LLC EA-ZLK7-SHDB144-540/M**](https://epri-peac.com/solar-equipment/modules/energy-america-llc/energy-america-llc-ea-zlk7-shdb144-540-m/) Energy America LLC | 540.0 W | Tie (0 W) | 49.8 V | 20.93% | 93.6% |
| [**Hansol Technics Co Ltd HA540XD-GNEA0**](https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-ha540xd-gnea0/) Hansol Technics Co Ltd | 540.0 W | Tie (0 W) | 49.8 V | 21.09% | 94.4% |
| [**Hounen Solar America Inc HNM7-SHDB144-540/M**](https://epri-peac.com/solar-equipment/modules/hounen-solar-america-inc/hounen-solar-america-inc-hnm7-shdb144-540-m/) Hounen Solar America Inc | 540.0 W | Tie (0 W) | 49.8 V | 20.93% | 93.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Philadelphia Solar PS-M144(HCBF)-540W?

Evaluate Philadelphia Solar PS-M144(HCBF)-540W (540.0 W STC, 49.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Philadelphia Solar PS-M144(HCBF)-540W reaches 55.67 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 413 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Philadelphia Solar PS-M144(HCBF)-540W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Philadelphia Solar PS-M144(HCBF)-540W 8 kW Residential Fit

Needs 15 modules (413 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare ASTORIOS Holding Inc ASTR144BDG-540W-US.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 500.0 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Philadelphia Solar PS-M144(HCBF)-540W by Philadelphia Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Philadelphia Solar PS-M144(HCBF)-540W panels fit on a 600 V winter solar string?

At -10 C (14 F), Philadelphia Solar PS-M144(HCBF)-540W cold Voc rises from 49.8 V to 54.37 V (beta_Voc -0.262%/C), capping a 600 V string at 11 panels (598.1 V).

### How much roof area does an 8 kW array of Philadelphia Solar PS-M144(HCBF)-540W need?

An 8 kW DC system uses 15 Philadelphia Solar PS-M144(HCBF)-540W modules (8,100 W STC / 7,500 W PTC), covering roughly 413 sq ft and saving ~$2,027/yr at 18.54 c/kWh.

### How does Philadelphia Solar PS-M144(HCBF)-540W compare against ASTORIOS Holding Inc ASTR144BDG-540W-US?

Philadelphia Solar PS-M144(HCBF)-540W outputs 540.0 W STC (49.8 V Voc, rank #3,265 of 21,677), while ASTORIOS Holding Inc ASTR144BDG-540W-US delivers 540.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Philadelphia Solar equipment, ASTORIOS Holding Inc ASTR144BDG-540W-US specs, utility payback rates, and NEC string calculators alongside Philadelphia Solar PS-M144(HCBF)-540W.

[All Philadelphia Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/philadelphia-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Philadelphia Solar

- [All Philadelphia Solar Specs](https://epri-peac.com/solar-equipment/brands/philadelphia-solar/)
- [Philadelphia Solar PS-MNB156(HCBF)-650W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-mnb156-hcbf-650w/)
- [Philadelphia Solar PS-MNB156(HCBF)-635W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-mnb156-hcbf-635w/)
- [Philadelphia Solar PS-MNB156(HCBF)-620W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-mnb156-hcbf-620w/)
- [Philadelphia Solar PS-M156(HC)-605W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-m156-hc-605w/)
- [Philadelphia Solar PS-M156(HCBF)-GG-605W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-m156-hcbf-gg-605w/)
