title: "Philadelphia Solar Specs (410.0W, 37.68V Voc)"
url: https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-m108-hcbf-410w/
description: "CEC datasheet for Philadelphia Solar PS-M108(HCBF)-410W: 410.0W STC, 37.68V Voc, 20-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Philadelphia Solar PS-M108(HCBF)-410W — CEC Solar Module Specifications

Manufacturer: [**Philadelphia Solar**](https://epri-peac.com/solar-equipment/brands/philadelphia-solar/) Registry: **CEC Verified Engineering Specification**

Philadelphia Solar PS-M108(HCBF)-410W is a 410.0 W STC (386.1 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.24% efficiency, 37.68 V Voc at 25 C, and 41.04 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 410.0 W

- **PTC Wattage** : 386.1 W

- **Voc @ 25C** : 37.68 V

- **Efficiency** : 21.24%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Philadelphia Solar PS-M108(HCBF)-410W Compare Against Peer CEC Listings?

Solar engineering breakdown for Philadelphia Solar PS-M108(HCBF)-410W: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from Philadelphia Solar and peers, Philadelphia Solar PS-M108(HCBF)-410W stands equal to the 410.0 W Mono-c-Si median and strong 94.2% PTC-to-STC heat retention (#3,689 of 21,677). Sizing 6 kW (15 panels) to 10 kW (25 panels) yields $1,539-$2,565/yr in baseline US bill offset. Lower 37.68 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

## Where Does Philadelphia Solar PS-M108(HCBF)-410W Fall Across Listed CEC Models?

Distribution marker showing Philadelphia Solar PS-M108(HCBF)-410W (410.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define Philadelphia Solar PS-M108(HCBF)-410W?

Dataset percentiles tracking Philadelphia Solar PS-M108(HCBF)-410W power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for Philadelphia Solar PS-M108(HCBF)-410W?

Benchmark highlights for Philadelphia Solar PS-M108(HCBF)-410W covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #8,539 / 21,677

### Top 41.3% STC Output

410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,440

### 21.24% Aperture Efficiency

Power density 212.4 W/m2 (1.33 percentage points above 19.91% CEC median). PTC/STC ratio: 94.2% (rank #3,689).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.04 V at -10 C (574.6 V string) and 42.0 V at -20 C (14 max).

 8 kW Reference Array

### 20 Panels = 8,200 W STC

Occupies 38.6 m2 (415 sq ft) producing 7,722 W PTC; NEC 690.8 OCPD floor is 21.57 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.68 * (1 + (-0.255/100) * (-10 - 25)) = 41.04 V | OCPD = 1.56 * 13.83 = 21.57 A

Inputs from CEC Modules.csv for Philadelphia Solar PS-M108(HCBF)-410W: Voc=37.68 V, beta_Voc=-0.255%/C, Isc=13.83 A, STC=410.0 W, Area=1.93 m2.

**Result:** 14 panels max on 600 V (574.6 V); 20 panels for 8 kW (415 sq ft).

## What Are the Published CEC Specifications for Philadelphia Solar PS-M108(HCBF)-410W?

Official CEC datasheet figures for Philadelphia Solar PS-M108(HCBF)-410W (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Philadelphia Solar PS-M108(HCBF)-410W.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 410.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 386.1 W (94.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 37.68 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.83 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 31.17 V / 13.18 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.255 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.24% (1.93 m2) | Array roof footprint density |
| **Cell Count & Technology** | 54 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Philadelphia Solar PS-M108(HCBF)-410W Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Philadelphia Solar PS-M108(HCBF)-410W modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 15 | 6.15 kW | 312 sq ft | $1,539 | $2,603 |
| **8 kW Class** | 20 | 8.2 kW | 415 sq ft | $2,052 | $3,470 |
| **10 kW Class** | 25 | 10.25 kW | 519 sq ft | $2,565 | $4,338 |

## Which Sibling Wattage & Trim Variants Belong to This Philadelphia Solar Series?

Consolidated Philadelphia Solar wattage variants sharing the Philadelphia Solar PS-M108(HCBF)-410W mechanical and cell layout. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the Philadelphia Solar PS-M108(HCBF)-410W wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Philadelphia Solar PS-M108(HCBF)-400W** | 400.0 W | 376.5 W | 37.08 V | 30.59 V | 20.73% |
| **Philadelphia Solar PS-M108(HCBF)-405W** | 405.0 W | 381.3 W | 37.38 V | 30.87 V | 20.98% |
| **Philadelphia Solar PS-M108(HCBF)-410W** | 410.0 W | 386.1 W | 37.68 V | 31.17 V | 21.24% |
| **Philadelphia Solar PS-M108(HCBF)-415W** | 415.0 W | 391.0 W | 37.98 V | 31.43 V | 21.5% |

## How Many Philadelphia Solar PS-M108(HCBF)-410W Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Philadelphia Solar PS-M108(HCBF)-410W (41.04 V at 14 F).

Computed from Voc=37.68V and beta_Voc=-0.255%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 42.0 V | 14 panels | 588.0 V | 23 panels |
| **-10 C (14 F)** | 41.04 V | 14 panels | 574.6 V | 24 panels |
| **0 C (32 F)** | 40.08 V | 14 panels | 561.1 V | 24 panels |
| **25 C (77 F STC)** | 37.68 V | 15 panels | 565.2 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to Philadelphia Solar PS-M108(HCBF)-410W?

Competing CEC solar panels closest to Philadelphia Solar PS-M108(HCBF)-410W in nameplate wattage and Voc, starting with ASTORIOS Holding Inc ASTR108BDG-410W-US.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**ASTORIOS Holding Inc ASTR108BDG-410W-US**](https://epri-peac.com/solar-equipment/modules/astorios-holding-inc/astorios-holding-inc-astr108bdg-410w-us/) ASTORIOS Holding Inc | 410.0 W | Tie (0 W) | 37.5 V | 21.13% | 93.0% |
| [**AXITEC AC-410MBT/108US**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-410mbt-108us/) AXITEC | 410.0 W | Tie (0 W) | 37.5 V | 21.13% | 93.0% |
| [**CSI Solar Co Ltd CS6R-410MB**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6r-410mb/) CSI Solar Co Ltd | 410.0 W | Tie (0 W) | 38.0 V | 21.69% | 94.2% |
| [**CSI Solar Co Ltd CS6R-410MB-HL**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6r-410mb-hl/) CSI Solar Co Ltd | 410.0 W | Tie (0 W) | 38.0 V | 21.69% | 94.2% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Philadelphia Solar PS-M108(HCBF)-410W?

Evaluate Philadelphia Solar PS-M108(HCBF)-410W (410.0 W STC, 37.68 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Philadelphia Solar PS-M108(HCBF)-410W reaches 42.0 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 415 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (415 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Philadelphia Solar PS-M108(HCBF)-410W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Philadelphia Solar PS-M108(HCBF)-410W 8 kW Residential Fit

Needs 20 modules (415 sq ft) with a 25 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare ASTORIOS Holding Inc ASTR108BDG-410W-US.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 386.1 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Philadelphia Solar PS-M108(HCBF)-410W by Philadelphia Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Philadelphia Solar PS-M108(HCBF)-410W?

Multiplying Philadelphia Solar PS-M108(HCBF)-410W's 13.83 A short-circuit current by 1.56 equals 21.57 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can Philadelphia Solar PS-M108(HCBF)-410W pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 41.04 V cold Voc at 14 F and handles 13.83 A Isc; string inverters cap Philadelphia Solar PS-M108(HCBF)-410W at 14 panels on 600 V.

### Is Philadelphia Solar PS-M108(HCBF)-410W eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Philadelphia Solar PS-M108(HCBF)-410W rely on utility bill offset (~$2,052/yr at 8 kW) rather than 25D.

## Related Pages

Compare Philadelphia Solar equipment, ASTORIOS Holding Inc ASTR108BDG-410W-US specs, utility payback rates, and NEC string calculators alongside Philadelphia Solar PS-M108(HCBF)-410W.

[All Philadelphia Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/philadelphia-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Philadelphia Solar

- [All Philadelphia Solar Specs](https://epri-peac.com/solar-equipment/brands/philadelphia-solar/)
- [Philadelphia Solar PS-MNB156(HCBF)-650W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-mnb156-hcbf-650w/)
- [Philadelphia Solar PS-MNB156(HCBF)-635W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-mnb156-hcbf-635w/)
- [Philadelphia Solar PS-MNB156(HCBF)-620W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-mnb156-hcbf-620w/)
- [Philadelphia Solar PS-M156(HC)-605W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-m156-hc-605w/)
- [Philadelphia Solar PS-M156(HCBF)-GG-605W](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-m156-hcbf-gg-605w/)