CEC PV Module

# Perlight Solar PLM-215P-60 — CEC Solar Module Specifications

Manufacturer: [**Perlight Solar**](https://epri-peac.com/solar-equipment/brands/perlight-solar/) Registry: **CEC Verified Engineering Specification**

Perlight Solar PLM-215P-60 is a 215.0 W STC (187.3 W PTC) Multi-c-Si solar module ranking #20,859 of 21,677 CEC listings (below all-CEC median; higher than 3.5% of peers). It delivers 13.14% efficiency, 36.6 V Voc at 25 C, and 41.78 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 215.0 W

- **PTC Wattage** : 187.3 W

- **Voc @ 25C** : 36.6 V

- **Efficiency** : 13.14%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Perlight Solar PLM-215P-60 Compare Against Peer CEC Listings?

Solar engineering breakdown for Perlight Solar PLM-215P-60: PTC thermal retention, roof footprint, and cold Voc string bounds. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Measured at 215.0 W STC and 187.3 W PTC, Perlight Solar PLM-215P-60 sits -170.0 W vs all-CEC median (below all-CEC median; higher than 3.5% of peers) among 21,677 listed modules. Power density reaches 131.3 W/m2 (6.77 percentage points below 19.91% CEC median). Lower 36.6 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 23 panels in series. Alternative peer APOS Energy AP215 rates 215.0 W.

## Where Does Perlight Solar PLM-215P-60 Fall Across Listed CEC Models?

Distribution marker showing Perlight Solar PLM-215P-60 (215.0 W) relative to the 385.0 W all-CEC solar panel median. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

## What Dataset Percentiles Define Perlight Solar PLM-215P-60?

Dataset percentiles tracking Perlight Solar PLM-215P-60 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

## What Do the Dataset Ranks Show for Perlight Solar PLM-215P-60?

Benchmark highlights for Perlight Solar PLM-215P-60 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Rank #20,859 / 21,677

### 215.0 W STC · Higher Than 3.5%

215.0 W STC (-170.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,368

### 13.14% Aperture Efficiency

Power density 131.3 W/m2 (6.77 percentage points below 19.91% CEC median). PTC/STC ratio: 87.1% (rank #21,587).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.78 V at -10 C (584.9 V string) and 43.25 V at -20 C (13 max).

 8 kW Reference Array

### 38 Panels = 8,170 W STC

Occupies 62.2 m2 (670 sq ft) producing 7,117 W PTC; NEC 690.8 OCPD floor is 12.37 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.6 * (1 + (-0.404/100) * (-10 - 25)) = 41.78 V | OCPD = 1.56 * 7.93 = 12.37 A

Inputs from CEC Modules.csv for Perlight Solar PLM-215P-60: Voc=36.6 V, beta_Voc=-0.404%/C, Isc=7.93 A, STC=215.0 W, Area=1.637 m2.

**Result:** 14 panels max on 600 V (584.9 V); 38 panels for 8 kW (670 sq ft).

## What Are the Published CEC Specifications for Perlight Solar PLM-215P-60?

Official CEC datasheet figures for Perlight Solar PLM-215P-60 (Multi-c-Si) used in utility interconnection and permit reviews. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Official California Energy Commission (NREL SAM) test parameters for Perlight Solar PLM-215P-60.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 215.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 187.3 W (87.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 36.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 7.93 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 29.5 V / 7.29 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.404 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 13.14% (1.637 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Perlight Solar PLM-215P-60 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Perlight Solar PLM-215P-60 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 28 | 6.02 kW | 493 sq ft | $1,507 | $2,548 |
| **8 kW Class** | 38 | 8.17 kW | 670 sq ft | $2,045 | $3,458 |
| **10 kW Class** | 47 | 10.11 kW | 828 sq ft | $2,530 | $4,279 |

## How Many Perlight Solar PLM-215P-60 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Perlight Solar PLM-215P-60 (41.78 V at 14 F).

Computed from Voc=36.6V and beta_Voc=-0.404%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 43.25 V | 13 panels | 562.2 V | 23 panels |
| **-10 C (14 F)** | 41.78 V | 14 panels | 584.9 V | 23 panels |
| **0 C (32 F)** | 40.3 V | 14 panels | 564.2 V | 24 panels |
| **25 C (77 F STC)** | 36.6 V | 16 panels | 585.6 V | 27 panels |

## Which Cross-Brand Solar Modules Compare Closest to Perlight Solar PLM-215P-60?

Competing CEC solar panels closest to Perlight Solar PLM-215P-60 in nameplate wattage and Voc, starting with APOS Energy AP215.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**APOS Energy AP215**](https://epri-peac.com/solar-equipment/modules/apos-energy/apos-energy-ap215/) APOS Energy | 215.0 W | Tie (0 W) | 36.79 V | 12.96% | 88.8% |
| [**CSI Solar Co Ltd CS6P-215M**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-215m/) CSI Solar Co Ltd | 215.0 W | Tie (0 W) | 36.8 V | 13.88% | 90.2% |
| [**Anji Dasol Solar Energy Science & Technology DS-A4-215**](https://epri-peac.com/solar-equipment/modules/anji-dasol-solar-energy-science-technology/anji-dasol-solar-energy-science-technology-ds-a4-215/) Anji Dasol Solar Energy Science & Technology | 215.0 W | Tie (0 W) | 36.3 V | 13.06% | 87.1% |
| [**Advance Power API-P215**](https://epri-peac.com/solar-equipment/modules/advance-power/advance-power-api-p215/) Advance Power | 215.0 W | Tie (0 W) | 36.0 V | 13.13% | 89.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Perlight Solar PLM-215P-60?

Evaluate Perlight Solar PLM-215P-60 (215.0 W STC, 36.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Perlight Solar PLM-215P-60 reaches 43.25 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 38 panels for an 8 kW build require 670 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 38 panels (670 sq ft).
- 2026 tax credit baseline: cash residential installs of Perlight Solar PLM-215P-60 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Perlight Solar PLM-215P-60 8 kW Residential Fit

Needs 38 modules (670 sq ft) with a 15 A string OCPD, offsetting ~$2,045/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare APOS Energy AP215.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 187.3 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Perlight Solar PLM-215P-60 by Perlight Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Perlight Solar PLM-215P-60 panels fit on a 600 V winter solar string?

At -10 C (14 F), Perlight Solar PLM-215P-60 cold Voc rises from 36.6 V to 41.78 V (beta_Voc -0.404%/C), capping a 600 V string at 14 panels (584.9 V).

### How much roof area does an 8 kW array of Perlight Solar PLM-215P-60 need?

An 8 kW DC system uses 38 Perlight Solar PLM-215P-60 modules (8,170 W STC / 7,117 W PTC), covering roughly 670 sq ft and saving ~$2,045/yr at 18.54 c/kWh.

### How does Perlight Solar PLM-215P-60 compare against APOS Energy AP215?

Perlight Solar PLM-215P-60 outputs 215.0 W STC (36.6 V Voc, rank #20,859 of 21,677), while APOS Energy AP215 delivers 215.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Perlight Solar equipment, APOS Energy AP215 specs, utility payback rates, and NEC string calculators alongside Perlight Solar PLM-215P-60.

[All Perlight Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/perlight-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Perlight Solar

- [All Perlight Solar Specs](https://epri-peac.com/solar-equipment/brands/perlight-solar/)
- [Perlight Solar PLM-290P-72](https://epri-peac.com/solar-equipment/modules/perlight-solar/perlight-solar-plm-290p-72/)
- [Perlight Solar PLM-270P-72](https://epri-peac.com/solar-equipment/modules/perlight-solar/perlight-solar-plm-270p-72/)
- [Perlight Solar PLM-235P-60](https://epri-peac.com/solar-equipment/modules/perlight-solar/perlight-solar-plm-235p-60/)