title: "PANASONIC CORPORATION OF NORTH Specs (390.0W, 48.6V Voc)"
url: https://epri-peac.com/solar-equipment/modules/panasonic-corporation-of-north-america/panasonic-corporation-of-north-america-evpv390h/
description: "CEC datasheet for PANASONIC CORPORATION OF NORTH AMERICA EVPV390H: 390.0W STC, 48.6V Voc, 21-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# PANASONIC CORPORATION OF NORTH AMERICA EVPV390H — CEC Solar Module Specifications

Manufacturer: [**PANASONIC CORPORATION OF NORTH AMERICA**](https://epri-peac.com/solar-equipment/brands/panasonic-corporation-of-north-america/) Registry: **CEC Verified Engineering Specification**

PANASONIC CORPORATION OF NORTH AMERICA EVPV390H is a 390.0 W STC (372.2 W PTC) Mono-c-Si solar module ranking #10,321 of 21,677 CEC listings (top 49.5%; higher than 50.5% of peers). It delivers 21.79% efficiency, 48.6 V Voc at 25 C, and 52.5 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 390.0 W

- **PTC Wattage** : 372.2 W

- **Voc @ 25C** : 48.6 V

- **Efficiency** : 21.79%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does PANASONIC CORPORATION OF NORTH AMERICA EVPV390H Compare Against Peer CEC Listings?

Engineering position of PANASONIC CORPORATION OF NORTH AMERICA EVPV390H (390.0 W STC) vs. CSI Solar Co Ltd CS3U-390MS across 5,889 CEC Mono-c-Si solar modules.

Built with 66 Mono-c-Si cells, PANASONIC CORPORATION OF NORTH AMERICA EVPV390H pairs strong 95.4% PTC-to-STC heat retention (#141 of 21,677) with 48.6 V nominal Voc. An 8 kW residential build (8,190 W DC, 7,816 W PTC) saves ~$2,050/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer CSI Solar Co Ltd CS3U-390MS offers a 390.0 W alternative.

## Where Does PANASONIC CORPORATION OF NORTH AMERICA EVPV390H Fall Across Listed CEC Models?

Plots PANASONIC CORPORATION OF NORTH AMERICA EVPV390H at 390.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define PANASONIC CORPORATION OF NORTH AMERICA EVPV390H?

Benchmarks PANASONIC CORPORATION OF NORTH AMERICA EVPV390H on STC wattage, thermal PTC/STC retention, and 21.79 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for PANASONIC CORPORATION OF NORTH AMERICA EVPV390H?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for PANASONIC CORPORATION OF NORTH AMERICA EVPV390H by PANASONIC CORPORATION OF NORTH AMERICA.

Rank #10,321 / 21,677

### Top 49.5% STC Output

390.0 W STC (+5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,590

### 21.79% Aperture Efficiency

Power density 217.9 W/m2 (1.88 percentage points above 19.91% CEC median). PTC/STC ratio: 95.4% (rank #141).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.5 V at -10 C (577.5 V string) and 53.61 V at -20 C (11 max).

 8 kW Reference Array

### 21 Panels = 8,190 W STC

Occupies 37.6 m2 (405 sq ft) producing 7,816 W PTC; NEC 690.8 OCPD floor is 15.9 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.6 * (1 + (-0.229/100) * (-10 - 25)) = 52.5 V | OCPD = 1.56 * 10.19 = 15.9 A

Inputs from CEC Modules.csv for PANASONIC CORPORATION OF NORTH AMERICA EVPV390H: Voc=48.6 V, beta_Voc=-0.229%/C, Isc=10.19 A, STC=390.0 W, Area=1.79 m2.

**Result:** 11 panels max on 600 V (577.5 V); 21 panels for 8 kW (405 sq ft).

## What Are the Published CEC Specifications for PANASONIC CORPORATION OF NORTH AMERICA EVPV390H?

Laboratory test ratings recorded for PANASONIC CORPORATION OF NORTH AMERICA EVPV390H (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for PANASONIC CORPORATION OF NORTH AMERICA EVPV390H.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 390.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 372.2 W (95.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 48.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 10.19 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 41.5 V / 9.4 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.229 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.79% (1.79 m2) | Array roof footprint density |
| **Cell Count & Technology** | 66 cells (Mono-c-Si) | Monofacial backsheet |

## How Many PANASONIC CORPORATION OF NORTH AMERICA EVPV390H Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (405 sq ft at 8 kW), and estimated Year-1 electric bill offset for PANASONIC CORPORATION OF NORTH AMERICA EVPV390H.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 16 | 6.24 kW | 308 sq ft | $1,562 | $2,641 |
| **8 kW Class** | 21 | 8.19 kW | 405 sq ft | $2,050 | $3,466 |
| **10 kW Class** | 26 | 10.14 kW | 501 sq ft | $2,538 | $4,292 |

## How Many PANASONIC CORPORATION OF NORTH AMERICA EVPV390H Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for PANASONIC CORPORATION OF NORTH AMERICA EVPV390H (beta_Voc -0.229%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=48.6V and beta_Voc=-0.229%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 53.61 V | 11 panels | 589.7 V | 18 panels |
| **-10 C (14 F)** | 52.5 V | 11 panels | 577.5 V | 19 panels |
| **0 C (32 F)** | 51.38 V | 11 panels | 565.2 V | 19 panels |
| **25 C (77 F STC)** | 48.6 V | 12 panels | 583.2 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to PANASONIC CORPORATION OF NORTH AMERICA EVPV390H?

Closest cross-brand CEC competitors to PANASONIC CORPORATION OF NORTH AMERICA EVPV390H matched near 390.0 W STC and 48.6 V Voc, led by CSI Solar Co Ltd CS3U-390MS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS3U-390MS**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3u-390ms/) CSI Solar Co Ltd | 390.0 W | Tie (0 W) | 48.2 V | 20.31% | 93.2% |
| [**Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-395W**](https://epri-peac.com/solar-equipment/modules/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd-as-6m-bhc-395w/) Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd | 395.0 W | +5.0 W | 48.7 V | 20.26% | 92.9% |
| [**Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-395W**](https://epri-peac.com/solar-equipment/modules/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd-as-6m-hc-395w/) Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd | 395.0 W | +5.0 W | 48.7 V | 20.68% | 92.5% |
| [**Boviet Solar Technology Co Ltd BVM6612M-385-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-385-h/) Boviet Solar Technology Co Ltd | 385.0 W | -5.0 W | 48.5 V | 19.85% | 93.1% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for PANASONIC CORPORATION OF NORTH AMERICA EVPV390H?

Evaluate PANASONIC CORPORATION OF NORTH AMERICA EVPV390H (390.0 W STC, 48.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), PANASONIC CORPORATION OF NORTH AMERICA EVPV390H reaches 53.61 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 405 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (405 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of PANASONIC CORPORATION OF NORTH AMERICA EVPV390H carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### PANASONIC CORPORATION OF NORTH AMERICA EVPV390H 8 kW Residential Fit

Needs 21 modules (405 sq ft) with a 20 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS3U-390MS.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 372.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PANASONIC CORPORATION OF NORTH AMERICA EVPV390H by PANASONIC CORPORATION OF NORTH AMERICA grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for PANASONIC CORPORATION OF NORTH AMERICA EVPV390H?

Multiplying PANASONIC CORPORATION OF NORTH AMERICA EVPV390H's 10.19 A short-circuit current by 1.56 equals 15.9 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

### Can PANASONIC CORPORATION OF NORTH AMERICA EVPV390H pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 52.5 V cold Voc at 14 F and handles 10.19 A Isc; string inverters cap PANASONIC CORPORATION OF NORTH AMERICA EVPV390H at 11 panels on 600 V.

### Is PANASONIC CORPORATION OF NORTH AMERICA EVPV390H eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of PANASONIC CORPORATION OF NORTH AMERICA EVPV390H rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.

## Related Pages

Compare PANASONIC CORPORATION OF NORTH AMERICA equipment, CSI Solar Co Ltd CS3U-390MS specs, utility payback rates, and NEC string calculators alongside PANASONIC CORPORATION OF NORTH AMERICA EVPV390H.

[All PANASONIC CORPORATION OF NORTH AMERICA Certified Solar Models](https://epri-peac.com/solar-equipment/brands/panasonic-corporation-of-north-america/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From PANASONIC CORPORATION OF NORTH AMERICA

- [All PANASONIC CORPORATION OF NORTH AMERICA Specs](https://epri-peac.com/solar-equipment/brands/panasonic-corporation-of-north-america/)
- [PANASONIC CORPORATION OF NORTH AMERICA EVPV430HK2](https://epri-peac.com/solar-equipment/modules/panasonic-corporation-of-north-america/panasonic-corporation-of-north-america-evpv430hk2/)
- [PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2](https://epri-peac.com/solar-equipment/modules/panasonic-corporation-of-north-america/panasonic-corporation-of-north-america-evpv420hk2/)
- [PANASONIC CORPORATION OF NORTH AMERICA EVPV410H](https://epri-peac.com/solar-equipment/modules/panasonic-corporation-of-north-america/panasonic-corporation-of-north-america-evpv410h/)
- [PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK](https://epri-peac.com/solar-equipment/modules/panasonic-corporation-of-north-america/panasonic-corporation-of-north-america-evpv410hk/)
- [PANASONIC CORPORATION OF NORTH AMERICA EVPV390HK](https://epri-peac.com/solar-equipment/modules/panasonic-corporation-of-north-america/panasonic-corporation-of-north-america-evpv390hk/)