Over Easy Solar OES64-EU is a 64.0 W STC (60.9 W PTC) Mono-c-Si solar module ranking #21,650 of 21,677 CEC listings (below all-CEC median; higher than 0.1% of peers). It delivers 17.78% efficiency, 9.75 V Voc at 25 C, and 10.56 V cold Voc at -10 C (56 panels max per 600 V string).

- **STC Wattage** : 64.0 W

- **PTC Wattage** : 60.9 W

- **Voc @ 25C** : 9.75 V

- **Efficiency** : 17.78%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Over Easy Solar OES64-EU Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Over Easy Solar OES64-EU (Mono-c-Si) residential solar systems.

Over Easy Solar OES64-EU delivers 177.8 W/m2 (2.13 percentage points below 19.91% CEC median) and strong 95.2% PTC-to-STC heat retention (#399 of 21,677), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 125 panels (484 sq ft). At -4 F (-20 C), string voltage climbs to 10.79 V per unit, capping 600 V circuits at 55 panels. Compare specs directly with HALEE Inc HST-61-E-FP (61.0 W).

## Where Does Over Easy Solar OES64-EU Fall Across Listed CEC Models?

Comparison of Over Easy Solar OES64-EU (64.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define Over Easy Solar OES64-EU?

Relative ranking of Over Easy Solar OES64-EU across nameplate watts, 95.2% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for Over Easy Solar OES64-EU?

Summary of Over Easy Solar OES64-EU output rank, 8 kW array size (125 panels), efficiency rating, and 600 V string limit.

Rank #21,650 / 21,677

### 64.0 W STC · Higher Than 0.1%

64.0 W STC (-321.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #15,390

### 17.78% Aperture Efficiency

Power density 177.8 W/m2 (2.13 percentage points below 19.91% CEC median). PTC/STC ratio: 95.2% (rank #399).

NEC 690.7 Limit

### 56 Panels Max @ -10 C (600 V)

Cold Voc reaches 10.56 V at -10 C (591.4 V string) and 10.79 V at -20 C (55 max).

 8 kW Reference Array

### 125 Panels = 8,000 W STC

Occupies 45.0 m2 (484 sq ft) producing 7,612 W PTC; NEC 690.8 OCPD floor is 12.54 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 9.75 * (1 + (-0.237/100) * (-10 - 25)) = 10.56 V | OCPD = 1.56 * 8.04 = 12.54 A

Inputs from CEC Modules.csv for Over Easy Solar OES64-EU: Voc=9.75 V, beta_Voc=-0.237%/C, Isc=8.04 A, STC=64.0 W, Area=0.36 m2.

**Result:** 56 panels max on 600 V (591.4 V); 125 panels for 8 kW (484 sq ft).

## What Are the Published CEC Specifications for Over Easy Solar OES64-EU?

Complete CEC test sheet for Over Easy Solar OES64-EU including Isc (8.04 A), Voc (9.75 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Over Easy Solar OES64-EU.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 64.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 60.9 W (95.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 9.75 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.04 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 8.24 V / 7.74 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.237 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 17.78% (0.36 m2) | Array roof footprint density |
| **Cell Count & Technology** | 13 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Over Easy Solar OES64-EU Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Over Easy Solar OES64-EU.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 94 | 6.02 kW | 364 sq ft | $1,507 | $2,548 |
| **8 kW Class** | 125 | 8.0 kW | 484 sq ft | $2,002 | $3,386 |
| **10 kW Class** | 157 | 10.05 kW | 608 sq ft | $2,515 | $4,253 |

## How Many Over Easy Solar OES64-EU Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Over Easy Solar OES64-EU (9.75 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=9.75V and beta_Voc=-0.237%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 10.79 V | 55 panels | 593.4 V | 92 panels |
| **-10 C (14 F)** | 10.56 V | 56 panels | 591.4 V | 94 panels |
| **0 C (32 F)** | 10.33 V | 58 panels | 599.1 V | 96 panels |
| **25 C (77 F STC)** | 9.75 V | 61 panels | 594.8 V | 102 panels |

## Which Cross-Brand Solar Modules Compare Closest to Over Easy Solar OES64-EU?

Four comparable CEC modules such as HALEE Inc HST-61-E-FP (61.0 W) for side-by-side solar quote checks. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**HALEE Inc HST-61-E-FP**](https://epri-peac.com/solar-equipment/modules/halee-inc/halee-inc-hst-61-e-fp/) HALEE Inc | 61.0 W | -3.0 W | 9.5 V | 14.88% | 85.6% |
| [**CertainTeed Apollo II - 67**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-apollo-ii-67/) CertainTeed | 67.0 W | +3.0 W | 9.35 V | 15.95% | 90.9% |
| [**CertainTeed Apollo Tile II - 67**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-apollo-tile-ii-67/) CertainTeed | 67.0 W | +3.0 W | 9.35 V | 15.95% | 91.2% |
| [**CertainTeed Solstice Shingle 68W-01**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-solstice-shingle-68w-01/) CertainTeed | 68.0 W | +4.0 W | 9.37 V | 12.83% | 89.4% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Over Easy Solar OES64-EU?

Evaluate Over Easy Solar OES64-EU (64.0 W STC, 9.75 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Over Easy Solar OES64-EU reaches 10.79 V per panel—exceeding 55 panels in series voids 600 V inverter warranties.
- Footprint constraint: 125 panels for an 8 kW build require 484 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 125 panels (484 sq ft).
- 2026 tax credit baseline: cash residential installs of Over Easy Solar OES64-EU carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Over Easy Solar OES64-EU 8 kW Residential Fit

Needs 125 modules (484 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 56 panels (-10 C) or 55 panels (-20 C), or compare HALEE Inc HST-61-E-FP.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 60.9 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Over Easy Solar OES64-EU by Over Easy Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Over Easy Solar OES64-EU panels fit on a 600 V winter solar string?

At -10 C (14 F), Over Easy Solar OES64-EU cold Voc rises from 9.75 V to 10.56 V (beta_Voc -0.237%/C), capping a 600 V string at 56 panels (591.4 V).

### How much roof area does an 8 kW array of Over Easy Solar OES64-EU need?

An 8 kW DC system uses 125 Over Easy Solar OES64-EU modules (8,000 W STC / 7,612 W PTC), covering roughly 484 sq ft and saving ~$2,002/yr at 18.54 c/kWh.

### How does Over Easy Solar OES64-EU compare against HALEE Inc HST-61-E-FP?

Over Easy Solar OES64-EU outputs 64.0 W STC (9.75 V Voc, rank #21,650 of 21,677), while HALEE Inc HST-61-E-FP delivers 61.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Over Easy Solar equipment, HALEE Inc HST-61-E-FP specs, utility payback rates, and NEC string calculators alongside Over Easy Solar OES64-EU.

[All Over Easy Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/over-easy-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Over Easy Solar

- [All Over Easy Solar Specs](https://epri-peac.com/solar-equipment/brands/over-easy-solar/)