title: "Optivolt Labs Inc OPT10M450W Specs (450.0W, 39.75V Voc)"
url: https://epri-peac.com/solar-equipment/modules/optivolt-labs-inc/optivolt-labs-inc-opt10m450w/
description: "CEC datasheet for Optivolt Labs Inc OPT10M450W: 450.0W STC, 39.75V Voc, 18-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Optivolt Labs Inc OPT10M450W — CEC Solar Module Specifications

Manufacturer: [**Optivolt Labs Inc**](https://epri-peac.com/solar-equipment/brands/optivolt-labs-inc/) Registry: **CEC Verified Engineering Specification**

Optivolt Labs Inc OPT10M450W is a 450.0 W STC (413.8 W PTC) Mono-c-Si solar module ranking #5,679 of 21,677 CEC listings (top 27.8%; higher than 72.2% of peers). It delivers 23.2% efficiency, 39.75 V Voc at 25 C, and 43.65 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 450.0 W

- **PTC Wattage** : 413.8 W

- **Voc @ 25C** : 39.75 V

- **Efficiency** : 23.2%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Optivolt Labs Inc OPT10M450W Compare Against Peer CEC Listings?

How Optivolt Labs Inc Optivolt Labs Inc OPT10M450W handles rooftop heat (413.8 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Optivolt Labs Inc OPT10M450W exhibits 14.14 A short-circuit current, requiring a 22.06 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #5,679 of 21,677 (40.0 W above the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 34.9 m2 for an 8 kW system (23 panels for 10 kW). Lower 39.75 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters.

## Where Does Optivolt Labs Inc OPT10M450W Fall Across Listed CEC Models?

Where Optivolt Labs Inc OPT10M450W (450.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Optivolt Labs Inc OPT10M450W?

Percentile placement of Optivolt Labs Inc OPT10M450W across power density (232.0 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Optivolt Labs Inc OPT10M450W?

Four critical engineering numbers homeowners and solar installers check first when reviewing Optivolt Labs Inc OPT10M450W specifications. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Rank #5,679 / 21,677

### Top 27.8% STC Output

450.0 W STC (+65.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #871

### 23.2% Aperture Efficiency

Power density 232.0 W/m2 (3.29 percentage points above 19.91% CEC median). PTC/STC ratio: 92.0% (rank #14,141).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.65 V at -10 C (567.4 V string) and 44.76 V at -20 C (13 max).

 8 kW Reference Array

### 18 Panels = 8,100 W STC

Occupies 34.9 m2 (376 sq ft) producing 7,448 W PTC; NEC 690.8 OCPD floor is 22.06 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.75 * (1 + (-0.28/100) * (-10 - 25)) = 43.65 V | OCPD = 1.56 * 14.14 = 22.06 A

Inputs from CEC Modules.csv for Optivolt Labs Inc OPT10M450W: Voc=39.75 V, beta_Voc=-0.28%/C, Isc=14.14 A, STC=450.0 W, Area=1.94 m2.

**Result:** 13 panels max on 600 V (567.4 V); 18 panels for 8 kW (376 sq ft).

## What Are the Published CEC Specifications for Optivolt Labs Inc OPT10M450W?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Optivolt Labs Inc OPT10M450W.

Official California Energy Commission (NREL SAM) test parameters for Optivolt Labs Inc OPT10M450W.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 450.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 413.8 W (92.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 39.75 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 14.14 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 33.51 V / 13.44 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.28 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 23.2% (1.94 m2) | Array roof footprint density |
| **Cell Count & Technology** | 54 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Optivolt Labs Inc OPT10M450W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Optivolt Labs Inc OPT10M450W (450.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 14 | 6.3 kW | 292 sq ft | $1,577 | $2,666 |
| **8 kW Class** | 18 | 8.1 kW | 376 sq ft | $2,027 | $3,428 |
| **10 kW Class** | 23 | 10.35 kW | 480 sq ft | $2,591 | $4,380 |

## How Many Optivolt Labs Inc OPT10M450W Modules Fit in a Cold-Weather String?

Maximum series module counts for Optivolt Labs Inc OPT10M450W from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=39.75V and beta_Voc=-0.28%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 44.76 V | 13 panels | 581.9 V | 22 panels |
| **-10 C (14 F)** | 43.65 V | 13 panels | 567.4 V | 22 panels |
| **0 C (32 F)** | 42.53 V | 14 panels | 595.4 V | 23 panels |
| **25 C (77 F STC)** | 39.75 V | 15 panels | 596.2 V | 25 panels |

## Which Cross-Brand Solar Modules Compare Closest to Optivolt Labs Inc OPT10M450W?

Alternative CEC solar modules from competing brands near Optivolt Labs Inc OPT10M450W (450.0 W), including Auxin Solar AXN10M450B.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Auxin Solar AXN10M450B**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m450b/) Auxin Solar | 450.0 W | Tie (0 W) | 39.75 V | 23.2% | 91.4% |
| [**HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T450NF(BK)**](https://epri-peac.com/solar-equipment/modules/hd-hyundai-energy-solutions-co-ltd/hd-hyundai-energy-solutions-co-ltd-hin-t450nf-bk/) HD HYUNDAI ENERGY SOLUTIONS CO LTD | 450.0 W | Tie (0 W) | 39.2 V | 23.2% | 94.9% |
| [**AXITEC AC-450TGB/108BB**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-450tgb-108bb/) AXITEC | 450.0 W | Tie (0 W) | 38.8 V | 23.68% | 95.1% |
| [**ELITE Solar ET-N754TBH455GB**](https://epri-peac.com/solar-equipment/modules/elite-solar/elite-solar-et-n754tbh455gb/) ELITE Solar | 455.0 W | +5.0 W | 39.86 V | 23.33% | 95.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Optivolt Labs Inc OPT10M450W?

Evaluate Optivolt Labs Inc OPT10M450W (450.0 W STC, 39.75 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Optivolt Labs Inc OPT10M450W reaches 44.76 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 376 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (376 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Optivolt Labs Inc OPT10M450W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Optivolt Labs Inc OPT10M450W 8 kW Residential Fit

Needs 18 modules (376 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Auxin Solar AXN10M450B.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 413.8 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Optivolt Labs Inc OPT10M450W by Optivolt Labs Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Optivolt Labs Inc OPT10M450W PTC wattage (413.8 W) lower than STC (450.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 413.8 W PTC (92.0% retention) across Optivolt Labs Inc OPT10M450W's 1.94 m2 aperture.

### Who should skip Optivolt Labs Inc OPT10M450W on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 18 Optivolt Labs Inc OPT10M450W panels (376 sq ft) leave unusable roof gaps vs. Auxin Solar AXN10M450B.

### What is the 1,000 V commercial string limit for Optivolt Labs Inc OPT10M450W?

On 1,000 V commercial inverters at -10 C (43.65 V cold Voc), Optivolt Labs Inc OPT10M450W fits up to 22 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Optivolt Labs Inc OPT10M450W.

## Related Pages

Compare Optivolt Labs Inc equipment, Auxin Solar AXN10M450B specs, utility payback rates, and NEC string calculators alongside Optivolt Labs Inc OPT10M450W.

[All Optivolt Labs Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/optivolt-labs-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Optivolt Labs Inc

- [All Optivolt Labs Inc Specs](https://epri-peac.com/solar-equipment/brands/optivolt-labs-inc/)
- [Optivolt Labs Inc OPT10M450B](https://epri-peac.com/solar-equipment/modules/optivolt-labs-inc/optivolt-labs-inc-opt10m450b/)
- [Optivolt Labs Inc OPT10M440B](https://epri-peac.com/solar-equipment/modules/optivolt-labs-inc/optivolt-labs-inc-opt10m440b/)
- [Optivolt Labs Inc OPT10M440W](https://epri-peac.com/solar-equipment/modules/optivolt-labs-inc/optivolt-labs-inc-opt10m440w/)