# ONYX SOLAR ENERGY SL ONYX G/G M06666 — CEC Solar Module Specifications

Manufacturer: [**ONYX SOLAR ENERGY SL**](https://epri-peac.com/solar-equipment/brands/onyx-solar-energy-sl/) Registry: **CEC Verified Engineering Specification**

ONYX SOLAR ENERGY SL ONYX G/G M06666 is a 291.0 W STC (256.6 W PTC) Mono-c-Si solar module ranking #17,252 of 21,677 CEC listings (below all-CEC median; higher than 20.4% of peers). It delivers 14.62% efficiency, 42.0 V Voc at 25 C, and 46.85 V cold Voc at -10 C (12 panels max per 600 V string).

- **STC Wattage** : 291.0 W

- **PTC Wattage** : 256.6 W

- **Voc @ 25C** : 42.0 V

- **Efficiency** : 14.62%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does ONYX SOLAR ENERGY SL ONYX G/G M06666 Compare Against Peer CEC Listings?

Engineering position of ONYX SOLAR ENERGY SL ONYX G/G M06666 (291.0 W STC) vs. Gintung Energy ASEC-285G6M6B across 5,889 CEC Mono-c-Si solar modules.

Built with 66 Mono-c-Si cells, ONYX SOLAR ENERGY SL ONYX G/G M06666 pairs typical 88.2% PTC-to-STC thermal output (256.6 W real-world rating) with 42.0 V nominal Voc. An 8 kW residential build (8,148 W DC, 7,185 W PTC) saves ~$2,040/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Gintung Energy ASEC-285G6M6B offers a 285.0 W alternative.

## Where Does ONYX SOLAR ENERGY SL ONYX G/G M06666 Fall Across Listed CEC Models?

Plots ONYX SOLAR ENERGY SL ONYX G/G M06666 at 291.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define ONYX SOLAR ENERGY SL ONYX G/G M06666?

Benchmarks ONYX SOLAR ENERGY SL ONYX G/G M06666 on STC wattage, thermal PTC/STC retention, and 14.62 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for ONYX SOLAR ENERGY SL ONYX G/G M06666?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for ONYX SOLAR ENERGY SL ONYX G/G M06666 by ONYX SOLAR ENERGY SL.

Rank #17,252 / 21,677

### 291.0 W STC · Higher Than 20.4%

291.0 W STC (-94.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #20,269

### 14.62% Aperture Efficiency

Power density 146.2 W/m2 (5.29 percentage points below 19.91% CEC median). PTC/STC ratio: 88.2% (rank #21,309).

NEC 690.7 Limit

### 12 Panels Max @ -10 C (600 V)

Cold Voc reaches 46.85 V at -10 C (562.2 V string) and 48.24 V at -20 C (12 max).

 8 kW Reference Array

### 28 Panels = 8,148 W STC

Occupies 55.7 m2 (600 sq ft) producing 7,185 W PTC; NEC 690.8 OCPD floor is 13.93 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 42.0 * (1 + (-0.33/100) * (-10 - 25)) = 46.85 V | OCPD = 1.56 * 8.93 = 13.93 A

Inputs from CEC Modules.csv for ONYX SOLAR ENERGY SL ONYX G/G M06666: Voc=42.0 V, beta_Voc=-0.33%/C, Isc=8.93 A, STC=291.0 W, Area=1.99 m2.

**Result:** 12 panels max on 600 V (562.2 V); 28 panels for 8 kW (600 sq ft).

## What Are the Published CEC Specifications for ONYX SOLAR ENERGY SL ONYX G/G M06666?

Laboratory test ratings recorded for ONYX SOLAR ENERGY SL ONYX G/G M06666 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for ONYX SOLAR ENERGY SL ONYX G/G M06666.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 291.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 256.6 W (88.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 42.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.93 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 35.0 V / 8.39 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.33 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 14.62% (1.99 m2) | Array roof footprint density |
| **Cell Count & Technology** | 66 cells (Mono-c-Si) | Monofacial backsheet |

## How Many ONYX SOLAR ENERGY SL ONYX G/G M06666 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (600 sq ft at 8 kW), and estimated Year-1 electric bill offset for ONYX SOLAR ENERGY SL ONYX G/G M06666.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 21 | 6.11 kW | 450 sq ft | $1,529 | $2,586 |
| **8 kW Class** | 28 | 8.15 kW | 600 sq ft | $2,040 | $3,449 |
| **10 kW Class** | 35 | 10.19 kW | 750 sq ft | $2,550 | $4,313 |

## How Many ONYX SOLAR ENERGY SL ONYX G/G M06666 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for ONYX SOLAR ENERGY SL ONYX G/G M06666 (beta_Voc -0.33%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=42.0V and beta_Voc=-0.33%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 48.24 V | 12 panels | 578.9 V | 20 panels |
| **-10 C (14 F)** | 46.85 V | 12 panels | 562.2 V | 21 panels |
| **0 C (32 F)** | 45.47 V | 13 panels | 591.1 V | 21 panels |
| **25 C (77 F STC)** | 42.0 V | 14 panels | 588.0 V | 23 panels |

## Which Cross-Brand Solar Modules Compare Closest to ONYX SOLAR ENERGY SL ONYX G/G M06666?

Closest cross-brand CEC competitors to ONYX SOLAR ENERGY SL ONYX G/G M06666 matched near 291.0 W STC and 42.0 V Voc, led by Gintung Energy ASEC-285G6M6B.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Gintung Energy ASEC-285G6M6B**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-285g6m6b/) Gintung Energy | 285.0 W | -6.0 W | 41.75 V | 16.07% | 88.1% |
| [**Gintung Energy GTEC-285G6M6B**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-285g6m6b/) Gintung Energy | 285.0 W | -6.0 W | 41.75 V | 16.07% | 88.1% |
| [**Gintung Energy ASEC-285G6S6B**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-285g6s6b/) Gintung Energy | 285.0 W | -6.0 W | 41.29 V | 16.07% | 87.7% |
| [**Gintung Energy GTEC-285G6S6B**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-285g6s6b/) Gintung Energy | 285.0 W | -6.0 W | 41.29 V | 16.07% | 87.7% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for ONYX SOLAR ENERGY SL ONYX G/G M06666?

Evaluate ONYX SOLAR ENERGY SL ONYX G/G M06666 (291.0 W STC, 42.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), ONYX SOLAR ENERGY SL ONYX G/G M06666 reaches 48.24 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 28 panels for an 8 kW build require 600 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (600 sq ft).
- 2026 tax credit baseline: cash residential installs of ONYX SOLAR ENERGY SL ONYX G/G M06666 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### ONYX SOLAR ENERGY SL ONYX G/G M06666 8 kW Residential Fit

Needs 28 modules (600 sq ft) with a 15 A string OCPD, offsetting ~$2,040/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Gintung Energy ASEC-285G6M6B.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 256.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for ONYX SOLAR ENERGY SL ONYX G/G M06666 by ONYX SOLAR ENERGY SL grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for ONYX SOLAR ENERGY SL ONYX G/G M06666?

Multiplying ONYX SOLAR ENERGY SL ONYX G/G M06666's 8.93 A short-circuit current by 1.56 equals 13.93 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can ONYX SOLAR ENERGY SL ONYX G/G M06666 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 46.85 V cold Voc at 14 F and handles 8.93 A Isc; string inverters cap ONYX SOLAR ENERGY SL ONYX G/G M06666 at 12 panels on 600 V.

### Is ONYX SOLAR ENERGY SL ONYX G/G M06666 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of ONYX SOLAR ENERGY SL ONYX G/G M06666 rely on utility bill offset (~$2,040/yr at 8 kW) rather than 25D.

## Related Pages

Compare ONYX SOLAR ENERGY SL equipment, Gintung Energy ASEC-285G6M6B specs, utility payback rates, and NEC string calculators alongside ONYX SOLAR ENERGY SL ONYX G/G M06666.

[All ONYX SOLAR ENERGY SL Certified Solar Models](https://epri-peac.com/solar-equipment/brands/onyx-solar-energy-sl/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From ONYX SOLAR ENERGY SL

- [All ONYX SOLAR ENERGY SL Specs](https://epri-peac.com/solar-equipment/brands/onyx-solar-energy-sl/)