title: "Mitsubishi Electric PV-UJ230GA6-D Specs (230.0W, 36.6V Voc)"
url: https://epri-peac.com/solar-equipment/modules/mitsubishi-electric/mitsubishi-electric-pv-uj230ga6-d/
description: "CEC datasheet for Mitsubishi Electric PV-UJ230GA6-D: 230.0W STC, 36.6V Voc, 35-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Mitsubishi Electric PV-UJ230GA6-D — CEC Solar Module Specifications

Manufacturer: [**Mitsubishi Electric**](https://epri-peac.com/solar-equipment/brands/mitsubishi-electric/) Registry: **CEC Verified Engineering Specification**

Mitsubishi Electric PV-UJ230GA6-D is a 230.0 W STC (207.8 W PTC) Multi-c-Si solar module ranking #20,522 of 21,677 CEC listings (below all-CEC median; higher than 4.7% of peers). It delivers 13.96% efficiency, 36.6 V Voc at 25 C, and 40.7 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 230.0 W

- **PTC Wattage** : 207.8 W

- **Voc @ 25C** : 36.6 V

- **Efficiency** : 13.96%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Mitsubishi Electric PV-UJ230GA6-D Compare Against Peer CEC Listings?

Engineering position of Mitsubishi Electric PV-UJ230GA6-D (230.0 W STC) vs. Gintung Energy ASEC-230G6S across 1,407 CEC Multi-c-Si solar modules.

Built with 60 Multi-c-Si cells, Mitsubishi Electric PV-UJ230GA6-D pairs typical 90.3% PTC-to-STC thermal output (207.8 W real-world rating) with 36.6 V nominal Voc. An 8 kW residential build (8,050 W DC, 7,273 W PTC) saves ~$2,015/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Gintung Energy ASEC-230G6S offers a 230.0 W alternative.

## Where Does Mitsubishi Electric PV-UJ230GA6-D Fall Across Listed CEC Models?

Plots Mitsubishi Electric PV-UJ230GA6-D at 230.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define Mitsubishi Electric PV-UJ230GA6-D?

Benchmarks Mitsubishi Electric PV-UJ230GA6-D on STC wattage, thermal PTC/STC retention, and 13.96 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for Mitsubishi Electric PV-UJ230GA6-D?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Mitsubishi Electric PV-UJ230GA6-D by Mitsubishi Electric.

Rank #20,522 / 21,677

### 230.0 W STC · Higher Than 4.7%

230.0 W STC (-155.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,928

### 13.96% Aperture Efficiency

Power density 139.6 W/m2 (5.95 percentage points below 19.91% CEC median). PTC/STC ratio: 90.3% (rank #18,305).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.7 V at -10 C (569.8 V string) and 41.87 V at -20 C (14 max).

 8 kW Reference Array

### 35 Panels = 8,050 W STC

Occupies 57.7 m2 (621 sq ft) producing 7,273 W PTC; NEC 690.8 OCPD floor is 13.09 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.6 * (1 + (-0.32/100) * (-10 - 25)) = 40.7 V | OCPD = 1.56 * 8.39 = 13.09 A

Inputs from CEC Modules.csv for Mitsubishi Electric PV-UJ230GA6-D: Voc=36.6 V, beta_Voc=-0.32%/C, Isc=8.39 A, STC=230.0 W, Area=1.648 m2.

**Result:** 14 panels max on 600 V (569.8 V); 35 panels for 8 kW (621 sq ft).

## What Are the Published CEC Specifications for Mitsubishi Electric PV-UJ230GA6-D?

Laboratory test ratings recorded for Mitsubishi Electric PV-UJ230GA6-D (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Mitsubishi Electric PV-UJ230GA6-D.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 230.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 207.8 W (90.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 36.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.39 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 30.2 V / 7.62 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.32 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 13.96% (1.648 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Mitsubishi Electric PV-UJ230GA6-D Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (621 sq ft at 8 kW), and estimated Year-1 electric bill offset for Mitsubishi Electric PV-UJ230GA6-D.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 27 | 6.21 kW | 479 sq ft | $1,554 | $2,628 |
| **8 kW Class** | 35 | 8.05 kW | 621 sq ft | $2,015 | $3,407 |
| **10 kW Class** | 44 | 10.12 kW | 781 sq ft | $2,533 | $4,283 |

## Which Sibling Wattage & Trim Variants Belong to This Mitsubishi Electric Series?

Sibling wattage bins and frame colors grouped with Mitsubishi Electric PV-UJ230GA6-D under Mitsubishi Electric to prevent duplicate spec pages.

Sibling CEC listings grouped into the Mitsubishi Electric PV-UJ230GA6-D wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Mitsubishi Electric PV-UJ225GA6-D** | 225.0 W | 203.2 W | 36.4 V | 30.0 V | 13.65% |
| **Mitsubishi Electric PV-UJ230GA6-D** | 230.0 W | 207.8 W | 36.6 V | 30.2 V | 13.96% |
| **Mitsubishi Electric PV-UJ235GA6-D** | 235.0 W | 212.4 W | 36.8 V | 30.5 V | 14.26% |

## How Many Mitsubishi Electric PV-UJ230GA6-D Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Mitsubishi Electric PV-UJ230GA6-D (beta_Voc -0.32%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=36.6V and beta_Voc=-0.32%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 41.87 V | 14 panels | 586.2 V | 23 panels |
| **-10 C (14 F)** | 40.7 V | 14 panels | 569.8 V | 24 panels |
| **0 C (32 F)** | 39.53 V | 15 panels | 593.0 V | 25 panels |
| **25 C (77 F STC)** | 36.6 V | 16 panels | 585.6 V | 27 panels |

## Which Cross-Brand Solar Modules Compare Closest to Mitsubishi Electric PV-UJ230GA6-D?

Closest cross-brand CEC competitors to Mitsubishi Electric PV-UJ230GA6-D matched near 230.0 W STC and 36.6 V Voc, led by Gintung Energy ASEC-230G6S.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Gintung Energy ASEC-230G6S**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-230g6s/) Gintung Energy | 230.0 W | Tie (0 W) | 36.75 V | 14.28% | 89.7% |
| [**Grape Solar GS-P-230-CS**](https://epri-peac.com/solar-equipment/modules/grape-solar/grape-solar-gs-p-230-cs/) Grape Solar | 230.0 W | Tie (0 W) | 36.8 V | 14.3% | 91.7% |
| [**Gintung Energy ASEC-230G6M**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-230g6m/) Gintung Energy | 230.0 W | Tie (0 W) | 36.87 V | 14.28% | 89.4% |
| [**Anji Dasol Solar Energy Science & Technology DS-A4-230**](https://epri-peac.com/solar-equipment/modules/anji-dasol-solar-energy-science-technology/anji-dasol-solar-energy-science-technology-ds-a4-230/) Anji Dasol Solar Energy Science & Technology | 230.0 W | Tie (0 W) | 36.9 V | 13.97% | 87.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Mitsubishi Electric PV-UJ230GA6-D?

Evaluate Mitsubishi Electric PV-UJ230GA6-D (230.0 W STC, 36.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Mitsubishi Electric PV-UJ230GA6-D reaches 41.87 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 35 panels for an 8 kW build require 621 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (621 sq ft).
- 2026 tax credit baseline: cash residential installs of Mitsubishi Electric PV-UJ230GA6-D carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Mitsubishi Electric PV-UJ230GA6-D 8 kW Residential Fit

Needs 35 modules (621 sq ft) with a 15 A string OCPD, offsetting ~$2,015/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Gintung Energy ASEC-230G6S.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 207.8 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Mitsubishi Electric PV-UJ230GA6-D by Mitsubishi Electric grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Mitsubishi Electric PV-UJ230GA6-D?

Multiplying Mitsubishi Electric PV-UJ230GA6-D's 8.39 A short-circuit current by 1.56 equals 13.09 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can Mitsubishi Electric PV-UJ230GA6-D pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 40.7 V cold Voc at 14 F and handles 8.39 A Isc; string inverters cap Mitsubishi Electric PV-UJ230GA6-D at 14 panels on 600 V.

### Is Mitsubishi Electric PV-UJ230GA6-D eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Mitsubishi Electric PV-UJ230GA6-D rely on utility bill offset (~$2,015/yr at 8 kW) rather than 25D.

## Related Pages

Compare Mitsubishi Electric equipment, Gintung Energy ASEC-230G6S specs, utility payback rates, and NEC string calculators alongside Mitsubishi Electric PV-UJ230GA6-D.

[All Mitsubishi Electric Certified Solar Models](https://epri-peac.com/solar-equipment/brands/mitsubishi-electric/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Mitsubishi Electric

- [All Mitsubishi Electric Specs](https://epri-peac.com/solar-equipment/brands/mitsubishi-electric/)
- [Mitsubishi Electric PV-MJE280FB](https://epri-peac.com/solar-equipment/modules/mitsubishi-electric/mitsubishi-electric-pv-mje280fb/)
- [Mitsubishi Electric PV-MJE280FB-B](https://epri-peac.com/solar-equipment/modules/mitsubishi-electric/mitsubishi-electric-pv-mje280fb-b/)