Mitsubishi Electric PV-UD170MF5 is a 170.0 W STC (150.9 W PTC) Multi-c-Si solar module ranking #21,323 of 21,677 CEC listings (below all-CEC median; higher than 1.5% of peers). It delivers 12.29% efficiency, 29.9 V Voc at 25 C, and 33.71 V cold Voc at -10 C (17 panels max per 600 V string).

- **STC Wattage** : 170.0 W

- **PTC Wattage** : 150.9 W

- **Voc @ 25C** : 29.9 V

- **Efficiency** : 12.29%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Mitsubishi Electric PV-UD170MF5 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Mitsubishi Electric PV-UD170MF5 (Multi-c-Si) residential solar systems.

Homeowners evaluating Mitsubishi Electric PV-UD170MF5 need 36 panels for 6 kW or 48 panels (715 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 48 panels (715 sq ft). Under NEC 690.7(A), beta_Voc (-0.364%/C) pushes open-circuit voltage to 33.71 V at 14 F and 34.8 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does Mitsubishi Electric PV-UD170MF5 Fall Across Listed CEC Models?

Comparison of Mitsubishi Electric PV-UD170MF5 (170.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

## What Dataset Percentiles Define Mitsubishi Electric PV-UD170MF5?

Relative ranking of Mitsubishi Electric PV-UD170MF5 across nameplate watts, 88.8% PTC thermal ratio, and module aperture efficiency. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

## What Do the Dataset Ranks Show for Mitsubishi Electric PV-UD170MF5?

Summary of Mitsubishi Electric PV-UD170MF5 output rank, 8 kW array size (48 panels), efficiency rating, and 600 V string limit.

Rank #21,323 / 21,677

### 170.0 W STC · Higher Than 1.5%

170.0 W STC (-215.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,549

### 12.29% Aperture Efficiency

Power density 122.9 W/m2 (7.62 percentage points below 19.91% CEC median). PTC/STC ratio: 88.8% (rank #20,967).

NEC 690.7 Limit

### 17 Panels Max @ -10 C (600 V)

Cold Voc reaches 33.71 V at -10 C (573.1 V string) and 34.8 V at -20 C (17 max).

 8 kW Reference Array

### 48 Panels = 8,160 W STC

Occupies 66.4 m2 (715 sq ft) producing 7,243 W PTC; NEC 690.8 OCPD floor is 12.21 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 29.9 * (1 + (-0.364/100) * (-10 - 25)) = 33.71 V | OCPD = 1.56 * 7.83 = 12.21 A

Inputs from CEC Modules.csv for Mitsubishi Electric PV-UD170MF5: Voc=29.9 V, beta_Voc=-0.364%/C, Isc=7.83 A, STC=170.0 W, Area=1.383 m2.

**Result:** 17 panels max on 600 V (573.1 V); 48 panels for 8 kW (715 sq ft).

## What Are the Published CEC Specifications for Mitsubishi Electric PV-UD170MF5?

Complete CEC test sheet for Mitsubishi Electric PV-UD170MF5 including Isc (7.83 A), Voc (29.9 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Mitsubishi Electric PV-UD170MF5.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 170.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 150.9 W (88.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 29.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 7.83 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 23.7 V / 7.19 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.364 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 12.29% (1.383 m2) | Array roof footprint density |
| **Cell Count & Technology** | 50 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Mitsubishi Electric PV-UD170MF5 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Mitsubishi Electric PV-UD170MF5.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 36 | 6.12 kW | 536 sq ft | $1,532 | $2,590 |
| **8 kW Class** | 48 | 8.16 kW | 715 sq ft | $2,042 | $3,454 |
| **10 kW Class** | 59 | 10.03 kW | 878 sq ft | $2,510 | $4,245 |

## How Many Mitsubishi Electric PV-UD170MF5 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Mitsubishi Electric PV-UD170MF5 (29.9 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=29.9V and beta_Voc=-0.364%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 34.8 V | 17 panels | 591.6 V | 28 panels |
| **-10 C (14 F)** | 33.71 V | 17 panels | 573.1 V | 29 panels |
| **0 C (32 F)** | 32.62 V | 18 panels | 587.2 V | 30 panels |
| **25 C (77 F STC)** | 29.9 V | 20 panels | 598.0 V | 33 panels |

## Which Cross-Brand Solar Modules Compare Closest to Mitsubishi Electric PV-UD170MF5?

Four comparable CEC modules such as Lightway Green New Energy LW170(23)P1310x990 (170.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Lightway Green New Energy LW170(23)P1310x990**](https://epri-peac.com/solar-equipment/modules/lightway-green-new-energy/lightway-green-new-energy-lw170-23-p1310x990/) Lightway Green New Energy | 170.0 W | Tie (0 W) | 29.5 V | 13.25% | 89.4% |
| [**Yingli Energy (China) YL170P-23b**](https://epri-peac.com/solar-equipment/modules/yingli-energy-china/yingli-energy-china-yl170p-23b/) Yingli Energy (China) | 170.0 W | Tie (0 W) | 29.0 V | 13.24% | 90.7% |
| [**Lightway Green New Energy LW175(23)P1310x990**](https://epri-peac.com/solar-equipment/modules/lightway-green-new-energy/lightway-green-new-energy-lw175-23-p1310x990/) Lightway Green New Energy | 175.0 W | +5.0 W | 29.5 V | 13.63% | 89.4% |
| [**Lightway Green New Energy LW165(23)P1310x990**](https://epri-peac.com/solar-equipment/modules/lightway-green-new-energy/lightway-green-new-energy-lw165-23-p1310x990/) Lightway Green New Energy | 165.0 W | -5.0 W | 29.0 V | 10.19% | 88.8% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Mitsubishi Electric PV-UD170MF5?

Evaluate Mitsubishi Electric PV-UD170MF5 (170.0 W STC, 29.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Mitsubishi Electric PV-UD170MF5 reaches 34.8 V per panel—exceeding 17 panels in series voids 600 V inverter warranties.
- Footprint constraint: 48 panels for an 8 kW build require 715 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 48 panels (715 sq ft).
- 2026 tax credit baseline: cash residential installs of Mitsubishi Electric PV-UD170MF5 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Mitsubishi Electric PV-UD170MF5 8 kW Residential Fit

Needs 48 modules (715 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 17 panels (-10 C) or 17 panels (-20 C), or compare Lightway Green New Energy LW170(23)P1310x990.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 150.9 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Mitsubishi Electric PV-UD170MF5 by Mitsubishi Electric grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Mitsubishi Electric PV-UD170MF5 PTC wattage (150.9 W) lower than STC (170.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 150.9 W PTC (88.8% retention) across Mitsubishi Electric PV-UD170MF5's 1.383 m2 aperture.

### Who should skip Mitsubishi Electric PV-UD170MF5 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 48 Mitsubishi Electric PV-UD170MF5 panels (715 sq ft) leave unusable roof gaps vs. Lightway Green New Energy LW170(23)P1310x990.

### What is the 1,000 V commercial string limit for Mitsubishi Electric PV-UD170MF5?

On 1,000 V commercial inverters at -10 C (33.71 V cold Voc), Mitsubishi Electric PV-UD170MF5 fits up to 29 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Mitsubishi Electric PV-UD170MF5.

## Related Pages

Compare Mitsubishi Electric equipment, Lightway Green New Energy LW170(23)P1310x990 specs, utility payback rates, and NEC string calculators alongside Mitsubishi Electric PV-UD170MF5.

[All Mitsubishi Electric Certified Solar Models](https://epri-peac.com/solar-equipment/brands/mitsubishi-electric/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Mitsubishi Electric

- [All Mitsubishi Electric Specs](https://epri-peac.com/solar-equipment/brands/mitsubishi-electric/)
- [Mitsubishi Electric PV-MJE280FB](https://epri-peac.com/solar-equipment/modules/mitsubishi-electric/mitsubishi-electric-pv-mje280fb/)
- [Mitsubishi Electric PV-MJE280FB-B](https://epri-peac.com/solar-equipment/modules/mitsubishi-electric/mitsubishi-electric-pv-mje280fb-b/)
- [Mitsubishi Electric PV-MLE280HD2](https://epri-peac.com/solar-equipment/modules/mitsubishi-electric/mitsubishi-electric-pv-mle280hd2/)
- [Mitsubishi Electric PV-MJE270FB](https://epri-peac.com/solar-equipment/modules/mitsubishi-electric/mitsubishi-electric-pv-mje270fb/)
- [Mitsubishi Electric PV-MLE270HD2](https://epri-peac.com/solar-equipment/modules/mitsubishi-electric/mitsubishi-electric-pv-mle270hd2/)