---
title: "Mitsubishi Electric PV-MLE280HD2 Specs (280.0W, 38.6V Voc)"
url: https://epri-peac.com/solar-equipment/modules/mitsubishi-electric/mitsubishi-electric-pv-mle280hd2/
description: "CEC datasheet for Mitsubishi Electric PV-MLE280HD2: 280.0W STC, 38.6V Voc, 29-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Mitsubishi Electric PV-MLE280HD2 — CEC Solar Module Specifications

Manufacturer: [**Mitsubishi Electric**](https://epri-peac.com/solar-equipment/brands/mitsubishi-electric/) Registry: **CEC Verified Engineering Specification**

Mitsubishi Electric PV-MLE280HD2 is a 280.0 W STC (252.1 W PTC) Mono-c-Si solar module ranking #17,941 of 21,677 CEC listings (below all-CEC median; higher than 15.8% of peers). It delivers 19.18% efficiency, 38.6 V Voc at 25 C, and 43.15 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 280.0 W

- **PTC Wattage** : 252.1 W

- **Voc @ 25C** : 38.6 V

- **Efficiency** : 19.18%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Mitsubishi Electric PV-MLE280HD2 Compare Against Peer CEC Listings?

Solar engineering breakdown for Mitsubishi Electric PV-MLE280HD2: PTC thermal retention, roof footprint, and cold Voc string bounds. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Across 5,889 Mono-c-Si listings from Mitsubishi Electric and peers, Mitsubishi Electric PV-MLE280HD2 stands 130.0 W below the 410.0 W Mono-c-Si median and typical 90.0% PTC-to-STC thermal output (252.1 W real-world rating). Sizing 6 kW (22 panels) to 10 kW (36 panels) yields $1,542-$2,523/yr in baseline US bill offset. Lower 38.6 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters.

## Where Does Mitsubishi Electric PV-MLE280HD2 Fall Across Listed CEC Models?

Distribution marker showing Mitsubishi Electric PV-MLE280HD2 (280.0 W) relative to the 385.0 W all-CEC solar panel median. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

## What Dataset Percentiles Define Mitsubishi Electric PV-MLE280HD2?

Dataset percentiles tracking Mitsubishi Electric PV-MLE280HD2 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

## What Do the Dataset Ranks Show for Mitsubishi Electric PV-MLE280HD2?

Benchmark highlights for Mitsubishi Electric PV-MLE280HD2 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Rank #17,941 / 21,677

### 280.0 W STC · Higher Than 15.8%

280.0 W STC (-105.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #13,034

### 19.18% Aperture Efficiency

Power density 191.8 W/m2 (0.73 percentage points below 19.91% CEC median). PTC/STC ratio: 90.0% (rank #18,995).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.15 V at -10 C (560.9 V string) and 44.45 V at -20 C (13 max).

 8 kW Reference Array

### 29 Panels = 8,120 W STC

Occupies 42.3 m2 (456 sq ft) producing 7,311 W PTC; NEC 690.8 OCPD floor is 14.62 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.6 * (1 + (-0.337/100) * (-10 - 25)) = 43.15 V | OCPD = 1.56 * 9.37 = 14.62 A

Inputs from CEC Modules.csv for Mitsubishi Electric PV-MLE280HD2: Voc=38.6 V, beta_Voc=-0.337%/C, Isc=9.37 A, STC=280.0 W, Area=1.46 m2.

**Result:** 13 panels max on 600 V (560.9 V); 29 panels for 8 kW (456 sq ft).

## What Are the Published CEC Specifications for Mitsubishi Electric PV-MLE280HD2?

Official CEC datasheet figures for Mitsubishi Electric PV-MLE280HD2 (Mono-c-Si) used in utility interconnection and permit reviews. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Official California Energy Commission (NREL SAM) test parameters for Mitsubishi Electric PV-MLE280HD2.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 280.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 252.1 W (90.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 38.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.37 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 32.4 V / 8.68 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.337 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 19.18% (1.46 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Mitsubishi Electric PV-MLE280HD2 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Mitsubishi Electric PV-MLE280HD2 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 22 | 6.16 kW | 346 sq ft | $1,542 | $2,607 |
| **8 kW Class** | 29 | 8.12 kW | 456 sq ft | $2,032 | $3,437 |
| **10 kW Class** | 36 | 10.08 kW | 566 sq ft | $2,523 | $4,266 |

## Which Sibling Wattage & Trim Variants Belong to This Mitsubishi Electric Series?

Consolidated Mitsubishi Electric wattage variants sharing the Mitsubishi Electric PV-MLE280HD2 mechanical and cell layout. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sibling CEC listings grouped into the Mitsubishi Electric PV-MLE280HD2 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Mitsubishi Electric PV-MLE275HD2** | 275.0 W | 247.4 W | 38.5 V | 32.1 V | 18.83% |
| **Mitsubishi Electric PV-MLE280HD2** | 280.0 W | 252.1 W | 38.6 V | 32.4 V | 19.18% |

## How Many Mitsubishi Electric PV-MLE280HD2 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Mitsubishi Electric PV-MLE280HD2 (43.15 V at 14 F).

Computed from Voc=38.6V and beta_Voc=-0.337%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 44.45 V | 13 panels | 577.9 V | 22 panels |
| **-10 C (14 F)** | 43.15 V | 13 panels | 560.9 V | 23 panels |
| **0 C (32 F)** | 41.85 V | 14 panels | 585.9 V | 23 panels |
| **25 C (77 F STC)** | 38.6 V | 15 panels | 579.0 V | 25 panels |

## Which Cross-Brand Solar Modules Compare Closest to Mitsubishi Electric PV-MLE280HD2?

Competing CEC solar panels closest to Mitsubishi Electric PV-MLE280HD2 in nameplate wattage and Voc, starting with GermanSolar USA Inc GSP-280W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**GermanSolar USA Inc GSP-280W**](https://epri-peac.com/solar-equipment/modules/germansolar-usa-inc/germansolar-usa-inc-gsp-280w/) GermanSolar USA Inc | 280.0 W | Tie (0 W) | 38.55 V | 16.87% | 92.1% |
| [**Centrosolar America TM6 280xx**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-tm6-280xx/) Centrosolar America | 280.0 W | Tie (0 W) | 38.7 V | 17.14% | 90.6% |
| [**Centrosolar America TM6S 280xx**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-tm6s-280xx/) Centrosolar America | 280.0 W | Tie (0 W) | 38.7 V | 17.14% | 90.6% |
| [**CSI Solar Co Ltd CS6P-280M**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-280m/) CSI Solar Co Ltd | 280.0 W | Tie (0 W) | 38.5 V | 18.08% | 90.8% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Mitsubishi Electric PV-MLE280HD2?

Evaluate Mitsubishi Electric PV-MLE280HD2 (280.0 W STC, 38.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Mitsubishi Electric PV-MLE280HD2 reaches 44.45 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 29 panels for an 8 kW build require 456 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (456 sq ft).
- 2026 tax credit baseline: cash residential installs of Mitsubishi Electric PV-MLE280HD2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Mitsubishi Electric PV-MLE280HD2 8 kW Residential Fit

Needs 29 modules (456 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare GermanSolar USA Inc GSP-280W.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 252.1 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Mitsubishi Electric PV-MLE280HD2 by Mitsubishi Electric grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Mitsubishi Electric PV-MLE280HD2?

Multiplying Mitsubishi Electric PV-MLE280HD2's 9.37 A short-circuit current by 1.56 equals 14.62 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can Mitsubishi Electric PV-MLE280HD2 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 43.15 V cold Voc at 14 F and handles 9.37 A Isc; string inverters cap Mitsubishi Electric PV-MLE280HD2 at 13 panels on 600 V.

### Is Mitsubishi Electric PV-MLE280HD2 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Mitsubishi Electric PV-MLE280HD2 rely on utility bill offset (~$2,032/yr at 8 kW) rather than 25D.

## Related Pages

Compare Mitsubishi Electric equipment, GermanSolar USA Inc GSP-280W specs, utility payback rates, and NEC string calculators alongside Mitsubishi Electric PV-MLE280HD2.

[All Mitsubishi Electric Certified Solar Models](https://epri-peac.com/solar-equipment/brands/mitsubishi-electric/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Mitsubishi Electric

- [All Mitsubishi Electric Specs](https://epri-peac.com/solar-equipment/brands/mitsubishi-electric/)
- [Mitsubishi Electric PV-MJE280FB](https://epri-peac.com/solar-equipment/modules/mitsubishi-electric/mitsubishi-electric-pv-mje280fb/)
- [Mitsubishi Electric PV-MJE280FB-B](https://epri-peac.com/solar-equipment/modules/mitsubishi-electric/mitsubishi-electric-pv-mje280fb-b/)
- [Mitsubishi Electric PV-MJE270FB](https://epri-peac.com/solar-equipment/modules/mitsubishi-electric/mitsubishi-electric-pv-mje270fb/)
- [Mitsubishi Electric PV-MLE270HD2](https://epri-peac.com/solar-equipment/modules/mitsubishi-electric/mitsubishi-electric-pv-mle270hd2/)
- [Mitsubishi Electric PV-MLE265HD](https://epri-peac.com/solar-equipment/modules/mitsubishi-electric/mitsubishi-electric-pv-mle265hd/)
