title: "Mitsubishi Electric PV-EE130MF5F Specs (130.0W, 21.9V Voc)"
url: https://epri-peac.com/solar-equipment/modules/mitsubishi-electric/mitsubishi-electric-pv-ee130mf5f/
description: "CEC datasheet for Mitsubishi Electric PV-EE130MF5F: 130.0W STC, 21.9V Voc, 62-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Mitsubishi Electric PV-EE130MF5F — CEC Solar Module Specifications

Manufacturer: [**Mitsubishi Electric**](https://epri-peac.com/solar-equipment/brands/mitsubishi-electric/) Registry: **CEC Verified Engineering Specification**

Mitsubishi Electric PV-EE130MF5F is a 130.0 W STC (117.0 W PTC) Multi-c-Si solar module ranking #21,472 of 21,677 CEC listings (below all-CEC median; higher than 0.9% of peers). It delivers 12.9% efficiency, 21.9 V Voc at 25 C, and 24.69 V cold Voc at -10 C (24 panels max per 600 V string).

- **STC Wattage** : 130.0 W

- **PTC Wattage** : 117.0 W

- **Voc @ 25C** : 21.9 V

- **Efficiency** : 12.9%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Mitsubishi Electric PV-EE130MF5F Compare Against Peer CEC Listings?

How Mitsubishi Electric Mitsubishi Electric PV-EE130MF5F handles rooftop heat (117.0 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Mitsubishi Electric PV-EE130MF5F exhibits 8.05 A short-circuit current, requiring a 12.56 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #21,472 of 21,677 (148.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 62.5 m2 for an 8 kW system (77 panels for 10 kW). Lower 21.9 V string voltage fits 24 panels in series at 14 F and pairs easily with microinverters.

## Where Does Mitsubishi Electric PV-EE130MF5F Fall Across Listed CEC Models?

Where Mitsubishi Electric PV-EE130MF5F (130.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Mitsubishi Electric PV-EE130MF5F?

Percentile placement of Mitsubishi Electric PV-EE130MF5F across power density (129.0 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Mitsubishi Electric PV-EE130MF5F?

Four critical engineering numbers homeowners and solar installers check first when reviewing Mitsubishi Electric PV-EE130MF5F specifications. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Rank #21,472 / 21,677

### 130.0 W STC · Higher Than 0.9%

130.0 W STC (-255.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,440

### 12.9% Aperture Efficiency

Power density 129.0 W/m2 (7.01 percentage points below 19.91% CEC median). PTC/STC ratio: 90.0% (rank #18,995).

NEC 690.7 Limit

### 24 Panels Max @ -10 C (600 V)

Cold Voc reaches 24.69 V at -10 C (592.6 V string) and 25.49 V at -20 C (23 max).

 8 kW Reference Array

### 62 Panels = 8,060 W STC

Occupies 62.5 m2 (673 sq ft) producing 7,254 W PTC; NEC 690.8 OCPD floor is 12.56 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 21.9 * (1 + (-0.364/100) * (-10 - 25)) = 24.69 V | OCPD = 1.56 * 8.05 = 12.56 A

Inputs from CEC Modules.csv for Mitsubishi Electric PV-EE130MF5F: Voc=21.9 V, beta_Voc=-0.364%/C, Isc=8.05 A, STC=130.0 W, Area=1.008 m2.

**Result:** 24 panels max on 600 V (592.6 V); 62 panels for 8 kW (673 sq ft).

## What Are the Published CEC Specifications for Mitsubishi Electric PV-EE130MF5F?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Mitsubishi Electric PV-EE130MF5F.

Official California Energy Commission (NREL SAM) test parameters for Mitsubishi Electric PV-EE130MF5F.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 130.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 117.0 W (90.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 21.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.05 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 17.4 V / 7.47 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.364 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 12.9% (1.008 m2) | Array roof footprint density |
| **Cell Count & Technology** | 36 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Mitsubishi Electric PV-EE130MF5F Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Mitsubishi Electric PV-EE130MF5F (130.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 47 | 6.11 kW | 510 sq ft | $1,529 | $2,586 |
| **8 kW Class** | 62 | 8.06 kW | 673 sq ft | $2,017 | $3,411 |
| **10 kW Class** | 77 | 10.01 kW | 835 sq ft | $2,505 | $4,236 |

## Which Sibling Wattage & Trim Variants Belong to This Mitsubishi Electric Series?

All closely matched Mitsubishi Electric wattages and cosmetic trims sharing the Mitsubishi Electric PV-EE130MF5F architecture. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Sibling CEC listings grouped into the Mitsubishi Electric PV-EE130MF5F wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Mitsubishi Electric PV-EE125MF5F** | 125.0 W | 112.4 W | 21.8 V | 17.3 V | 12.41% |
| **Mitsubishi Electric PV-EE130MF5F** | 130.0 W | 117.0 W | 21.9 V | 17.4 V | 12.9% |

## How Many Mitsubishi Electric PV-EE130MF5F Modules Fit in a Cold-Weather String?

Maximum series module counts for Mitsubishi Electric PV-EE130MF5F from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=21.9V and beta_Voc=-0.364%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 25.49 V | 23 panels | 586.3 V | 39 panels |
| **-10 C (14 F)** | 24.69 V | 24 panels | 592.6 V | 40 panels |
| **0 C (32 F)** | 23.89 V | 25 panels | 597.2 V | 41 panels |
| **25 C (77 F STC)** | 21.9 V | 27 panels | 591.3 V | 45 panels |

## Which Cross-Brand Solar Modules Compare Closest to Mitsubishi Electric PV-EE130MF5F?

Alternative CEC solar modules from competing brands near Mitsubishi Electric PV-EE130MF5F (130.0 W), including WAAREE ENERGIES LIMITED WU-130.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**WAAREE ENERGIES LIMITED WU-130**](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-wu-130/) WAAREE ENERGIES LIMITED | 130.0 W | Tie (0 W) | 21.0 V | 13.22% | 88.8% |
| [**Gintung Energy ASEC-135G6M**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-135g6m/) Gintung Energy | 135.0 W | +5.0 W | 22.1 V | 13.74% | 89.3% |
| [**United Renewable Energy Co Ltd D6P135A1F**](https://epri-peac.com/solar-equipment/modules/united-renewable-energy-co-ltd/united-renewable-energy-co-ltd-d6p135a1f/) United Renewable Energy Co Ltd | 135.0 W | +5.0 W | 22.1 V | 13.74% | 89.3% |
| [**Gintung Energy ASEC-135G6S**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-135g6s/) Gintung Energy | 135.0 W | +5.0 W | 22.15 V | 13.74% | 89.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Mitsubishi Electric PV-EE130MF5F?

Evaluate Mitsubishi Electric PV-EE130MF5F (130.0 W STC, 21.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Mitsubishi Electric PV-EE130MF5F reaches 25.49 V per panel—exceeding 23 panels in series voids 600 V inverter warranties.
- Footprint constraint: 62 panels for an 8 kW build require 673 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 62 panels (673 sq ft).
- 2026 tax credit baseline: cash residential installs of Mitsubishi Electric PV-EE130MF5F carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Mitsubishi Electric PV-EE130MF5F 8 kW Residential Fit

Needs 62 modules (673 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 24 panels (-10 C) or 23 panels (-20 C), or compare WAAREE ENERGIES LIMITED WU-130.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 117.0 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Mitsubishi Electric PV-EE130MF5F by Mitsubishi Electric grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Mitsubishi Electric PV-EE130MF5F PTC wattage (117.0 W) lower than STC (130.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 117.0 W PTC (90.0% retention) across Mitsubishi Electric PV-EE130MF5F's 1.008 m2 aperture.

### Who should skip Mitsubishi Electric PV-EE130MF5F on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 62 Mitsubishi Electric PV-EE130MF5F panels (673 sq ft) leave unusable roof gaps vs. WAAREE ENERGIES LIMITED WU-130.

### What is the 1,000 V commercial string limit for Mitsubishi Electric PV-EE130MF5F?

On 1,000 V commercial inverters at -10 C (24.69 V cold Voc), Mitsubishi Electric PV-EE130MF5F fits up to 40 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Mitsubishi Electric PV-EE130MF5F.

## Related Pages

Compare Mitsubishi Electric equipment, WAAREE ENERGIES LIMITED WU-130 specs, utility payback rates, and NEC string calculators alongside Mitsubishi Electric PV-EE130MF5F.

[All Mitsubishi Electric Certified Solar Models](https://epri-peac.com/solar-equipment/brands/mitsubishi-electric/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Mitsubishi Electric

- [All Mitsubishi Electric Specs](https://epri-peac.com/solar-equipment/brands/mitsubishi-electric/)
- [Mitsubishi Electric PV-MJE280FB](https://epri-peac.com/solar-equipment/modules/mitsubishi-electric/mitsubishi-electric-pv-mje280fb/)
- [Mitsubishi Electric PV-MJE280FB-B](https://epri-peac.com/solar-equipment/modules/mitsubishi-electric/mitsubishi-electric-pv-mje280fb-b/)
- [Mitsubishi Electric PV-MLE280HD2](https://epri-peac.com/solar-equipment/modules/mitsubishi-electric/mitsubishi-electric-pv-mle280hd2/)
- [Mitsubishi Electric PV-MJE270FB](https://epri-peac.com/solar-equipment/modules/mitsubishi-electric/mitsubishi-electric-pv-mje270fb/)
- [Mitsubishi Electric PV-MLE270HD2](https://epri-peac.com/solar-equipment/modules/mitsubishi-electric/mitsubishi-electric-pv-mle270hd2/)