title: "Mitrex M410-I3H Specs (410.0W, 37.25V Voc)"
url: https://epri-peac.com/solar-equipment/modules/mitrex/mitrex-m410-i3h/
description: "CEC datasheet for Mitrex M410-I3H: 410.0W STC, 37.25V Voc, 20-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Mitrex M410-I3H — CEC Solar Module Specifications

Manufacturer: [**Mitrex**](https://epri-peac.com/solar-equipment/brands/mitrex/) Registry: **CEC Verified Engineering Specification**

Mitrex M410-I3H is a 410.0 W STC (381.7 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.03% efficiency, 37.25 V Voc at 25 C, and 40.94 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 410.0 W

- **PTC Wattage** : 381.7 W

- **Voc @ 25C** : 37.25 V

- **Efficiency** : 21.03%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Mitrex M410-I3H Compare Against Peer CEC Listings?

How Mitrex Mitrex M410-I3H handles rooftop heat (381.7 W PTC), 8 kW sizing, and cold winter string voltage.

Mitrex builds the Mitrex M410-I3H (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 210.3 W/m2 (1.12 percentage points above 19.91% CEC median). Compared against ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE410MD-108 (410.0 W), this model holds strong 93.1% PTC-to-STC heat retention (#9,420 of 21,677). Lower 37.25 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 21.45 A overcurrent floor served by a 25 A breaker.

## Where Does Mitrex M410-I3H Fall Across Listed CEC Models?

Where Mitrex M410-I3H (410.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Mitrex M410-I3H?

Percentile placement of Mitrex M410-I3H across power density (210.3 W/m2), thermal retention, and nameplate STC wattage. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

## What Do the Dataset Ranks Show for Mitrex M410-I3H?

Four critical engineering numbers homeowners and solar installers check first when reviewing Mitrex M410-I3H specifications. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Rank #8,539 / 21,677

### Top 41.3% STC Output

410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #6,235

### 21.03% Aperture Efficiency

Power density 210.3 W/m2 (1.12 percentage points above 19.91% CEC median). PTC/STC ratio: 93.1% (rank #9,420).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.94 V at -10 C (573.2 V string) and 41.99 V at -20 C (14 max).

 8 kW Reference Array

### 20 Panels = 8,200 W STC

Occupies 39.0 m2 (420 sq ft) producing 7,634 W PTC; NEC 690.8 OCPD floor is 21.45 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.25 * (1 + (-0.283/100) * (-10 - 25)) = 40.94 V | OCPD = 1.56 * 13.75 = 21.45 A

Inputs from CEC Modules.csv for Mitrex M410-I3H: Voc=37.25 V, beta_Voc=-0.283%/C, Isc=13.75 A, STC=410.0 W, Area=1.95 m2.

**Result:** 14 panels max on 600 V (573.2 V); 20 panels for 8 kW (420 sq ft).

## What Are the Published CEC Specifications for Mitrex M410-I3H?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Mitrex M410-I3H. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Official California Energy Commission (NREL SAM) test parameters for Mitrex M410-I3H.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 410.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 381.7 W (93.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 37.25 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.75 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 31.75 V / 12.92 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.283 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.03% (1.95 m2) | Array roof footprint density |
| **Cell Count & Technology** | 54 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Mitrex M410-I3H Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Mitrex M410-I3H (410.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 15 | 6.15 kW | 315 sq ft | $1,539 | $2,603 |
| **8 kW Class** | 20 | 8.2 kW | 420 sq ft | $2,052 | $3,470 |
| **10 kW Class** | 25 | 10.25 kW | 525 sq ft | $2,565 | $4,338 |

## Which Sibling Wattage & Trim Variants Belong to This Mitrex Series?

All closely matched Mitrex wattages and cosmetic trims sharing the Mitrex M410-I3H architecture. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the Mitrex M410-I3H wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Mitrex M400-I3H** | 400.0 W | 372.1 W | 36.74 V | 31.23 V | 20.51% |
| **Mitrex M405-I3H** | 405.0 W | 376.9 W | 36.94 V | 31.49 V | 20.77% |
| **Mitrex M410-I3H** | 410.0 W | 381.7 W | 37.25 V | 31.75 V | 21.03% |
| **Mitrex M415-I3H** | 415.0 W | 386.5 W | 37.52 V | 32.05 V | 21.28% |

## How Many Mitrex M410-I3H Modules Fit in a Cold-Weather String?

Maximum series module counts for Mitrex M410-I3H from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=37.25V and beta_Voc=-0.283%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 41.99 V | 14 panels | 587.9 V | 23 panels |
| **-10 C (14 F)** | 40.94 V | 14 panels | 573.2 V | 24 panels |
| **0 C (32 F)** | 39.89 V | 15 panels | 598.4 V | 25 panels |
| **25 C (77 F STC)** | 37.25 V | 16 panels | 596.0 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to Mitrex M410-I3H?

Alternative CEC solar modules from competing brands near Mitrex M410-I3H (410.0 W), including ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE410MD-108.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE410MD-108**](https://epri-peac.com/solar-equipment/modules/alternative-energy-ae-solar-co-ltd/alternative-energy-ae-solar-co-ltd-ae410md-108/) ALTERNATIVE ENERGY (AE) SOLAR CO LTD | 410.0 W | Tie (0 W) | 37.23 V | 21.24% | 92.7% |
| [**Dehui Solar Power (Vietnam) CoLtd DH-M154W 410W**](https://epri-peac.com/solar-equipment/modules/dehui-solar-power-vietnam-coltd/dehui-solar-power-vietnam-coltd-dh-m154w-410w/) Dehui Solar Power (Vietnam) CoLtd | 410.0 W | Tie (0 W) | 37.23 V | 21.24% | 92.7% |
| [**ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE410MD-108E**](https://epri-peac.com/solar-equipment/modules/alternative-energy-ae-solar-co-ltd/alternative-energy-ae-solar-co-ltd-ae410md-108e/) ALTERNATIVE ENERGY (AE) SOLAR CO LTD | 410.0 W | Tie (0 W) | 37.3 V | 21.24% | 92.1% |
| [**AXITEC AC-410MH/108VB**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-410mh-108vb/) AXITEC | 410.0 W | Tie (0 W) | 37.3 V | 21.24% | 92.1% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Mitrex M410-I3H?

Evaluate Mitrex M410-I3H (410.0 W STC, 37.25 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Mitrex M410-I3H reaches 41.99 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 420 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Mitrex M410-I3H carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Mitrex M410-I3H 8 kW Residential Fit

Needs 20 modules (420 sq ft) with a 25 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE410MD-108.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 381.7 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Mitrex M410-I3H by Mitrex grounded in CEC test data and NEC 690.7/690.8 limits. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

### What fuse or breaker size does NEC 690.8 require for Mitrex M410-I3H?

Multiplying Mitrex M410-I3H's 13.75 A short-circuit current by 1.56 equals 21.45 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker. Check local building department permit requirements for Mitrex M410-I3H before finalizing component orders.

### Can Mitrex M410-I3H pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 40.94 V cold Voc at 14 F and handles 13.75 A Isc; string inverters cap Mitrex M410-I3H at 14 panels on 600 V.

### Is Mitrex M410-I3H eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Mitrex M410-I3H rely on utility bill offset (~$2,052/yr at 8 kW) rather than 25D.

## Related Pages

Compare Mitrex equipment, ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE410MD-108 specs, utility payback rates, and NEC string calculators alongside Mitrex M410-I3H.

[All Mitrex Certified Solar Models](https://epri-peac.com/solar-equipment/brands/mitrex/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Mitrex

- [All Mitrex Specs](https://epri-peac.com/solar-equipment/brands/mitrex/)
- [Mitrex M440-H1H](https://epri-peac.com/solar-equipment/modules/mitrex/mitrex-m440-h1h/)
- [Mitrex M410-L3H](https://epri-peac.com/solar-equipment/modules/mitrex/mitrex-m410-l3h/)
- [Mitrex M400-A1F](https://epri-peac.com/solar-equipment/modules/mitrex/mitrex-m400-a1f/)
- [Mitrex M400-B1F](https://epri-peac.com/solar-equipment/modules/mitrex/mitrex-m400-b1f/)
- [Mitrex M395-B1F](https://epri-peac.com/solar-equipment/modules/mitrex/mitrex-m395-b1f/)