title: "Mission Solar Energy LLC Specs (365.0W, 41.7V Voc)"
url: https://epri-peac.com/solar-equipment/modules/mission-solar-energy-llc/mission-solar-energy-llc-txi6-365120bb/
description: "CEC datasheet for Mission Solar Energy LLC TXI6-365120BB: 365.0W STC, 41.7V Voc, 22-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Mission Solar Energy LLC TXI6-365120BB — CEC Solar Module Specifications

Manufacturer: [**Mission Solar Energy LLC**](https://epri-peac.com/solar-equipment/brands/mission-solar-energy-llc/) Registry: **CEC Verified Engineering Specification**

Mission Solar Energy LLC TXI6-365120BB is a 365.0 W STC (341.0 W PTC) Mono-c-Si solar module ranking #12,044 of 21,677 CEC listings (below all-CEC median; higher than 42.9% of peers). It delivers 20.05% efficiency, 41.7 V Voc at 25 C, and 45.8 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 365.0 W

- **PTC Wattage** : 341.0 W

- **Voc @ 25C** : 41.7 V

- **Efficiency** : 20.05%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Mission Solar Energy LLC TXI6-365120BB Compare Against Peer CEC Listings?

How Mission Solar Energy LLC Mission Solar Energy LLC TXI6-365120BB handles rooftop heat (341.0 W PTC), 8 kW sizing, and cold winter string voltage.

Mission Solar Energy LLC builds the Mission Solar Energy LLC TXI6-365120BB (Mono-c-Si) as a compact residential or specialty off-grid module delivering 200.5 W/m2 (0.14 percentage points above 19.91% CEC median). Compared against Caterpillar Inc PVC365MP03HA (365.0 W), this model holds strong 93.4% PTC-to-STC heat retention (#7,716 of 21,677). Mid-range 41.7 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, while NEC 690.8 sets a 17.5 A overcurrent floor served by a 20 A breaker.

## Where Does Mission Solar Energy LLC TXI6-365120BB Fall Across Listed CEC Models?

Where Mission Solar Energy LLC TXI6-365120BB (365.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Mission Solar Energy LLC TXI6-365120BB?

Percentile placement of Mission Solar Energy LLC TXI6-365120BB across power density (200.5 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Mission Solar Energy LLC TXI6-365120BB?

Four critical engineering numbers homeowners and solar installers check first when reviewing Mission Solar Energy LLC TXI6-365120BB specifications.

Rank #12,044 / 21,677

### 365.0 W STC · Higher Than 42.9%

365.0 W STC (-20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #10,276

### 20.05% Aperture Efficiency

Power density 200.5 W/m2 (0.14 percentage points above 19.91% CEC median). PTC/STC ratio: 93.4% (rank #7,716).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.8 V at -10 C (595.4 V string) and 46.97 V at -20 C (12 max).

 8 kW Reference Array

### 22 Panels = 8,030 W STC

Occupies 40.0 m2 (431 sq ft) producing 7,502 W PTC; NEC 690.8 OCPD floor is 17.5 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.7 * (1 + (-0.281/100) * (-10 - 25)) = 45.8 V | OCPD = 1.56 * 11.22 = 17.5 A

Inputs from CEC Modules.csv for Mission Solar Energy LLC TXI6-365120BB: Voc=41.7 V, beta_Voc=-0.281%/C, Isc=11.22 A, STC=365.0 W, Area=1.82 m2.

**Result:** 13 panels max on 600 V (595.4 V); 22 panels for 8 kW (431 sq ft).

## What Are the Published CEC Specifications for Mission Solar Energy LLC TXI6-365120BB?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Mission Solar Energy LLC TXI6-365120BB.

Official California Energy Commission (NREL SAM) test parameters for Mission Solar Energy LLC TXI6-365120BB.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 365.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 341.0 W (93.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 41.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 11.22 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 34.2 V / 10.68 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.281 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.05% (1.82 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Mission Solar Energy LLC TXI6-365120BB Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Mission Solar Energy LLC TXI6-365120BB (365.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 17 | 6.21 kW | 333 sq ft | $1,554 | $2,628 |
| **8 kW Class** | 22 | 8.03 kW | 431 sq ft | $2,010 | $3,398 |
| **10 kW Class** | 28 | 10.22 kW | 549 sq ft | $2,558 | $4,325 |

## How Many Mission Solar Energy LLC TXI6-365120BB Modules Fit in a Cold-Weather String?

Maximum series module counts for Mission Solar Energy LLC TXI6-365120BB from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=41.7V and beta_Voc=-0.281%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 46.97 V | 12 panels | 563.6 V | 21 panels |
| **-10 C (14 F)** | 45.8 V | 13 panels | 595.4 V | 21 panels |
| **0 C (32 F)** | 44.63 V | 13 panels | 580.2 V | 22 panels |
| **25 C (77 F STC)** | 41.7 V | 14 panels | 583.8 V | 23 panels |

## Which Cross-Brand Solar Modules Compare Closest to Mission Solar Energy LLC TXI6-365120BB?

Alternative CEC solar modules from competing brands near Mission Solar Energy LLC TXI6-365120BB (365.0 W), including Caterpillar Inc PVC365MP03HA.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Caterpillar Inc PVC365MP03HA**](https://epri-peac.com/solar-equipment/modules/caterpillar-inc/caterpillar-inc-pvc365mp03ha/) Caterpillar Inc | 365.0 W | Tie (0 W) | 41.0 V | 20.62% | 93.5% |
| [**Bluesun Solar CoLtd BSM365M-60HPH**](https://epri-peac.com/solar-equipment/modules/bluesun-solar-coltd/bluesun-solar-coltd-bsm365m-60hph/) Bluesun Solar CoLtd | 365.0 W | Tie (0 W) | 40.9 V | 20.05% | 92.8% |
| [**Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W**](https://epri-peac.com/solar-equipment/modules/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd-as-6m120-bhc-365w/) Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd | 365.0 W | Tie (0 W) | 40.7 V | 20.51% | 92.6% |
| [**Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W**](https://epri-peac.com/solar-equipment/modules/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd-as-6m120-hc-365w/) Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd | 365.0 W | Tie (0 W) | 40.7 V | 20.17% | 92.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Mission Solar Energy LLC TXI6-365120BB?

Evaluate Mission Solar Energy LLC TXI6-365120BB (365.0 W STC, 41.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Mission Solar Energy LLC TXI6-365120BB reaches 46.97 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 431 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (431 sq ft).
- 2026 tax credit baseline: cash residential installs of Mission Solar Energy LLC TXI6-365120BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Mission Solar Energy LLC TXI6-365120BB 8 kW Residential Fit

Needs 22 modules (431 sq ft) with a 20 A string OCPD, offsetting ~$2,010/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Caterpillar Inc PVC365MP03HA.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 341.0 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Mission Solar Energy LLC TXI6-365120BB by Mission Solar Energy LLC grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Mission Solar Energy LLC TXI6-365120BB?

Multiplying Mission Solar Energy LLC TXI6-365120BB's 11.22 A short-circuit current by 1.56 equals 17.5 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

### Can Mission Solar Energy LLC TXI6-365120BB pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 45.8 V cold Voc at 14 F and handles 11.22 A Isc; string inverters cap Mission Solar Energy LLC TXI6-365120BB at 13 panels on 600 V.

### Is Mission Solar Energy LLC TXI6-365120BB eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Mission Solar Energy LLC TXI6-365120BB rely on utility bill offset (~$2,010/yr at 8 kW) rather than 25D.

## Related Pages

Compare Mission Solar Energy LLC equipment, Caterpillar Inc PVC365MP03HA specs, utility payback rates, and NEC string calculators alongside Mission Solar Energy LLC TXI6-365120BB.

[All Mission Solar Energy LLC Certified Solar Models](https://epri-peac.com/solar-equipment/brands/mission-solar-energy-llc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Mission Solar Energy LLC

- [All Mission Solar Energy LLC Specs](https://epri-peac.com/solar-equipment/brands/mission-solar-energy-llc/)
- [Mission Solar Energy LLC MSN12-680HP3T](https://epri-peac.com/solar-equipment/modules/mission-solar-energy-llc/mission-solar-energy-llc-msn12-680hp3t/)
- [Mission Solar Energy LLC MSN12-660HP3T](https://epri-peac.com/solar-equipment/modules/mission-solar-energy-llc/mission-solar-energy-llc-msn12-660hp3t/)
- [Mission Solar Energy LLC MSN12-640HP3T](https://epri-peac.com/solar-equipment/modules/mission-solar-energy-llc/mission-solar-energy-llc-msn12-640hp3t/)
- [Mission Solar Energy LLC MSH10-600HN4G](https://epri-peac.com/solar-equipment/modules/mission-solar-energy-llc/mission-solar-energy-llc-msh10-600hn4g/)
- [Mission Solar Energy LLC MSN10-600HN4G](https://epri-peac.com/solar-equipment/modules/mission-solar-energy-llc/mission-solar-energy-llc-msn10-600hn4g/)