title: "Mission Solar Energy LLC Specs (455.0W, 39.1V Voc)"
url: https://epri-peac.com/solar-equipment/modules/mission-solar-energy-llc/mission-solar-energy-llc-msx10-455hn0b-b/
description: "CEC datasheet for Mission Solar Energy LLC MSX10-455HN0B {B}: 455.0W STC, 39.1V Voc, 18-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# Mission Solar Energy LLC MSX10-455HN0B {B} — CEC Solar Module Specifications

Manufacturer: [**Mission Solar Energy LLC**](https://epri-peac.com/solar-equipment/brands/mission-solar-energy-llc/) Registry: **CEC Verified Engineering Specification**

Mission Solar Energy LLC MSX10-455HN0B {B} is a 455.0 W STC (429.5 W PTC) Mono-c-Si solar module ranking #5,417 of 21,677 CEC listings (top 26.2%; higher than 73.8% of peers). It delivers 23.45% efficiency, 39.1 V Voc at 25 C, and 42.38 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 455.0 W

- **PTC Wattage** : 429.5 W

- **Voc @ 25C** : 39.1 V

- **Efficiency** : 23.45%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Mission Solar Energy LLC MSX10-455HN0B {B} Compare Against Peer CEC Listings?

Solar engineering breakdown for Mission Solar Energy LLC MSX10-455HN0B {B}: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from Mission Solar Energy LLC and peers, Mission Solar Energy LLC MSX10-455HN0B {B} stands 45.0 W above the 410.0 W Mono-c-Si median and strong 94.4% PTC-to-STC heat retention (#2,840 of 21,677). Sizing 6 kW (14 panels) to 10 kW (22 panels) yields $1,594-$2,505/yr in baseline US bill offset. Lower 39.1 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

## Where Does Mission Solar Energy LLC MSX10-455HN0B {B} Fall Across Listed CEC Models?

Distribution marker showing Mission Solar Energy LLC MSX10-455HN0B {B} (455.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define Mission Solar Energy LLC MSX10-455HN0B {B}?

Dataset percentiles tracking Mission Solar Energy LLC MSX10-455HN0B {B} power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for Mission Solar Energy LLC MSX10-455HN0B {B}?

Benchmark highlights for Mission Solar Energy LLC MSX10-455HN0B {B} covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #5,417 / 21,677

### Top 26.2% STC Output

455.0 W STC (+70.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #560

### 23.45% Aperture Efficiency

Power density 234.5 W/m2 (3.54 percentage points above 19.91% CEC median). PTC/STC ratio: 94.4% (rank #2,840).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.38 V at -10 C (593.3 V string) and 43.32 V at -20 C (13 max).

 8 kW Reference Array

### 18 Panels = 8,190 W STC

Occupies 34.9 m2 (376 sq ft) producing 7,731 W PTC; NEC 690.8 OCPD floor is 22.82 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.1 * (1 + (-0.24/100) * (-10 - 25)) = 42.38 V | OCPD = 1.56 * 14.63 = 22.82 A

Inputs from CEC Modules.csv for Mission Solar Energy LLC MSX10-455HN0B {B}: Voc=39.1 V, beta_Voc=-0.24%/C, Isc=14.63 A, STC=455.0 W, Area=1.94 m2.

**Result:** 14 panels max on 600 V (593.3 V); 18 panels for 8 kW (376 sq ft).

## What Are the Published CEC Specifications for Mission Solar Energy LLC MSX10-455HN0B {B}?

Official CEC datasheet figures for Mission Solar Energy LLC MSX10-455HN0B {B} (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Mission Solar Energy LLC MSX10-455HN0B {B}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 455.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 429.5 W (94.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 39.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 14.63 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 32.69 V / 13.92 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.24 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 23.45% (1.94 m2) | Array roof footprint density |
| **Cell Count & Technology** | 54 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Mission Solar Energy LLC MSX10-455HN0B {B} Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Mission Solar Energy LLC MSX10-455HN0B {B} modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 14 | 6.37 kW | 292 sq ft | $1,594 | $2,696 |
| **8 kW Class** | 18 | 8.19 kW | 376 sq ft | $2,050 | $3,466 |
| **10 kW Class** | 22 | 10.01 kW | 459 sq ft | $2,505 | $4,236 |

## Which Sibling Wattage & Trim Variants Belong to This Mission Solar Energy LLC Series?

Consolidated Mission Solar Energy LLC wattage variants sharing the Mission Solar Energy LLC MSX10-455HN0B {B} mechanical and cell layout.

Sibling CEC listings grouped into the Mission Solar Energy LLC MSX10-455HN0B {B} wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Mission Solar Energy LLC MSX10-450HN0B {B}** | 450.0 W | 424.6 W | 38.9 V | 32.5 V | 23.2% |
| **Mission Solar Energy LLC MSX10-455HN0B {B}** | 455.0 W | 429.5 W | 39.1 V | 32.69 V | 23.45% |
| **Mission Solar Energy LLC MSX10-460HN0B {B}** | 460.0 W | 434.3 W | 39.3 V | 32.89 V | 23.71% |

## How Many Mission Solar Energy LLC MSX10-455HN0B {B} Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Mission Solar Energy LLC MSX10-455HN0B {B} (42.38 V at 14 F).

Computed from Voc=39.1V and beta_Voc=-0.24%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 43.32 V | 13 panels | 563.2 V | 23 panels |
| **-10 C (14 F)** | 42.38 V | 14 panels | 593.3 V | 23 panels |
| **0 C (32 F)** | 41.45 V | 14 panels | 580.3 V | 24 panels |
| **25 C (77 F STC)** | 39.1 V | 15 panels | 586.5 V | 25 panels |

## Which Cross-Brand Solar Modules Compare Closest to Mission Solar Energy LLC MSX10-455HN0B {B}?

Competing CEC solar panels closest to Mission Solar Energy LLC MSX10-455HN0B {B} in nameplate wattage and Voc, starting with GermanSolar USA Inc GSM10-108-455W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**GermanSolar USA Inc GSM10-108-455W**](https://epri-peac.com/solar-equipment/modules/germansolar-usa-inc/germansolar-usa-inc-gsm10-108-455w/) GermanSolar USA Inc | 455.0 W | Tie (0 W) | 39.53 V | 25.14% | 95.2% |
| [**ELITE Solar ET-N754TBH455GB**](https://epri-peac.com/solar-equipment/modules/elite-solar/elite-solar-et-n754tbh455gb/) ELITE Solar | 455.0 W | Tie (0 W) | 39.86 V | 23.33% | 95.0% |
| [**ELITE Solar ET-N754TBH455GL**](https://epri-peac.com/solar-equipment/modules/elite-solar/elite-solar-et-n754tbh455gl/) ELITE Solar | 455.0 W | Tie (0 W) | 39.86 V | 23.33% | 95.0% |
| [**AEG SOLAR ENERGY SRL ALPS54D30-455/TP**](https://epri-peac.com/solar-equipment/modules/aeg-solar-energy-srl/aeg-solar-energy-srl-alps54d30-455-tp/) AEG SOLAR ENERGY SRL | 455.0 W | Tie (0 W) | 40.1 V | 22.86% | 94.4% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Mission Solar Energy LLC MSX10-455HN0B {B}?

Evaluate Mission Solar Energy LLC MSX10-455HN0B {B} (455.0 W STC, 39.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Mission Solar Energy LLC MSX10-455HN0B {B} reaches 43.32 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 376 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (376 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Mission Solar Energy LLC MSX10-455HN0B {B} carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Mission Solar Energy LLC MSX10-455HN0B {B} 8 kW Residential Fit

Needs 18 modules (376 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare GermanSolar USA Inc GSM10-108-455W.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 429.5 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Mission Solar Energy LLC MSX10-455HN0B {B} by Mission Solar Energy LLC grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Mission Solar Energy LLC MSX10-455HN0B {B}?

Multiplying Mission Solar Energy LLC MSX10-455HN0B {B}'s 14.63 A short-circuit current by 1.56 equals 22.82 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can Mission Solar Energy LLC MSX10-455HN0B {B} pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 42.38 V cold Voc at 14 F and handles 14.63 A Isc; string inverters cap Mission Solar Energy LLC MSX10-455HN0B {B} at 14 panels on 600 V.

### Is Mission Solar Energy LLC MSX10-455HN0B {B} eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Mission Solar Energy LLC MSX10-455HN0B {B} rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.

## Related Pages

Compare Mission Solar Energy LLC equipment, GermanSolar USA Inc GSM10-108-455W specs, utility payback rates, and NEC string calculators alongside Mission Solar Energy LLC MSX10-455HN0B {B}.

[All Mission Solar Energy LLC Certified Solar Models](https://epri-peac.com/solar-equipment/brands/mission-solar-energy-llc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Mission Solar Energy LLC

- [All Mission Solar Energy LLC Specs](https://epri-peac.com/solar-equipment/brands/mission-solar-energy-llc/)
- [Mission Solar Energy LLC MSN12-680HP3T](https://epri-peac.com/solar-equipment/modules/mission-solar-energy-llc/mission-solar-energy-llc-msn12-680hp3t/)
- [Mission Solar Energy LLC MSN12-660HP3T](https://epri-peac.com/solar-equipment/modules/mission-solar-energy-llc/mission-solar-energy-llc-msn12-660hp3t/)
- [Mission Solar Energy LLC MSN12-640HP3T](https://epri-peac.com/solar-equipment/modules/mission-solar-energy-llc/mission-solar-energy-llc-msn12-640hp3t/)
- [Mission Solar Energy LLC MSH10-600HN4G](https://epri-peac.com/solar-equipment/modules/mission-solar-energy-llc/mission-solar-energy-llc-msh10-600hn4g/)
- [Mission Solar Energy LLC MSN10-600HN4G](https://epri-peac.com/solar-equipment/modules/mission-solar-energy-llc/mission-solar-energy-llc-msn10-600hn4g/)