# Mission Solar Energy LLC MSE445HT2B — CEC Solar Module Specifications

Manufacturer: [**Mission Solar Energy LLC**](https://epri-peac.com/solar-equipment/brands/mission-solar-energy-llc/) Registry: **CEC Verified Engineering Specification**

Mission Solar Energy LLC MSE445HT2B is a 445.0 W STC (416.9 W PTC) Mono-c-Si solar module ranking #6,028 of 21,677 CEC listings (top 29.6%; higher than 70.4% of peers). It delivers 21.19% efficiency, 41.15 V Voc at 25 C, and 44.75 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 445.0 W

- **PTC Wattage** : 416.9 W

- **Voc @ 25C** : 41.15 V

- **Efficiency** : 21.19%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Mission Solar Energy LLC MSE445HT2B Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Mission Solar Energy LLC MSE445HT2B (Mono-c-Si) residential solar systems.

Mission Solar Energy LLC MSE445HT2B delivers 211.9 W/m2 (1.28 percentage points above 19.91% CEC median) and strong 93.7% PTC-to-STC heat retention (#6,162 of 21,677), placing it as a modern high-density residential and light-commercial module well-proportioned for residential pitched roofs needing 18 panels (407 sq ft) for an 8 kW array. At -4 F (-20 C), string voltage climbs to 45.78 V per unit, capping 600 V circuits at 13 panels. Compare specs directly with ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE445MD-120 (445.0 W).

## Where Does Mission Solar Energy LLC MSE445HT2B Fall Across Listed CEC Models?

Comparison of Mission Solar Energy LLC MSE445HT2B (445.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define Mission Solar Energy LLC MSE445HT2B?

Relative ranking of Mission Solar Energy LLC MSE445HT2B across nameplate watts, 93.7% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for Mission Solar Energy LLC MSE445HT2B?

Summary of Mission Solar Energy LLC MSE445HT2B output rank, 8 kW array size (18 panels), efficiency rating, and 600 V string limit.

Rank #6,028 / 21,677

### Top 29.6% STC Output

445.0 W STC (+60.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,621

### 21.19% Aperture Efficiency

Power density 211.9 W/m2 (1.28 percentage points above 19.91% CEC median). PTC/STC ratio: 93.7% (rank #6,162).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.75 V at -10 C (581.8 V string) and 45.78 V at -20 C (13 max).

 8 kW Reference Array

### 18 Panels = 8,010 W STC

Occupies 37.8 m2 (407 sq ft) producing 7,504 W PTC; NEC 690.8 OCPD floor is 21.45 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.15 * (1 + (-0.25/100) * (-10 - 25)) = 44.75 V | OCPD = 1.56 * 13.75 = 21.45 A

Inputs from CEC Modules.csv for Mission Solar Energy LLC MSE445HT2B: Voc=41.15 V, beta_Voc=-0.25%/C, Isc=13.75 A, STC=445.0 W, Area=2.1 m2.

**Result:** 13 panels max on 600 V (581.8 V); 18 panels for 8 kW (407 sq ft).

## What Are the Published CEC Specifications for Mission Solar Energy LLC MSE445HT2B?

Complete CEC test sheet for Mission Solar Energy LLC MSE445HT2B including Isc (13.75 A), Voc (41.15 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Mission Solar Energy LLC MSE445HT2B.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 445.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 416.9 W (93.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 41.15 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.75 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 34.06 V / 13.07 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.25 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.19% (2.1 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Mission Solar Energy LLC MSE445HT2B Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Mission Solar Energy LLC MSE445HT2B.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 14 | 6.23 kW | 316 sq ft | $1,559 | $2,637 |
| **8 kW Class** | 18 | 8.01 kW | 407 sq ft | $2,005 | $3,390 |
| **10 kW Class** | 23 | 10.23 kW | 520 sq ft | $2,560 | $4,330 |

## Which Sibling Wattage & Trim Variants Belong to This Mission Solar Energy LLC Series?

Related Mission Solar Energy LLC power steps and black/silver trims consolidated into this Mission Solar Energy LLC MSE445HT2B series guide.

Sibling CEC listings grouped into the Mission Solar Energy LLC MSE445HT2B wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Mission Solar Energy LLC MSE440HT2B** | 440.0 W | 412.1 W | 41.01 V | 33.91 V | 20.95% |
| **Mission Solar Energy LLC MSE445HT2B** | 445.0 W | 416.9 W | 41.15 V | 34.06 V | 21.19% |

## How Many Mission Solar Energy LLC MSE445HT2B Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Mission Solar Energy LLC MSE445HT2B (41.15 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=41.15V and beta_Voc=-0.25%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 45.78 V | 13 panels | 595.1 V | 21 panels |
| **-10 C (14 F)** | 44.75 V | 13 panels | 581.8 V | 22 panels |
| **0 C (32 F)** | 43.72 V | 13 panels | 568.4 V | 22 panels |
| **25 C (77 F STC)** | 41.15 V | 14 panels | 576.1 V | 24 panels |

## Which Cross-Brand Solar Modules Compare Closest to Mission Solar Energy LLC MSE445HT2B?

Four comparable CEC modules such as ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE445MD-120 (445.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE445MD-120**](https://epri-peac.com/solar-equipment/modules/alternative-energy-ae-solar-co-ltd/alternative-energy-ae-solar-co-ltd-ae445md-120/) ALTERNATIVE ENERGY (AE) SOLAR CO LTD | 445.0 W | Tie (0 W) | 41.1 V | 20.79% | 92.9% |
| [**ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE445MD-120E**](https://epri-peac.com/solar-equipment/modules/alternative-energy-ae-solar-co-ltd/alternative-energy-ae-solar-co-ltd-ae445md-120e/) ALTERNATIVE ENERGY (AE) SOLAR CO LTD | 445.0 W | Tie (0 W) | 41.1 V | 20.79% | 92.6% |
| [**Aptos Solar Technology LLC DNA-120-MF10-445W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-120-mf10-445w/) Aptos Solar Technology LLC | 445.0 W | Tie (0 W) | 41.1 V | 20.79% | 93.7% |
| [**CertainTeed CTM10445HC11-06**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ctm10445hc11-06/) CertainTeed | 445.0 W | Tie (0 W) | 41.1 V | 20.6% | 93.8% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Mission Solar Energy LLC MSE445HT2B?

Evaluate Mission Solar Energy LLC MSE445HT2B (445.0 W STC, 41.15 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Mission Solar Energy LLC MSE445HT2B reaches 45.78 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 407 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (407 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Mission Solar Energy LLC MSE445HT2B carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Mission Solar Energy LLC MSE445HT2B 8 kW Residential Fit

Needs 18 modules (407 sq ft) with a 25 A string OCPD, offsetting ~$2,005/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE445MD-120.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 416.9 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Mission Solar Energy LLC MSE445HT2B by Mission Solar Energy LLC grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Mission Solar Energy LLC MSE445HT2B panels fit on a 600 V winter solar string?

At -10 C (14 F), Mission Solar Energy LLC MSE445HT2B cold Voc rises from 41.15 V to 44.75 V (beta_Voc -0.25%/C), capping a 600 V string at 13 panels (581.8 V).

### How much roof area does an 8 kW array of Mission Solar Energy LLC MSE445HT2B need?

An 8 kW DC system uses 18 Mission Solar Energy LLC MSE445HT2B modules (8,010 W STC / 7,504 W PTC), covering roughly 407 sq ft and saving ~$2,005/yr at 18.54 c/kWh.

### How does Mission Solar Energy LLC MSE445HT2B compare against ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE445MD-120?

Mission Solar Energy LLC MSE445HT2B outputs 445.0 W STC (41.15 V Voc, rank #6,028 of 21,677), while ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE445MD-120 delivers 445.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Mission Solar Energy LLC equipment, ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE445MD-120 specs, utility payback rates, and NEC string calculators alongside Mission Solar Energy LLC MSE445HT2B.

[All Mission Solar Energy LLC Certified Solar Models](https://epri-peac.com/solar-equipment/brands/mission-solar-energy-llc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Mission Solar Energy LLC

- [All Mission Solar Energy LLC Specs](https://epri-peac.com/solar-equipment/brands/mission-solar-energy-llc/)
- [Mission Solar Energy LLC MSN12-680HP3T](https://epri-peac.com/solar-equipment/modules/mission-solar-energy-llc/mission-solar-energy-llc-msn12-680hp3t/)
- [Mission Solar Energy LLC MSN12-660HP3T](https://epri-peac.com/solar-equipment/modules/mission-solar-energy-llc/mission-solar-energy-llc-msn12-660hp3t/)
- [Mission Solar Energy LLC MSN12-640HP3T](https://epri-peac.com/solar-equipment/modules/mission-solar-energy-llc/mission-solar-energy-llc-msn12-640hp3t/)
- [Mission Solar Energy LLC MSH10-600HN4G](https://epri-peac.com/solar-equipment/modules/mission-solar-energy-llc/mission-solar-energy-llc-msh10-600hn4g/)
- [Mission Solar Energy LLC MSN10-600HN4G](https://epri-peac.com/solar-equipment/modules/mission-solar-energy-llc/mission-solar-energy-llc-msn10-600hn4g/)