title: "Mission Solar Energy LLC Specs (295.0W, 44.8V Voc)"
url: https://epri-peac.com/solar-equipment/modules/mission-solar-energy-llc/mission-solar-energy-llc-mse295sb1a/
description: "CEC datasheet for Mission Solar Energy LLC MSE295SB1A: 295.0W STC, 44.8V Voc, 28-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Mission Solar Energy LLC MSE295SB1A — CEC Solar Module Specifications

Manufacturer: [**Mission Solar Energy LLC**](https://epri-peac.com/solar-equipment/brands/mission-solar-energy-llc/) Registry: **CEC Verified Engineering Specification**

Mission Solar Energy LLC MSE295SB1A is a 295.0 W STC (263.4 W PTC) Mono-c-Si solar module ranking #16,890 of 21,677 CEC listings (below all-CEC median; higher than 20.4% of peers). It delivers 15.13% efficiency, 44.8 V Voc at 25 C, and 50.01 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 295.0 W

- **PTC Wattage** : 263.4 W

- **Voc @ 25C** : 44.8 V

- **Efficiency** : 15.13%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Mission Solar Energy LLC MSE295SB1A Compare Against Peer CEC Listings?

Engineering position of Mission Solar Energy LLC MSE295SB1A (295.0 W STC) vs. BYD Company Limited BYD295P6K-36 across 5,889 CEC Mono-c-Si solar modules.

Ranking #16,890 across 21,677 CEC solar panels (below all-CEC median; higher than 20.4% of peers), Mission Solar Energy LLC MSE295SB1A operates as a compact residential or specialty off-grid module sitting 115.0 W below the 410.0 W Mono-c-Si median. Mid-range 44.8 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F. With typical 89.3% PTC-to-STC thermal output (263.4 W real-world rating), 28 panels occupy 588 sq ft and offset roughly $2,067/yr at average US rates (or $3,496/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does Mission Solar Energy LLC MSE295SB1A Fall Across Listed CEC Models?

Plots Mission Solar Energy LLC MSE295SB1A at 295.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define Mission Solar Energy LLC MSE295SB1A?

Benchmarks Mission Solar Energy LLC MSE295SB1A on STC wattage, thermal PTC/STC retention, and 15.13 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for Mission Solar Energy LLC MSE295SB1A?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Mission Solar Energy LLC MSE295SB1A by Mission Solar Energy LLC.

Rank #16,890 / 21,677

### 295.0 W STC · Higher Than 20.4%

295.0 W STC (-90.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #19,550

### 15.13% Aperture Efficiency

Power density 151.3 W/m2 (4.78 percentage points below 19.91% CEC median). PTC/STC ratio: 89.3% (rank #20,205).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.01 V at -10 C (550.1 V string) and 51.49 V at -20 C (11 max).

 8 kW Reference Array

### 28 Panels = 8,260 W STC

Occupies 54.6 m2 (588 sq ft) producing 7,375 W PTC; NEC 690.8 OCPD floor is 13.71 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.8 * (1 + (-0.332/100) * (-10 - 25)) = 50.01 V | OCPD = 1.56 * 8.79 = 13.71 A

Inputs from CEC Modules.csv for Mission Solar Energy LLC MSE295SB1A: Voc=44.8 V, beta_Voc=-0.332%/C, Isc=8.79 A, STC=295.0 W, Area=1.95 m2.

**Result:** 11 panels max on 600 V (550.1 V); 28 panels for 8 kW (588 sq ft).

## What Are the Published CEC Specifications for Mission Solar Energy LLC MSE295SB1A?

Laboratory test ratings recorded for Mission Solar Energy LLC MSE295SB1A (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Mission Solar Energy LLC MSE295SB1A.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 295.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 263.4 W (89.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 44.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.79 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 36.3 V / 8.19 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.332 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.13% (1.95 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Mission Solar Energy LLC MSE295SB1A Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (588 sq ft at 8 kW), and estimated Year-1 electric bill offset for Mission Solar Energy LLC MSE295SB1A.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 21 | 6.2 kW | 441 sq ft | $1,552 | $2,624 |
| **8 kW Class** | 28 | 8.26 kW | 588 sq ft | $2,067 | $3,496 |
| **10 kW Class** | 34 | 10.03 kW | 714 sq ft | $2,510 | $4,245 |

## Which Sibling Wattage & Trim Variants Belong to This Mission Solar Energy LLC Series?

Sibling wattage bins and frame colors grouped with Mission Solar Energy LLC MSE295SB1A under Mission Solar Energy LLC to prevent duplicate spec pages.

Sibling CEC listings grouped into the Mission Solar Energy LLC MSE295SB1A wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Mission Solar Energy LLC MSE290SB1A** | 290.0 W | 258.8 W | 44.5 V | 36.0 V | 14.87% |
| **Mission Solar Energy LLC MSE295SB1A** | 295.0 W | 263.4 W | 44.8 V | 36.3 V | 15.13% |

## How Many Mission Solar Energy LLC MSE295SB1A Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Mission Solar Energy LLC MSE295SB1A (beta_Voc -0.332%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=44.8V and beta_Voc=-0.332%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 51.49 V | 11 panels | 566.4 V | 19 panels |
| **-10 C (14 F)** | 50.01 V | 11 panels | 550.1 V | 19 panels |
| **0 C (32 F)** | 48.52 V | 12 panels | 582.2 V | 20 panels |
| **25 C (77 F STC)** | 44.8 V | 13 panels | 582.4 V | 22 panels |

## Which Cross-Brand Solar Modules Compare Closest to Mission Solar Energy LLC MSE295SB1A?

Closest cross-brand CEC competitors to Mission Solar Energy LLC MSE295SB1A matched near 295.0 W STC and 44.8 V Voc, led by BYD Company Limited BYD295P6K-36.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**BYD Company Limited BYD295P6K-36**](https://epri-peac.com/solar-equipment/modules/byd-company-limited/byd-company-limited-byd295p6k-36/) BYD Company Limited | 295.0 W | Tie (0 W) | 44.9 V | 15.21% | 91.5% |
| [**Centrosolar America TP7 295xx**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-tp7-295xx/) Centrosolar America | 295.0 W | Tie (0 W) | 45.1 V | 15.13% | 90.4% |
| [**Centrosolar America TP7S 295xx**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-tp7s-295xx/) Centrosolar America | 295.0 W | Tie (0 W) | 45.1 V | 15.13% | 90.4% |
| [**Chinaland Solar Energy HSE295-72M**](https://epri-peac.com/solar-equipment/modules/chinaland-solar-energy/chinaland-solar-energy-hse295-72m/) Chinaland Solar Energy | 295.0 W | Tie (0 W) | 44.4 V | 15.28% | 90.2% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Mission Solar Energy LLC MSE295SB1A?

Evaluate Mission Solar Energy LLC MSE295SB1A (295.0 W STC, 44.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Mission Solar Energy LLC MSE295SB1A reaches 51.49 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 28 panels for an 8 kW build require 588 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (588 sq ft).
- 2026 tax credit baseline: cash residential installs of Mission Solar Energy LLC MSE295SB1A carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Mission Solar Energy LLC MSE295SB1A 8 kW Residential Fit

Needs 28 modules (588 sq ft) with a 15 A string OCPD, offsetting ~$2,067/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare BYD Company Limited BYD295P6K-36.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 263.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Mission Solar Energy LLC MSE295SB1A by Mission Solar Energy LLC grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Mission Solar Energy LLC MSE295SB1A panels fit on a 600 V winter solar string?

At -10 C (14 F), Mission Solar Energy LLC MSE295SB1A cold Voc rises from 44.8 V to 50.01 V (beta_Voc -0.332%/C), capping a 600 V string at 11 panels (550.1 V).

### How much roof area does an 8 kW array of Mission Solar Energy LLC MSE295SB1A need?

An 8 kW DC system uses 28 Mission Solar Energy LLC MSE295SB1A modules (8,260 W STC / 7,375 W PTC), covering roughly 588 sq ft and saving ~$2,067/yr at 18.54 c/kWh.

### How does Mission Solar Energy LLC MSE295SB1A compare against BYD Company Limited BYD295P6K-36?

Mission Solar Energy LLC MSE295SB1A outputs 295.0 W STC (44.8 V Voc, rank #16,890 of 21,677), while BYD Company Limited BYD295P6K-36 delivers 295.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Mission Solar Energy LLC equipment, BYD Company Limited BYD295P6K-36 specs, utility payback rates, and NEC string calculators alongside Mission Solar Energy LLC MSE295SB1A.

[All Mission Solar Energy LLC Certified Solar Models](https://epri-peac.com/solar-equipment/brands/mission-solar-energy-llc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Mission Solar Energy LLC

- [All Mission Solar Energy LLC Specs](https://epri-peac.com/solar-equipment/brands/mission-solar-energy-llc/)
- [Mission Solar Energy LLC MSN12-680HP3T](https://epri-peac.com/solar-equipment/modules/mission-solar-energy-llc/mission-solar-energy-llc-msn12-680hp3t/)
- [Mission Solar Energy LLC MSN12-660HP3T](https://epri-peac.com/solar-equipment/modules/mission-solar-energy-llc/mission-solar-energy-llc-msn12-660hp3t/)
- [Mission Solar Energy LLC MSN12-640HP3T](https://epri-peac.com/solar-equipment/modules/mission-solar-energy-llc/mission-solar-energy-llc-msn12-640hp3t/)
- [Mission Solar Energy LLC MSH10-600HN4G](https://epri-peac.com/solar-equipment/modules/mission-solar-energy-llc/mission-solar-energy-llc-msh10-600hn4g/)
- [Mission Solar Energy LLC MSN10-600HN4G](https://epri-peac.com/solar-equipment/modules/mission-solar-energy-llc/mission-solar-energy-llc-msn10-600hn4g/)