title: "Miasole FLEX-03 290W Specs (290.0W, 47.2V Voc)"
url: https://epri-peac.com/solar-equipment/modules/miasole/miasole-flex-03-290w/
description: "CEC datasheet for Miasole FLEX-03 290W: 290.0W STC, 47.2V Voc, 28-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Miasole FLEX-03 290W — CEC Solar Module Specifications

Manufacturer: [**Miasole**](https://epri-peac.com/solar-equipment/brands/miasole/) Registry: **CEC Verified Engineering Specification**

Miasole FLEX-03 290W is a 290.0 W STC (250.8 W PTC) CIGS solar module ranking #17,253 of 21,677 CEC listings (below all-CEC median; higher than 18.8% of peers). It delivers 13.12% efficiency, 47.2 V Voc at 25 C, and 53.06 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 290.0 W

- **PTC Wattage** : 250.8 W

- **Voc @ 25C** : 47.2 V

- **Efficiency** : 13.12%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Miasole FLEX-03 290W Compare Against Peer CEC Listings?

How Miasole Miasole FLEX-03 290W handles rooftop heat (250.8 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Miasole FLEX-03 290W exhibits 9.27 A short-circuit current, requiring a 14.46 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #17,253 of 21,677 (10.0 W below the 300.0 W CIGS median), this compact residential or specialty off-grid module covers 61.9 m2 for an 8 kW system (35 panels for 10 kW). Mid-range 47.2 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.

## Where Does Miasole FLEX-03 290W Fall Across Listed CEC Models?

Where Miasole FLEX-03 290W (290.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Miasole FLEX-03 290W?

Percentile placement of Miasole FLEX-03 290W across power density (131.2 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Miasole FLEX-03 290W?

Four critical engineering numbers homeowners and solar installers check first when reviewing Miasole FLEX-03 290W specifications. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Rank #17,253 / 21,677

### 290.0 W STC · Higher Than 18.8%

290.0 W STC (-95.0 W vs all-CEC median) vs 300.0 W CIGS median.

Eff #21,379

### 13.12% Aperture Efficiency

Power density 131.2 W/m2 (6.79 percentage points below 19.91% CEC median). PTC/STC ratio: 86.5% (rank #21,624).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.06 V at -10 C (583.7 V string) and 54.74 V at -20 C (10 max).

 8 kW Reference Array

### 28 Panels = 8,120 W STC

Occupies 61.9 m2 (666 sq ft) producing 7,022 W PTC; NEC 690.8 OCPD floor is 14.46 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 47.2 * (1 + (-0.355/100) * (-10 - 25)) = 53.06 V | OCPD = 1.56 * 9.27 = 14.46 A

Inputs from CEC Modules.csv for Miasole FLEX-03 290W: Voc=47.2 V, beta_Voc=-0.355%/C, Isc=9.27 A, STC=290.0 W, Area=2.211 m2.

**Result:** 11 panels max on 600 V (583.7 V); 28 panels for 8 kW (666 sq ft).

## What Are the Published CEC Specifications for Miasole FLEX-03 290W?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Miasole FLEX-03 290W.

Official California Energy Commission (NREL SAM) test parameters for Miasole FLEX-03 290W.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 290.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 250.8 W (86.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 47.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.27 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 37.2 V / 7.83 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.355 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 13.12% (2.211 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (CIGS) | Monofacial backsheet |

## How Many Miasole FLEX-03 290W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Miasole FLEX-03 290W (290.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 21 | 6.09 kW | 500 sq ft | $1,524 | $2,577 |
| **8 kW Class** | 28 | 8.12 kW | 666 sq ft | $2,032 | $3,437 |
| **10 kW Class** | 35 | 10.15 kW | 833 sq ft | $2,540 | $4,296 |

## How Many Miasole FLEX-03 290W Modules Fit in a Cold-Weather String?

Maximum series module counts for Miasole FLEX-03 290W from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=47.2V and beta_Voc=-0.355%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 54.74 V | 10 panels | 547.4 V | 18 panels |
| **-10 C (14 F)** | 53.06 V | 11 panels | 583.7 V | 18 panels |
| **0 C (32 F)** | 51.39 V | 11 panels | 565.3 V | 19 panels |
| **25 C (77 F STC)** | 47.2 V | 12 panels | 566.4 V | 21 panels |

## Which Cross-Brand Solar Modules Compare Closest to Miasole FLEX-03 290W?

Alternative CEC solar modules from competing brands near Miasole FLEX-03 290W (290.0 W), including AXITEC AC-290M/156-72S. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**AXITEC AC-290M/156-72S**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-290m-156-72s/) AXITEC | 290.0 W | Tie (0 W) | 44.98 V | 14.95% | 90.6% |
| [**Gintung Energy GTEC-290G6S**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-290g6s/) Gintung Energy | 290.0 W | Tie (0 W) | 44.84 V | 14.83% | 89.7% |
| [**Gintung Energy GTEC-290G6M**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-290g6m/) Gintung Energy | 290.0 W | Tie (0 W) | 44.61 V | 14.83% | 89.6% |
| [**Centrosolar America DM72 290**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dm72-290/) Centrosolar America | 290.0 W | Tie (0 W) | 44.4 V | 14.92% | 90.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Miasole FLEX-03 290W?

Evaluate Miasole FLEX-03 290W (290.0 W STC, 47.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Miasole FLEX-03 290W reaches 54.74 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 28 panels for an 8 kW build require 666 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (666 sq ft).
- 2026 tax credit baseline: cash residential installs of Miasole FLEX-03 290W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Miasole FLEX-03 290W 8 kW Residential Fit

Needs 28 modules (666 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare AXITEC AC-290M/156-72S.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 250.8 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Miasole FLEX-03 290W by Miasole grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Miasole FLEX-03 290W PTC wattage (250.8 W) lower than STC (290.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 250.8 W PTC (86.5% retention) across Miasole FLEX-03 290W's 2.211 m2 aperture.

### Who should skip Miasole FLEX-03 290W on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 28 Miasole FLEX-03 290W panels (666 sq ft) leave unusable roof gaps vs. AXITEC AC-290M/156-72S.

### What is the 1,000 V commercial string limit for Miasole FLEX-03 290W?

On 1,000 V commercial inverters at -10 C (53.06 V cold Voc), Miasole FLEX-03 290W fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Miasole FLEX-03 290W.

## Related Pages

Compare Miasole equipment, AXITEC AC-290M/156-72S specs, utility payback rates, and NEC string calculators alongside Miasole FLEX-03 290W.

[All Miasole Certified Solar Models](https://epri-peac.com/solar-equipment/brands/miasole/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Miasole

- [All Miasole Specs](https://epri-peac.com/solar-equipment/brands/miasole/)
- [Miasole FLEX-03 500W](https://epri-peac.com/solar-equipment/modules/miasole/miasole-flex-03-500w/)
- [Miasole FLEX-03 490W](https://epri-peac.com/solar-equipment/modules/miasole/miasole-flex-03-490w/)
- [Miasole FLEX-03 470W](https://epri-peac.com/solar-equipment/modules/miasole/miasole-flex-03-470w/)
- [Miasole FLEX-03 310W](https://epri-peac.com/solar-equipment/modules/miasole/miasole-flex-03-310w/)
- [Miasole FLEX-03 280NL](https://epri-peac.com/solar-equipment/modules/miasole/miasole-flex-03-280nl/)