title: "Merlin Solar Technologies Inc Specs (120.0W, 16.3V Voc)"
url: https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-rfp-f024w120l/
description: "CEC datasheet for Merlin Solar Technologies Inc RFP-F024W120L: 120.0W STC, 16.3V Voc, 67-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# Merlin Solar Technologies Inc RFP-F024W120L — CEC Solar Module Specifications

Manufacturer: [**Merlin Solar Technologies Inc**](https://epri-peac.com/solar-equipment/brands/merlin-solar-technologies-inc/) Registry: **CEC Verified Engineering Specification**

Merlin Solar Technologies Inc RFP-F024W120L is a 120.0 W STC (108.7 W PTC) Mono-c-Si solar module ranking #21,493 of 21,677 CEC listings (below all-CEC median; higher than 0.8% of peers). It delivers 15.79% efficiency, 16.3 V Voc at 25 C, and 17.79 V cold Voc at -10 C (33 panels max per 600 V string).

- **STC Wattage** : 120.0 W

- **PTC Wattage** : 108.7 W

- **Voc @ 25C** : 16.3 V

- **Efficiency** : 15.79%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Merlin Solar Technologies Inc RFP-F024W120L Compare Against Peer CEC Listings?

How Merlin Solar Technologies Inc Merlin Solar Technologies Inc RFP-F024W120L handles rooftop heat (108.7 W PTC), 8 kW sizing, and cold winter string voltage.

Merlin Solar Technologies Inc builds the Merlin Solar Technologies Inc RFP-F024W120L (Mono-c-Si) as a compact residential or specialty off-grid module delivering 157.9 W/m2 (4.12 percentage points below 19.91% CEC median). Compared against SunTegra STS-114M-B4U (114.0 W), this model holds typical 90.6% PTC-to-STC thermal output (108.7 W real-world rating). Lower 16.3 V string voltage fits 33 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 14.35 A overcurrent floor served by a 15 A breaker.

## Where Does Merlin Solar Technologies Inc RFP-F024W120L Fall Across Listed CEC Models?

Where Merlin Solar Technologies Inc RFP-F024W120L (120.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Merlin Solar Technologies Inc RFP-F024W120L?

Percentile placement of Merlin Solar Technologies Inc RFP-F024W120L across power density (157.9 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Merlin Solar Technologies Inc RFP-F024W120L?

Four critical engineering numbers homeowners and solar installers check first when reviewing Merlin Solar Technologies Inc RFP-F024W120L specifications.

Rank #21,493 / 21,677

### 120.0 W STC · Higher Than 0.8%

120.0 W STC (-265.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #18,445

### 15.79% Aperture Efficiency

Power density 157.9 W/m2 (4.12 percentage points below 19.91% CEC median). PTC/STC ratio: 90.6% (rank #17,534).

NEC 690.7 Limit

### 33 Panels Max @ -10 C (600 V)

Cold Voc reaches 17.79 V at -10 C (587.1 V string) and 18.22 V at -20 C (32 max).

 8 kW Reference Array

### 67 Panels = 8,040 W STC

Occupies 50.9 m2 (548 sq ft) producing 7,283 W PTC; NEC 690.8 OCPD floor is 14.35 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 16.3 * (1 + (-0.262/100) * (-10 - 25)) = 17.79 V | OCPD = 1.56 * 9.2 = 14.35 A

Inputs from CEC Modules.csv for Merlin Solar Technologies Inc RFP-F024W120L: Voc=16.3 V, beta_Voc=-0.262%/C, Isc=9.2 A, STC=120.0 W, Area=0.76 m2.

**Result:** 33 panels max on 600 V (587.1 V); 67 panels for 8 kW (548 sq ft).

## What Are the Published CEC Specifications for Merlin Solar Technologies Inc RFP-F024W120L?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Merlin Solar Technologies Inc RFP-F024W120L.

Official California Energy Commission (NREL SAM) test parameters for Merlin Solar Technologies Inc RFP-F024W120L.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 120.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 108.7 W (90.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 16.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.2 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 13.69 V / 8.77 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.262 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.79% (0.76 m2) | Array roof footprint density |
| **Cell Count & Technology** | 24 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Merlin Solar Technologies Inc RFP-F024W120L Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Merlin Solar Technologies Inc RFP-F024W120L (120.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 50 | 6.0 kW | 409 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 67 | 8.04 kW | 548 sq ft | $2,012 | $3,403 |
| **10 kW Class** | 84 | 10.08 kW | 687 sq ft | $2,523 | $4,266 |

## Which Sibling Wattage & Trim Variants Belong to This Merlin Solar Technologies Inc Series?

All closely matched Merlin Solar Technologies Inc wattages and cosmetic trims sharing the Merlin Solar Technologies Inc RFP-F024W120L architecture.

Sibling CEC listings grouped into the Merlin Solar Technologies Inc RFP-F024W120L wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Merlin Solar Technologies Inc RFP-F024W117L** | 117.0 W | 105.9 W | 16.25 V | 13.49 V | 15.39% |
| **Merlin Solar Technologies Inc RFP-F024W120L** | 120.0 W | 108.7 W | 16.3 V | 13.69 V | 15.79% |
| **Merlin Solar Technologies Inc RFP-F024W123L** | 123.0 W | 111.5 W | 16.35 V | 13.89 V | 16.18% |

## How Many Merlin Solar Technologies Inc RFP-F024W120L Modules Fit in a Cold-Weather String?

Maximum series module counts for Merlin Solar Technologies Inc RFP-F024W120L from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=16.3V and beta_Voc=-0.262%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 18.22 V | 32 panels | 583.0 V | 54 panels |
| **-10 C (14 F)** | 17.79 V | 33 panels | 587.1 V | 56 panels |
| **0 C (32 F)** | 17.37 V | 34 panels | 590.6 V | 57 panels |
| **25 C (77 F STC)** | 16.3 V | 36 panels | 586.8 V | 61 panels |

## Which Cross-Brand Solar Modules Compare Closest to Merlin Solar Technologies Inc RFP-F024W120L?

Alternative CEC solar modules from competing brands near Merlin Solar Technologies Inc RFP-F024W120L (120.0 W), including SunTegra STS-114M-B4U.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**SunTegra STS-114M-B4U**](https://epri-peac.com/solar-equipment/modules/suntegra/suntegra-sts-114m-b4u/) SunTegra | 114.0 W | -6.0 W | 15.52 V | 17.27% | 86.8% |
| [**SunStyle M110 870**](https://epri-peac.com/solar-equipment/modules/sunstyle/sunstyle-m110-870/) SunStyle | 110.0 W | -10.0 W | 16.1 V | 14.47% | 89.3% |
| [**Solar Frame Solutions Inc SFS135T**](https://epri-peac.com/solar-equipment/modules/solar-frame-solutions-inc/solar-frame-solutions-inc-sfs135t/) Solar Frame Solutions Inc | 135.0 W | +15.0 W | 16.4 V | 16.46% | 92.1% |
| [**WAAREE ENERGIES LIMITED WU-120**](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-wu-120/) WAAREE ENERGIES LIMITED | 120.0 W | Tie (0 W) | 21.0 V | 12.2% | 88.7% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Merlin Solar Technologies Inc RFP-F024W120L?

Evaluate Merlin Solar Technologies Inc RFP-F024W120L (120.0 W STC, 16.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Merlin Solar Technologies Inc RFP-F024W120L reaches 18.22 V per panel—exceeding 32 panels in series voids 600 V inverter warranties.
- Footprint constraint: 67 panels for an 8 kW build require 548 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 67 panels (548 sq ft).
- 2026 tax credit baseline: cash residential installs of Merlin Solar Technologies Inc RFP-F024W120L carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Merlin Solar Technologies Inc RFP-F024W120L 8 kW Residential Fit

Needs 67 modules (548 sq ft) with a 15 A string OCPD, offsetting ~$2,012/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 33 panels (-10 C) or 32 panels (-20 C), or compare SunTegra STS-114M-B4U.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 108.7 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Merlin Solar Technologies Inc RFP-F024W120L by Merlin Solar Technologies Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Merlin Solar Technologies Inc RFP-F024W120L?

Multiplying Merlin Solar Technologies Inc RFP-F024W120L's 9.2 A short-circuit current by 1.56 equals 14.35 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can Merlin Solar Technologies Inc RFP-F024W120L pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 17.79 V cold Voc at 14 F and handles 9.2 A Isc; string inverters cap Merlin Solar Technologies Inc RFP-F024W120L at 33 panels on 600 V.

### Is Merlin Solar Technologies Inc RFP-F024W120L eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Merlin Solar Technologies Inc RFP-F024W120L rely on utility bill offset (~$2,012/yr at 8 kW) rather than 25D.

## Related Pages

Compare Merlin Solar Technologies Inc equipment, SunTegra STS-114M-B4U specs, utility payback rates, and NEC string calculators alongside Merlin Solar Technologies Inc RFP-F024W120L.

[All Merlin Solar Technologies Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/merlin-solar-technologies-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Merlin Solar Technologies Inc

- [All Merlin Solar Technologies Inc Specs](https://epri-peac.com/solar-equipment/brands/merlin-solar-technologies-inc/)
- [Merlin Solar Technologies Inc BR335](https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-br335/)
- [Merlin Solar Technologies Inc BR320](https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-br320/)
- [Merlin Solar Technologies Inc RFP-F036B180L](https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-rfp-f036b180l/)
- [Merlin Solar Technologies Inc RFP-F036B180S](https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-rfp-f036b180s/)
- [Merlin Solar Technologies Inc RFP-F036W180L](https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-rfp-f036w180l/)