title: "Merlin Solar Technologies Inc Specs (165.0W, 23.1V Voc)"
url: https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-gx165/
description: "CEC datasheet for Merlin Solar Technologies Inc GX165: 165.0W STC, 23.1V Voc, 49-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Merlin Solar Technologies Inc GX165 — CEC Solar Module Specifications

Manufacturer: [**Merlin Solar Technologies Inc**](https://epri-peac.com/solar-equipment/brands/merlin-solar-technologies-inc/) Registry: **CEC Verified Engineering Specification**

Merlin Solar Technologies Inc GX165 is a 165.0 W STC (145.8 W PTC) Mono-c-Si solar module ranking #21,351 of 21,677 CEC listings (below all-CEC median; higher than 1.4% of peers). It delivers 16.32% efficiency, 23.1 V Voc at 25 C, and 25.78 V cold Voc at -10 C (23 panels max per 600 V string).

- **STC Wattage** : 165.0 W

- **PTC Wattage** : 145.8 W

- **Voc @ 25C** : 23.1 V

- **Efficiency** : 16.32%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Merlin Solar Technologies Inc GX165 Compare Against Peer CEC Listings?

How Merlin Solar Technologies Inc Merlin Solar Technologies Inc GX165 handles rooftop heat (145.8 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Merlin Solar Technologies Inc GX165 exhibits 9.05 A short-circuit current, requiring a 14.12 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #21,351 of 21,677 (245.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 49.5 m2 for an 8 kW system (61 panels for 10 kW). Lower 23.1 V string voltage fits 23 panels in series at 14 F and pairs easily with microinverters.

## Where Does Merlin Solar Technologies Inc GX165 Fall Across Listed CEC Models?

Where Merlin Solar Technologies Inc GX165 (165.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Merlin Solar Technologies Inc GX165?

Percentile placement of Merlin Solar Technologies Inc GX165 across power density (163.2 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Merlin Solar Technologies Inc GX165?

Four critical engineering numbers homeowners and solar installers check first when reviewing Merlin Solar Technologies Inc GX165 specifications.

Rank #21,351 / 21,677

### 165.0 W STC · Higher Than 1.4%

165.0 W STC (-220.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #17,631

### 16.32% Aperture Efficiency

Power density 163.2 W/m2 (3.59 percentage points below 19.91% CEC median). PTC/STC ratio: 88.4% (rank #21,190).

NEC 690.7 Limit

### 23 Panels Max @ -10 C (600 V)

Cold Voc reaches 25.78 V at -10 C (592.9 V string) and 26.55 V at -20 C (22 max).

 8 kW Reference Array

### 49 Panels = 8,085 W STC

Occupies 49.5 m2 (533 sq ft) producing 7,144 W PTC; NEC 690.8 OCPD floor is 14.12 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 23.1 * (1 + (-0.332/100) * (-10 - 25)) = 25.78 V | OCPD = 1.56 * 9.05 = 14.12 A

Inputs from CEC Modules.csv for Merlin Solar Technologies Inc GX165: Voc=23.1 V, beta_Voc=-0.332%/C, Isc=9.05 A, STC=165.0 W, Area=1.011 m2.

**Result:** 23 panels max on 600 V (592.9 V); 49 panels for 8 kW (533 sq ft).

## What Are the Published CEC Specifications for Merlin Solar Technologies Inc GX165?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Merlin Solar Technologies Inc GX165.

Official California Energy Commission (NREL SAM) test parameters for Merlin Solar Technologies Inc GX165.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 165.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 145.8 W (88.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 23.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.05 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 18.95 V / 8.74 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.332 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 16.32% (1.011 m2) | Array roof footprint density |
| **Cell Count & Technology** | 36 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Merlin Solar Technologies Inc GX165 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Merlin Solar Technologies Inc GX165 (165.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 37 | 6.11 kW | 403 sq ft | $1,529 | $2,586 |
| **8 kW Class** | 49 | 8.09 kW | 533 sq ft | $2,025 | $3,424 |
| **10 kW Class** | 61 | 10.06 kW | 664 sq ft | $2,518 | $4,258 |

## Which Sibling Wattage & Trim Variants Belong to This Merlin Solar Technologies Inc Series?

All closely matched Merlin Solar Technologies Inc wattages and cosmetic trims sharing the Merlin Solar Technologies Inc GX165 architecture.

Sibling CEC listings grouped into the Merlin Solar Technologies Inc GX165 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Merlin Solar Technologies Inc GX160** | 160.0 W | 141.3 W | 22.85 V | 18.7 V | 15.83% |
| **Merlin Solar Technologies Inc GX165** | 165.0 W | 145.8 W | 23.1 V | 18.95 V | 16.32% |
| **Merlin Solar Technologies Inc GX170** | 170.0 W | 150.4 W | 23.4 V | 19.15 V | 16.82% |

## How Many Merlin Solar Technologies Inc GX165 Modules Fit in a Cold-Weather String?

Maximum series module counts for Merlin Solar Technologies Inc GX165 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=23.1V and beta_Voc=-0.332%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 26.55 V | 22 panels | 584.1 V | 37 panels |
| **-10 C (14 F)** | 25.78 V | 23 panels | 592.9 V | 38 panels |
| **0 C (32 F)** | 25.02 V | 23 panels | 575.5 V | 39 panels |
| **25 C (77 F STC)** | 23.1 V | 25 panels | 577.5 V | 43 panels |

## Which Cross-Brand Solar Modules Compare Closest to Merlin Solar Technologies Inc GX165?

Alternative CEC solar modules from competing brands near Merlin Solar Technologies Inc GX165 (165.0 W), including Walters & Wolf Glass Co VL-A200-1-0804-160W-M.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Walters & Wolf Glass Co VL-A200-1-0804-160W-M**](https://epri-peac.com/solar-equipment/modules/walters-wolf-glass-co/walters-wolf-glass-co-vl-a200-1-0804-160w-m/) Walters & Wolf Glass Co | 160.0 W | -5.0 W | 22.13 V | 15.53% | 92.9% |
| [**Auxin Solar AXN6M409T155**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn6m409t155/) Auxin Solar | 155.0 W | -10.0 W | 22.68 V | 15.82% | 89.5% |
| [**Gintung Energy ASEC-155G6S49**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-155g6s49/) Gintung Energy | 155.0 W | -10.0 W | 22.58 V | 15.71% | 87.7% |
| [**Trina Solar TSM-160PEG4007**](https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-160peg4007/) Trina Solar | 160.0 W | -5.0 W | 24.9 V | 9.73% | 87.9% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Merlin Solar Technologies Inc GX165?

Evaluate Merlin Solar Technologies Inc GX165 (165.0 W STC, 23.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Merlin Solar Technologies Inc GX165 reaches 26.55 V per panel—exceeding 22 panels in series voids 600 V inverter warranties.
- Footprint constraint: 49 panels for an 8 kW build require 533 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 49 panels (533 sq ft).
- 2026 tax credit baseline: cash residential installs of Merlin Solar Technologies Inc GX165 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Merlin Solar Technologies Inc GX165 8 kW Residential Fit

Needs 49 modules (533 sq ft) with a 15 A string OCPD, offsetting ~$2,025/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 23 panels (-10 C) or 22 panels (-20 C), or compare Walters & Wolf Glass Co VL-A200-1-0804-160W-M.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 145.8 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Merlin Solar Technologies Inc GX165 by Merlin Solar Technologies Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Merlin Solar Technologies Inc GX165 PTC wattage (145.8 W) lower than STC (165.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 145.8 W PTC (88.4% retention) across Merlin Solar Technologies Inc GX165's 1.011 m2 aperture.

### Who should skip Merlin Solar Technologies Inc GX165 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 49 Merlin Solar Technologies Inc GX165 panels (533 sq ft) leave unusable roof gaps vs. Walters & Wolf Glass Co VL-A200-1-0804-160W-M.

### What is the 1,000 V commercial string limit for Merlin Solar Technologies Inc GX165?

On 1,000 V commercial inverters at -10 C (25.78 V cold Voc), Merlin Solar Technologies Inc GX165 fits up to 38 panels per series string.

## Related Pages

Compare Merlin Solar Technologies Inc equipment, Walters & Wolf Glass Co VL-A200-1-0804-160W-M specs, utility payback rates, and NEC string calculators alongside Merlin Solar Technologies Inc GX165.

[All Merlin Solar Technologies Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/merlin-solar-technologies-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Merlin Solar Technologies Inc

- [All Merlin Solar Technologies Inc Specs](https://epri-peac.com/solar-equipment/brands/merlin-solar-technologies-inc/)
- [Merlin Solar Technologies Inc BR335](https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-br335/)
- [Merlin Solar Technologies Inc BR320](https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-br320/)
- [Merlin Solar Technologies Inc RFP-F036B180L](https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-rfp-f036b180l/)
- [Merlin Solar Technologies Inc RFP-F036B180S](https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-rfp-f036b180s/)
- [Merlin Solar Technologies Inc RFP-F036W180L](https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-rfp-f036w180l/)