title: "Merlin Solar Technologies Inc FXS Specs (95.0W, 15.08V Voc)"
url: https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-fxs-95-b/
description: "CEC datasheet for Merlin Solar Technologies Inc FXS 95-B: 95.0W STC, 15.08V Voc, 85-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Merlin Solar Technologies Inc FXS 95-B — CEC Solar Module Specifications

Manufacturer: [**Merlin Solar Technologies Inc**](https://epri-peac.com/solar-equipment/brands/merlin-solar-technologies-inc/) Registry: **CEC Verified Engineering Specification**

Merlin Solar Technologies Inc FXS 95-B is a 95.0 W STC (83.8 W PTC) Mono-c-Si solar module ranking #21,579 of 21,677 CEC listings (below all-CEC median; higher than 0.4% of peers). It delivers 12.67% efficiency, 15.08 V Voc at 25 C, and 16.72 V cold Voc at -10 C (35 panels max per 600 V string).

- **STC Wattage** : 95.0 W

- **PTC Wattage** : 83.8 W

- **Voc @ 25C** : 15.08 V

- **Efficiency** : 12.67%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Merlin Solar Technologies Inc FXS 95-B Compare Against Peer CEC Listings?

How Merlin Solar Technologies Inc Merlin Solar Technologies Inc FXS 95-B handles rooftop heat (83.8 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Merlin Solar Technologies Inc FXS 95-B exhibits 8.46 A short-circuit current, requiring a 13.2 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #21,579 of 21,677 (315.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 63.8 m2 for an 8 kW system (106 panels for 10 kW). Lower 15.08 V string voltage fits 35 panels in series at 14 F and pairs easily with microinverters.

## Where Does Merlin Solar Technologies Inc FXS 95-B Fall Across Listed CEC Models?

Where Merlin Solar Technologies Inc FXS 95-B (95.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Merlin Solar Technologies Inc FXS 95-B?

Percentile placement of Merlin Solar Technologies Inc FXS 95-B across power density (126.7 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Merlin Solar Technologies Inc FXS 95-B?

Four critical engineering numbers homeowners and solar installers check first when reviewing Merlin Solar Technologies Inc FXS 95-B specifications.

Rank #21,579 / 21,677

### 95.0 W STC · Higher Than 0.4%

95.0 W STC (-290.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #21,496

### 12.67% Aperture Efficiency

Power density 126.7 W/m2 (7.24 percentage points below 19.91% CEC median). PTC/STC ratio: 88.2% (rank #21,309).

NEC 690.7 Limit

### 35 Panels Max @ -10 C (600 V)

Cold Voc reaches 16.72 V at -10 C (585.2 V string) and 17.18 V at -20 C (34 max).

 8 kW Reference Array

### 85 Panels = 8,075 W STC

Occupies 63.8 m2 (686 sq ft) producing 7,123 W PTC; NEC 690.8 OCPD floor is 13.2 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 15.08 * (1 + (-0.31/100) * (-10 - 25)) = 16.72 V | OCPD = 1.56 * 8.46 = 13.2 A

Inputs from CEC Modules.csv for Merlin Solar Technologies Inc FXS 95-B: Voc=15.08 V, beta_Voc=-0.31%/C, Isc=8.46 A, STC=95.0 W, Area=0.75 m2.

**Result:** 35 panels max on 600 V (585.2 V); 85 panels for 8 kW (686 sq ft).

## What Are the Published CEC Specifications for Merlin Solar Technologies Inc FXS 95-B?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Merlin Solar Technologies Inc FXS 95-B.

Official California Energy Commission (NREL SAM) test parameters for Merlin Solar Technologies Inc FXS 95-B.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 95.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 83.8 W (88.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 15.08 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.46 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 11.84 V / 8.1 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.31 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 12.67% (0.75 m2) | Array roof footprint density |
| **Cell Count & Technology** | 24 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Merlin Solar Technologies Inc FXS 95-B Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Merlin Solar Technologies Inc FXS 95-B (95.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 64 | 6.08 kW | 517 sq ft | $1,522 | $2,573 |
| **8 kW Class** | 85 | 8.07 kW | 686 sq ft | $2,020 | $3,415 |
| **10 kW Class** | 106 | 10.07 kW | 856 sq ft | $2,520 | $4,262 |

## How Many Merlin Solar Technologies Inc FXS 95-B Modules Fit in a Cold-Weather String?

Maximum series module counts for Merlin Solar Technologies Inc FXS 95-B from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=15.08V and beta_Voc=-0.31%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 17.18 V | 34 panels | 584.1 V | 58 panels |
| **-10 C (14 F)** | 16.72 V | 35 panels | 585.2 V | 59 panels |
| **0 C (32 F)** | 16.25 V | 36 panels | 585.0 V | 61 panels |
| **25 C (77 F STC)** | 15.08 V | 39 panels | 588.1 V | 66 panels |

## Which Cross-Brand Solar Modules Compare Closest to Merlin Solar Technologies Inc FXS 95-B?

Alternative CEC solar modules from competing brands near Merlin Solar Technologies Inc FXS 95-B (95.0 W), including Heliene 20M-100GH.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Heliene 20M-100GH**](https://epri-peac.com/solar-equipment/modules/heliene/heliene-20m-100gh/) Heliene | 100.0 W | +5.0 W | 13.3 V | 6.17% | 85.2% |
| [**SUNSTYLE AG / LTD SUNSTYLE M80**](https://epri-peac.com/solar-equipment/modules/sunstyle-ag-ltd/sunstyle-ag-ltd-sunstyle-m80/) SUNSTYLE AG / LTD | 80.0 W | -15.0 W | 15.7 V | 11.19% | 91.0% |
| [**SunStyle M110 870**](https://epri-peac.com/solar-equipment/modules/sunstyle/sunstyle-m110-870/) SunStyle | 110.0 W | +15.0 W | 16.1 V | 14.47% | 89.3% |
| [**SunTegra STS-114M-B4U**](https://epri-peac.com/solar-equipment/modules/suntegra/suntegra-sts-114m-b4u/) SunTegra | 114.0 W | +19.0 W | 15.52 V | 17.27% | 86.8% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Merlin Solar Technologies Inc FXS 95-B?

Evaluate Merlin Solar Technologies Inc FXS 95-B (95.0 W STC, 15.08 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Merlin Solar Technologies Inc FXS 95-B reaches 17.18 V per panel—exceeding 34 panels in series voids 600 V inverter warranties.
- Footprint constraint: 85 panels for an 8 kW build require 686 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 85 panels (686 sq ft).
- 2026 tax credit baseline: cash residential installs of Merlin Solar Technologies Inc FXS 95-B carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Merlin Solar Technologies Inc FXS 95-B 8 kW Residential Fit

Needs 85 modules (686 sq ft) with a 15 A string OCPD, offsetting ~$2,020/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 35 panels (-10 C) or 34 panels (-20 C), or compare Heliene 20M-100GH.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 83.8 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Merlin Solar Technologies Inc FXS 95-B by Merlin Solar Technologies Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Merlin Solar Technologies Inc FXS 95-B PTC wattage (83.8 W) lower than STC (95.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 83.8 W PTC (88.2% retention) across Merlin Solar Technologies Inc FXS 95-B's 0.75 m2 aperture.

### Who should skip Merlin Solar Technologies Inc FXS 95-B on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 85 Merlin Solar Technologies Inc FXS 95-B panels (686 sq ft) leave unusable roof gaps vs. Heliene 20M-100GH.

### What is the 1,000 V commercial string limit for Merlin Solar Technologies Inc FXS 95-B?

On 1,000 V commercial inverters at -10 C (16.72 V cold Voc), Merlin Solar Technologies Inc FXS 95-B fits up to 59 panels per series string.

## Related Pages

Compare Merlin Solar Technologies Inc equipment, Heliene 20M-100GH specs, utility payback rates, and NEC string calculators alongside Merlin Solar Technologies Inc FXS 95-B.

[All Merlin Solar Technologies Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/merlin-solar-technologies-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Merlin Solar Technologies Inc

- [All Merlin Solar Technologies Inc Specs](https://epri-peac.com/solar-equipment/brands/merlin-solar-technologies-inc/)
- [Merlin Solar Technologies Inc BR335](https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-br335/)
- [Merlin Solar Technologies Inc BR320](https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-br320/)
- [Merlin Solar Technologies Inc RFP-F036B180L](https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-rfp-f036b180l/)
- [Merlin Solar Technologies Inc RFP-F036B180S](https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-rfp-f036b180s/)
- [Merlin Solar Technologies Inc RFP-F036W180L](https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-rfp-f036w180l/)