title: "Maxeon Solar Technologies Ltd Specs (400.0W, 75.4V Voc)"
url: https://epri-peac.com/solar-equipment/modules/maxeon-solar-technologies-ltd/maxeon-solar-technologies-ltd-spr-max3-400-com/
description: "CEC datasheet for Maxeon Solar Technologies Ltd SPR-MAX3-400-COM: 400.0W STC, 75.4V Voc, 20-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# Maxeon Solar Technologies Ltd SPR-MAX3-400-COM — CEC Solar Module Specifications

Manufacturer: [**Maxeon Solar Technologies Ltd**](https://epri-peac.com/solar-equipment/brands/maxeon-solar-technologies-ltd/) Registry: **CEC Verified Engineering Specification**

Maxeon Solar Technologies Ltd SPR-MAX3-400-COM is a 400.0 W STC (372.4 W PTC) Mono-c-Si solar module ranking #9,407 of 21,677 CEC listings (top 45.5%; higher than 54.5% of peers). It delivers 22.6% efficiency, 75.4 V Voc at 25 C, and 81.42 V cold Voc at -10 C (7 panels max per 600 V string).

- **STC Wattage** : 400.0 W

- **PTC Wattage** : 372.4 W

- **Voc @ 25C** : 75.4 V

- **Efficiency** : 22.6%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Maxeon Solar Technologies Ltd SPR-MAX3-400-COM Compare Against Peer CEC Listings?

How Maxeon Solar Technologies Ltd Maxeon Solar Technologies Ltd SPR-MAX3-400-COM handles rooftop heat (372.4 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Maxeon Solar Technologies Ltd SPR-MAX3-400-COM exhibits 6.57 A short-circuit current, requiring a 10.25 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #9,407 of 21,677 (10.0 W below the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 35.4 m2 for an 8 kW system (25 panels for 10 kW). Higher 75.4 V open-circuit voltage caps 600 V residential strings at 7 panels at 14 F (-10 C).

## Where Does Maxeon Solar Technologies Ltd SPR-MAX3-400-COM Fall Across Listed CEC Models?

Where Maxeon Solar Technologies Ltd SPR-MAX3-400-COM (400.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Maxeon Solar Technologies Ltd SPR-MAX3-400-COM?

Percentile placement of Maxeon Solar Technologies Ltd SPR-MAX3-400-COM across power density (226.0 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Maxeon Solar Technologies Ltd SPR-MAX3-400-COM?

Four critical engineering numbers homeowners and solar installers check first when reviewing Maxeon Solar Technologies Ltd SPR-MAX3-400-COM specifications.

Rank #9,407 / 21,677

### Top 45.5% STC Output

400.0 W STC (+15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,830

### 22.6% Aperture Efficiency

Power density 226.0 W/m2 (2.69 percentage points above 19.91% CEC median). PTC/STC ratio: 93.1% (rank #9,420).

NEC 690.7 Limit

### 7 Panels Max @ -10 C (600 V)

Cold Voc reaches 81.42 V at -10 C (569.9 V string) and 83.14 V at -20 C (7 max).

 8 kW Reference Array

### 20 Panels = 8,000 W STC

Occupies 35.4 m2 (381 sq ft) producing 7,448 W PTC; NEC 690.8 OCPD floor is 10.25 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 75.4 * (1 + (-0.228/100) * (-10 - 25)) = 81.42 V | OCPD = 1.56 * 6.57 = 10.25 A

Inputs from CEC Modules.csv for Maxeon Solar Technologies Ltd SPR-MAX3-400-COM: Voc=75.4 V, beta_Voc=-0.228%/C, Isc=6.57 A, STC=400.0 W, Area=1.77 m2.

**Result:** 7 panels max on 600 V (569.9 V); 20 panels for 8 kW (381 sq ft).

## What Are the Published CEC Specifications for Maxeon Solar Technologies Ltd SPR-MAX3-400-COM?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Maxeon Solar Technologies Ltd SPR-MAX3-400-COM.

Official California Energy Commission (NREL SAM) test parameters for Maxeon Solar Technologies Ltd SPR-MAX3-400-COM.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 400.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 372.4 W (93.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 75.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 6.57 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 66.0 V / 6.07 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.228 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 22.6% (1.77 m2) | Array roof footprint density |
| **Cell Count & Technology** | 104 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Maxeon Solar Technologies Ltd SPR-MAX3-400-COM Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Maxeon Solar Technologies Ltd SPR-MAX3-400-COM (400.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 15 | 6.0 kW | 286 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 20 | 8.0 kW | 381 sq ft | $2,002 | $3,386 |
| **10 kW Class** | 25 | 10.0 kW | 476 sq ft | $2,503 | $4,232 |

## How Many Maxeon Solar Technologies Ltd SPR-MAX3-400-COM Modules Fit in a Cold-Weather String?

Maximum series module counts for Maxeon Solar Technologies Ltd SPR-MAX3-400-COM from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=75.4V and beta_Voc=-0.228%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 83.14 V | 7 panels | 582.0 V | 12 panels |
| **-10 C (14 F)** | 81.42 V | 7 panels | 569.9 V | 12 panels |
| **0 C (32 F)** | 79.7 V | 7 panels | 557.9 V | 12 panels |
| **25 C (77 F STC)** | 75.4 V | 7 panels | 527.8 V | 13 panels |

## Which Cross-Brand Solar Modules Compare Closest to Maxeon Solar Technologies Ltd SPR-MAX3-400-COM?

Alternative CEC solar modules from competing brands near Maxeon Solar Technologies Ltd SPR-MAX3-400-COM (400.0 W), including CSI Solar Co Ltd CS1Y-410MS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS1Y-410MS**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs1y-410ms/) CSI Solar Co Ltd | 410.0 W | +10.0 W | 52.7 V | 21.03% | 94.1% |
| [**Boviet Solar Technology Co Ltd BVM6612M-400-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-400-h/) Boviet Solar Technology Co Ltd | 400.0 W | Tie (0 W) | 49.2 V | 20.62% | 93.2% |
| [**Boviet Solar Technology Co Ltd BVM6612M-W5-400-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-w5-400-h/) Boviet Solar Technology Co Ltd | 400.0 W | Tie (0 W) | 49.2 V | 20.62% | 93.2% |
| [**Boviet Solar Technology Co Ltd BVM6612M-405L-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-405l-h/) Boviet Solar Technology Co Ltd | 405.0 W | +5.0 W | 49.45 V | 20.35% | 93.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Maxeon Solar Technologies Ltd SPR-MAX3-400-COM?

Evaluate Maxeon Solar Technologies Ltd SPR-MAX3-400-COM (400.0 W STC, 75.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Maxeon Solar Technologies Ltd SPR-MAX3-400-COM reaches 83.14 V per panel—exceeding 7 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 381 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (381 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Maxeon Solar Technologies Ltd SPR-MAX3-400-COM carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Maxeon Solar Technologies Ltd SPR-MAX3-400-COM 8 kW Residential Fit

Needs 20 modules (381 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 7 panels (-10 C) or 7 panels (-20 C), or compare CSI Solar Co Ltd CS1Y-410MS.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 372.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Maxeon Solar Technologies Ltd SPR-MAX3-400-COM by Maxeon Solar Technologies Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Maxeon Solar Technologies Ltd SPR-MAX3-400-COM PTC wattage (372.4 W) lower than STC (400.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 372.4 W PTC (93.1% retention) across Maxeon Solar Technologies Ltd SPR-MAX3-400-COM's 1.77 m2 aperture.

### Who should skip Maxeon Solar Technologies Ltd SPR-MAX3-400-COM on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 Maxeon Solar Technologies Ltd SPR-MAX3-400-COM panels (381 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS1Y-410MS.

### What is the 1,000 V commercial string limit for Maxeon Solar Technologies Ltd SPR-MAX3-400-COM?

On 1,000 V commercial inverters at -10 C (81.42 V cold Voc), Maxeon Solar Technologies Ltd SPR-MAX3-400-COM fits up to 12 panels per series string.

## Related Pages

Compare Maxeon Solar Technologies Ltd equipment, CSI Solar Co Ltd CS1Y-410MS specs, utility payback rates, and NEC string calculators alongside Maxeon Solar Technologies Ltd SPR-MAX3-400-COM.

[All Maxeon Solar Technologies Ltd Certified Solar Models](https://epri-peac.com/solar-equipment/brands/maxeon-solar-technologies-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Maxeon Solar Technologies Ltd

- [All Maxeon Solar Technologies Ltd Specs](https://epri-peac.com/solar-equipment/brands/maxeon-solar-technologies-ltd/)
- [Maxeon Solar Technologies Ltd SPR-P5-550-UPP](https://epri-peac.com/solar-equipment/modules/maxeon-solar-technologies-ltd/maxeon-solar-technologies-ltd-spr-p5-550-upp/)
- [Maxeon Solar Technologies Ltd SPR-P5-535-UPP](https://epri-peac.com/solar-equipment/modules/maxeon-solar-technologies-ltd/maxeon-solar-technologies-ltd-spr-p5-535-upp/)
- [Maxeon Solar Technologies Ltd SPR-P5-510-UPP](https://epri-peac.com/solar-equipment/modules/maxeon-solar-technologies-ltd/maxeon-solar-technologies-ltd-spr-p5-510-upp/)
- [Maxeon Solar Technologies Ltd SPR-P5-495-UPP](https://epri-peac.com/solar-equipment/modules/maxeon-solar-technologies-ltd/maxeon-solar-technologies-ltd-spr-p5-495-upp/)
- [Maxeon Solar Technologies Ltd SPR-MAX6-480-COM](https://epri-peac.com/solar-equipment/modules/maxeon-solar-technologies-ltd/maxeon-solar-technologies-ltd-spr-max6-480-com/)