title: "Lumos S48-270-29-IM Specs (270.0W, 32.5V Voc)"
url: https://epri-peac.com/solar-equipment/modules/lumos/lumos-s48-270-29-im/
description: "CEC datasheet for Lumos S48-270-29-IM: 270.0W STC, 32.5V Voc, 30-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Lumos S48-270-29-IM — CEC Solar Module Specifications

Manufacturer: [**Lumos**](https://epri-peac.com/solar-equipment/brands/lumos/) Registry: **CEC Verified Engineering Specification**

Lumos S48-270-29-IM is a 270.0 W STC (250.2 W PTC) Mono-c-Si solar module ranking #18,572 of 21,677 CEC listings (below all-CEC median; higher than 12.9% of peers). It delivers 13.99% efficiency, 32.5 V Voc at 25 C, and 36.19 V cold Voc at -10 C (16 panels max per 600 V string).

- **STC Wattage** : 270.0 W

- **PTC Wattage** : 250.2 W

- **Voc @ 25C** : 32.5 V

- **Efficiency** : 13.99%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Lumos S48-270-29-IM Compare Against Peer CEC Listings?

How Lumos Lumos S48-270-29-IM handles rooftop heat (250.2 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Lumos S48-270-29-IM exhibits 11.1 A short-circuit current, requiring a 17.32 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #18,572 of 21,677 (140.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 57.9 m2 for an 8 kW system (38 panels for 10 kW). Lower 32.5 V string voltage fits 16 panels in series at 14 F and pairs easily with microinverters.

## Where Does Lumos S48-270-29-IM Fall Across Listed CEC Models?

Where Lumos S48-270-29-IM (270.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Lumos S48-270-29-IM?

Percentile placement of Lumos S48-270-29-IM across power density (139.9 W/m2), thermal retention, and nameplate STC wattage. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

## What Do the Dataset Ranks Show for Lumos S48-270-29-IM?

Four critical engineering numbers homeowners and solar installers check first when reviewing Lumos S48-270-29-IM specifications. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Rank #18,572 / 21,677

### 270.0 W STC · Higher Than 12.9%

270.0 W STC (-115.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #20,904

### 13.99% Aperture Efficiency

Power density 139.9 W/m2 (5.92 percentage points below 19.91% CEC median). PTC/STC ratio: 92.7% (rank #11,468).

NEC 690.7 Limit

### 16 Panels Max @ -10 C (600 V)

Cold Voc reaches 36.19 V at -10 C (579.0 V string) and 37.24 V at -20 C (16 max).

 8 kW Reference Array

### 30 Panels = 8,100 W STC

Occupies 57.9 m2 (623 sq ft) producing 7,506 W PTC; NEC 690.8 OCPD floor is 17.32 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 32.5 * (1 + (-0.324/100) * (-10 - 25)) = 36.19 V | OCPD = 1.56 * 11.1 = 17.32 A

Inputs from CEC Modules.csv for Lumos S48-270-29-IM: Voc=32.5 V, beta_Voc=-0.324%/C, Isc=11.1 A, STC=270.0 W, Area=1.93 m2.

**Result:** 16 panels max on 600 V (579.0 V); 30 panels for 8 kW (623 sq ft).

## What Are the Published CEC Specifications for Lumos S48-270-29-IM?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Lumos S48-270-29-IM. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Official California Energy Commission (NREL SAM) test parameters for Lumos S48-270-29-IM.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 270.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 250.2 W (92.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 32.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 11.1 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 26.23 V / 10.48 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.324 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 13.99% (1.93 m2) | Array roof footprint density |
| **Cell Count & Technology** | 48 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Lumos S48-270-29-IM Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Lumos S48-270-29-IM (270.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 23 | 6.21 kW | 478 sq ft | $1,554 | $2,628 |
| **8 kW Class** | 30 | 8.1 kW | 623 sq ft | $2,027 | $3,428 |
| **10 kW Class** | 38 | 10.26 kW | 789 sq ft | $2,568 | $4,342 |

## How Many Lumos S48-270-29-IM Modules Fit in a Cold-Weather String?

Maximum series module counts for Lumos S48-270-29-IM from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=32.5V and beta_Voc=-0.324%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 37.24 V | 16 panels | 595.8 V | 26 panels |
| **-10 C (14 F)** | 36.19 V | 16 panels | 579.0 V | 27 panels |
| **0 C (32 F)** | 35.13 V | 17 panels | 597.2 V | 28 panels |
| **25 C (77 F STC)** | 32.5 V | 18 panels | 585.0 V | 30 panels |

## Which Cross-Brand Solar Modules Compare Closest to Lumos S48-270-29-IM?

Alternative CEC solar modules from competing brands near Lumos S48-270-29-IM (270.0 W), including CSI Solar Co Ltd CS6PH-260P.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS6PH-260P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6ph-260p/) CSI Solar Co Ltd | 260.0 W | -10.0 W | 34.6 V | 16.77% | 92.8% |
| [**Auxin Solar AXN6M610B295**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn6m610b295/) Auxin Solar | 295.0 W | +25.0 W | 40.11 V | 17.85% | 92.9% |
| [**CSI Solar Co Ltd CS6PH-280P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6ph-280p/) CSI Solar Co Ltd | 280.0 W | +10.0 W | 35.4 V | 18.06% | 93.0% |
| [**GermanSolar USA Inc GSP-270W**](https://epri-peac.com/solar-equipment/modules/germansolar-usa-inc/germansolar-usa-inc-gsp-270w/) GermanSolar USA Inc | 270.0 W | Tie (0 W) | 37.92 V | 16.27% | 92.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Lumos S48-270-29-IM?

Evaluate Lumos S48-270-29-IM (270.0 W STC, 32.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Lumos S48-270-29-IM reaches 37.24 V per panel—exceeding 16 panels in series voids 600 V inverter warranties.
- Footprint constraint: 30 panels for an 8 kW build require 623 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (623 sq ft).
- 2026 tax credit baseline: cash residential installs of Lumos S48-270-29-IM carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Lumos S48-270-29-IM 8 kW Residential Fit

Needs 30 modules (623 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 16 panels (-10 C) or 16 panels (-20 C), or compare CSI Solar Co Ltd CS6PH-260P.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 250.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Lumos S48-270-29-IM by Lumos grounded in CEC test data and NEC 690.7/690.8 limits. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

### Why is Lumos S48-270-29-IM PTC wattage (250.2 W) lower than STC (270.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 250.2 W PTC (92.7% retention) across Lumos S48-270-29-IM's 1.93 m2 aperture.

### Who should skip Lumos S48-270-29-IM on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 30 Lumos S48-270-29-IM panels (623 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS6PH-260P.

### What is the 1,000 V commercial string limit for Lumos S48-270-29-IM?

On 1,000 V commercial inverters at -10 C (36.19 V cold Voc), Lumos S48-270-29-IM fits up to 27 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Lumos S48-270-29-IM.

## Related Pages

Compare Lumos equipment, CSI Solar Co Ltd CS6PH-260P specs, utility payback rates, and NEC string calculators alongside Lumos S48-270-29-IM.

[All Lumos Certified Solar Models](https://epri-peac.com/solar-equipment/brands/lumos/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Lumos

- [All Lumos Specs](https://epri-peac.com/solar-equipment/brands/lumos/)
- [Lumos L72-430-08-xx](https://epri-peac.com/solar-equipment/modules/lumos/lumos-l72-430-08-xx/)
- [Lumos L72-415-08-xx](https://epri-peac.com/solar-equipment/modules/lumos/lumos-l72-415-08-xx/)
- [Lumos GSX 72/72](https://epri-peac.com/solar-equipment/modules/lumos/lumos-gsx-72-72/)
- [Lumos GSX360-72M](https://epri-peac.com/solar-equipment/modules/lumos/lumos-gsx360-72m/)
- [Lumos L60-355-21-xx](https://epri-peac.com/solar-equipment/modules/lumos/lumos-l60-355-21-xx/)