title: "Lumos L40-235-47-xx Specs (235.0W, 27.3V Voc)"
url: https://epri-peac.com/solar-equipment/modules/lumos/lumos-l40-235-47-xx/
description: "CEC datasheet for Lumos L40-235-47-xx: 235.0W STC, 27.3V Voc, 35-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Lumos L40-235-47-xx — CEC Solar Module Specifications

Manufacturer: [**Lumos**](https://epri-peac.com/solar-equipment/brands/lumos/) Registry: **CEC Verified Engineering Specification**

Lumos L40-235-47-xx is a 235.0 W STC (216.7 W PTC) Mono-c-Si solar module ranking #20,368 of 21,677 CEC listings (below all-CEC median; higher than 5.4% of peers). It delivers 10.31% efficiency, 27.3 V Voc at 25 C, and 30.4 V cold Voc at -10 C (19 panels max per 600 V string).

- **STC Wattage** : 235.0 W

- **PTC Wattage** : 216.7 W

- **Voc @ 25C** : 27.3 V

- **Efficiency** : 10.31%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Lumos L40-235-47-xx Compare Against Peer CEC Listings?

How Lumos Lumos L40-235-47-xx handles rooftop heat (216.7 W PTC), 8 kW sizing, and cold winter string voltage.

Lumos builds the Lumos L40-235-47-xx (Mono-c-Si) as a compact residential or specialty off-grid module delivering 103.1 W/m2 (9.60 percentage points below 19.91% CEC median). Compared against Gintung Energy ASEC-235G6M69 (235.0 W), this model holds strong 92.2% PTC-to-STC heat retention (#13,542 of 21,677). Lower 27.3 V string voltage fits 19 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 17.63 A overcurrent floor served by a 20 A breaker.

## Where Does Lumos L40-235-47-xx Fall Across Listed CEC Models?

Where Lumos L40-235-47-xx (235.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Lumos L40-235-47-xx?

Percentile placement of Lumos L40-235-47-xx across power density (103.1 W/m2), thermal retention, and nameplate STC wattage. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

## What Do the Dataset Ranks Show for Lumos L40-235-47-xx?

Four critical engineering numbers homeowners and solar installers check first when reviewing Lumos L40-235-47-xx specifications. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Rank #20,368 / 21,677

### 235.0 W STC · Higher Than 5.4%

235.0 W STC (-150.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #21,619

### 10.31% Aperture Efficiency

Power density 103.1 W/m2 (9.60 percentage points below 19.91% CEC median). PTC/STC ratio: 92.2% (rank #13,542).

NEC 690.7 Limit

### 19 Panels Max @ -10 C (600 V)

Cold Voc reaches 30.4 V at -10 C (577.6 V string) and 31.28 V at -20 C (19 max).

 8 kW Reference Array

### 35 Panels = 8,225 W STC

Occupies 79.8 m2 (859 sq ft) producing 7,584 W PTC; NEC 690.8 OCPD floor is 17.63 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 27.3 * (1 + (-0.324/100) * (-10 - 25)) = 30.4 V | OCPD = 1.56 * 11.3 = 17.63 A

Inputs from CEC Modules.csv for Lumos L40-235-47-xx: Voc=27.3 V, beta_Voc=-0.324%/C, Isc=11.3 A, STC=235.0 W, Area=2.28 m2.

**Result:** 19 panels max on 600 V (577.6 V); 35 panels for 8 kW (859 sq ft).

## What Are the Published CEC Specifications for Lumos L40-235-47-xx?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Lumos L40-235-47-xx. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Official California Energy Commission (NREL SAM) test parameters for Lumos L40-235-47-xx.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 235.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 216.7 W (92.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 27.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 11.3 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 22.14 V / 10.7 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.324 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 10.31% (2.28 m2) | Array roof footprint density |
| **Cell Count & Technology** | 40 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Lumos L40-235-47-xx Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Lumos L40-235-47-xx (235.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 26 | 6.11 kW | 638 sq ft | $1,529 | $2,586 |
| **8 kW Class** | 35 | 8.22 kW | 859 sq ft | $2,057 | $3,479 |
| **10 kW Class** | 43 | 10.11 kW | 1,055 sq ft | $2,530 | $4,279 |

## Which Sibling Wattage & Trim Variants Belong to This Lumos Series?

All closely matched Lumos wattages and cosmetic trims sharing the Lumos L40-235-47-xx architecture. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Sibling CEC listings grouped into the Lumos L40-235-47-xx wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Lumos L40-225-47-xx** | 225.0 W | 207.4 W | 27.1 V | 21.94 V | 9.87% |
| **Lumos L40-230-47-xx** | 230.0 W | 212.1 W | 27.2 V | 22.04 V | 10.09% |
| **Lumos L40-235-47-xx** | 235.0 W | 216.7 W | 27.3 V | 22.14 V | 10.31% |
| **Lumos L40-240-47-xx** | 240.0 W | 221.4 W | 27.4 V | 22.25 V | 10.53% |

## How Many Lumos L40-235-47-xx Modules Fit in a Cold-Weather String?

Maximum series module counts for Lumos L40-235-47-xx from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=27.3V and beta_Voc=-0.324%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 31.28 V | 19 panels | 594.3 V | 31 panels |
| **-10 C (14 F)** | 30.4 V | 19 panels | 577.6 V | 32 panels |
| **0 C (32 F)** | 29.51 V | 20 panels | 590.2 V | 33 panels |
| **25 C (77 F STC)** | 27.3 V | 21 panels | 573.3 V | 36 panels |

## Which Cross-Brand Solar Modules Compare Closest to Lumos L40-235-47-xx?

Alternative CEC solar modules from competing brands near Lumos L40-235-47-xx (235.0 W), including Gintung Energy ASEC-235G6M69. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Gintung Energy ASEC-235G6M69**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-235g6m69/) Gintung Energy | 235.0 W | Tie (0 W) | 34.06 V | 16.04% | 88.1% |
| [**Gintung Energy GTEC-235G6M69**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-235g6m69/) Gintung Energy | 235.0 W | Tie (0 W) | 34.06 V | 16.04% | 88.1% |
| [**Gintung Energy ASEC-235G6S69**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-235g6s69/) Gintung Energy | 235.0 W | Tie (0 W) | 34.13 V | 16.04% | 87.7% |
| [**Gintung Energy GTEC-235G6S69**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-235g6s69/) Gintung Energy | 235.0 W | Tie (0 W) | 34.13 V | 16.04% | 87.7% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Lumos L40-235-47-xx?

Evaluate Lumos L40-235-47-xx (235.0 W STC, 27.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Lumos L40-235-47-xx reaches 31.28 V per panel—exceeding 19 panels in series voids 600 V inverter warranties.
- Footprint constraint: 35 panels for an 8 kW build require 859 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (859 sq ft).
- 2026 tax credit baseline: cash residential installs of Lumos L40-235-47-xx carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Lumos L40-235-47-xx 8 kW Residential Fit

Needs 35 modules (859 sq ft) with a 20 A string OCPD, offsetting ~$2,057/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 19 panels (-10 C) or 19 panels (-20 C), or compare Gintung Energy ASEC-235G6M69.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 216.7 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Lumos L40-235-47-xx by Lumos grounded in CEC test data and NEC 690.7/690.8 limits. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

### What fuse or breaker size does NEC 690.8 require for Lumos L40-235-47-xx?

Multiplying Lumos L40-235-47-xx's 11.3 A short-circuit current by 1.56 equals 17.63 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker. Check local building department permit requirements for Lumos L40-235-47-xx before finalizing component orders.

### Can Lumos L40-235-47-xx pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 30.4 V cold Voc at 14 F and handles 11.3 A Isc; string inverters cap Lumos L40-235-47-xx at 19 panels on 600 V.

### Is Lumos L40-235-47-xx eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Lumos L40-235-47-xx rely on utility bill offset (~$2,057/yr at 8 kW) rather than 25D.

## Related Pages

Compare Lumos equipment, Gintung Energy ASEC-235G6M69 specs, utility payback rates, and NEC string calculators alongside Lumos L40-235-47-xx. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

[All Lumos Certified Solar Models](https://epri-peac.com/solar-equipment/brands/lumos/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Lumos

- [All Lumos Specs](https://epri-peac.com/solar-equipment/brands/lumos/)
- [Lumos L72-430-08-xx](https://epri-peac.com/solar-equipment/modules/lumos/lumos-l72-430-08-xx/)
- [Lumos L72-415-08-xx](https://epri-peac.com/solar-equipment/modules/lumos/lumos-l72-415-08-xx/)
- [Lumos GSX 72/72](https://epri-peac.com/solar-equipment/modules/lumos/lumos-gsx-72-72/)
- [Lumos GSX360-72M](https://epri-peac.com/solar-equipment/modules/lumos/lumos-gsx360-72m/)
- [Lumos L60-355-21-xx](https://epri-peac.com/solar-equipment/modules/lumos/lumos-l60-355-21-xx/)