# Luma Resources LLC LRSS28-100A — CEC Solar Module Specifications

Manufacturer: [**Luma Resources LLC**](https://epri-peac.com/solar-equipment/brands/luma-resources-llc/) Registry: **CEC Verified Engineering Specification**

Luma Resources LLC LRSS28-100A is a 100.0 W STC (98.9 W PTC) Mono-c-Si solar module ranking #21,563 of 21,677 CEC listings (below all-CEC median; higher than 0.5% of peers). It delivers 17.24% efficiency, 9.73 V Voc at 25 C, and 10.61 V cold Voc at -10 C (56 panels max per 600 V string).

- **STC Wattage** : 100.0 W

- **PTC Wattage** : 98.9 W

- **Voc @ 25C** : 9.73 V

- **Efficiency** : 17.24%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Luma Resources LLC LRSS28-100A Compare Against Peer CEC Listings?

How Luma Resources LLC Luma Resources LLC LRSS28-100A handles rooftop heat (98.9 W PTC), 8 kW sizing, and cold winter string voltage.

Luma Resources LLC builds the Luma Resources LLC LRSS28-100A (Mono-c-Si) as a compact residential or specialty off-grid module delivering 172.4 W/m2 (2.67 percentage points below 19.91% CEC median). Compared against Heliene 20M-100GH (100.0 W), this model holds strong 98.9% PTC-to-STC heat retention (#11 of 21,677). Lower 9.73 V string voltage fits 56 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 20.83 A overcurrent floor served by a 25 A breaker.

## Where Does Luma Resources LLC LRSS28-100A Fall Across Listed CEC Models?

Where Luma Resources LLC LRSS28-100A (100.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Luma Resources LLC LRSS28-100A?

Percentile placement of Luma Resources LLC LRSS28-100A across power density (172.4 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Luma Resources LLC LRSS28-100A?

Four critical engineering numbers homeowners and solar installers check first when reviewing Luma Resources LLC LRSS28-100A specifications. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Rank #21,563 / 21,677

### 100.0 W STC · Higher Than 0.5%

100.0 W STC (-285.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #16,169

### 17.24% Aperture Efficiency

Power density 172.4 W/m2 (2.67 percentage points below 19.91% CEC median). PTC/STC ratio: 98.9% (rank #11).

NEC 690.7 Limit

### 56 Panels Max @ -10 C (600 V)

Cold Voc reaches 10.61 V at -10 C (594.2 V string) and 10.86 V at -20 C (55 max).

 8 kW Reference Array

### 80 Panels = 8,000 W STC

Occupies 46.4 m2 (499 sq ft) producing 7,912 W PTC; NEC 690.8 OCPD floor is 20.83 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 9.73 * (1 + (-0.259/100) * (-10 - 25)) = 10.61 V | OCPD = 1.56 * 13.35 = 20.83 A

Inputs from CEC Modules.csv for Luma Resources LLC LRSS28-100A: Voc=9.73 V, beta_Voc=-0.259%/C, Isc=13.35 A, STC=100.0 W, Area=0.58 m2.

**Result:** 56 panels max on 600 V (594.2 V); 80 panels for 8 kW (499 sq ft).

## What Are the Published CEC Specifications for Luma Resources LLC LRSS28-100A?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Luma Resources LLC LRSS28-100A.

Official California Energy Commission (NREL SAM) test parameters for Luma Resources LLC LRSS28-100A.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 100.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 98.9 W (98.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 9.73 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.35 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 7.8 V / 12.82 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.259 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 17.24% (0.58 m2) | Array roof footprint density |
| **Cell Count & Technology** | 28 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Luma Resources LLC LRSS28-100A Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Luma Resources LLC LRSS28-100A (100.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 60 | 6.0 kW | 375 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 80 | 8.0 kW | 499 sq ft | $2,002 | $3,386 |
| **10 kW Class** | 100 | 10.0 kW | 624 sq ft | $2,503 | $4,232 |

## How Many Luma Resources LLC LRSS28-100A Modules Fit in a Cold-Weather String?

Maximum series module counts for Luma Resources LLC LRSS28-100A from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=9.73V and beta_Voc=-0.259%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 10.86 V | 55 panels | 597.3 V | 92 panels |
| **-10 C (14 F)** | 10.61 V | 56 panels | 594.2 V | 94 panels |
| **0 C (32 F)** | 10.36 V | 57 panels | 590.5 V | 96 panels |
| **25 C (77 F STC)** | 9.73 V | 61 panels | 593.5 V | 102 panels |

## Which Cross-Brand Solar Modules Compare Closest to Luma Resources LLC LRSS28-100A?

Alternative CEC solar modules from competing brands near Luma Resources LLC LRSS28-100A (100.0 W), including Heliene 20M-100GH. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Heliene 20M-100GH**](https://epri-peac.com/solar-equipment/modules/heliene/heliene-20m-100gh/) Heliene | 100.0 W | Tie (0 W) | 13.3 V | 6.17% | 85.2% |
| [**Arka Energy Inc AEP-821-00015-A**](https://epri-peac.com/solar-equipment/modules/arka-energy-inc/arka-energy-inc-aep-821-00015-a/) Arka Energy Inc | 88.0 W | -12.0 W | 8.84 V | 14.92% | 91.5% |
| [**Merlin Solar Technologies Inc FXS 100-B**](https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-fxs-100-b/) Merlin Solar Technologies Inc | 100.0 W | Tie (0 W) | 15.33 V | 13.33% | 88.3% |
| [**CertainTeed Apollo II - 75x**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-apollo-ii-75x/) CertainTeed | 75.0 W | -25.0 W | 9.92 V | 14.15% | 85.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Luma Resources LLC LRSS28-100A?

Evaluate Luma Resources LLC LRSS28-100A (100.0 W STC, 9.73 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Luma Resources LLC LRSS28-100A reaches 10.86 V per panel—exceeding 55 panels in series voids 600 V inverter warranties.
- Footprint constraint: 80 panels for an 8 kW build require 499 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 80 panels (499 sq ft).
- 2026 tax credit baseline: cash residential installs of Luma Resources LLC LRSS28-100A carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Luma Resources LLC LRSS28-100A 8 kW Residential Fit

Needs 80 modules (499 sq ft) with a 25 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 56 panels (-10 C) or 55 panels (-20 C), or compare Heliene 20M-100GH.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 98.9 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Luma Resources LLC LRSS28-100A by Luma Resources LLC grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Luma Resources LLC LRSS28-100A?

Multiplying Luma Resources LLC LRSS28-100A's 13.35 A short-circuit current by 1.56 equals 20.83 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can Luma Resources LLC LRSS28-100A pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 10.61 V cold Voc at 14 F and handles 13.35 A Isc; string inverters cap Luma Resources LLC LRSS28-100A at 56 panels on 600 V.

### Is Luma Resources LLC LRSS28-100A eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Luma Resources LLC LRSS28-100A rely on utility bill offset (~$2,002/yr at 8 kW) rather than 25D.

## Related Pages

Compare Luma Resources LLC equipment, Heliene 20M-100GH specs, utility payback rates, and NEC string calculators alongside Luma Resources LLC LRSS28-100A.

[All Luma Resources LLC Certified Solar Models](https://epri-peac.com/solar-equipment/brands/luma-resources-llc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Luma Resources LLC

- [All Luma Resources LLC Specs](https://epri-peac.com/solar-equipment/brands/luma-resources-llc/)
- [Luma Resources LLC LRSS28-95A](https://epri-peac.com/solar-equipment/modules/luma-resources-llc/luma-resources-llc-lrss28-95a/)