CEC PV Module

# LONGi Green Energy Technology Co Ltd LR6-60PB-290M — CEC Solar Module Specifications

Manufacturer: [**LONGi Green Energy Technology Co Ltd**](https://epri-peac.com/solar-equipment/brands/longi-green-energy-technology-co-ltd/) Registry: **CEC Verified Engineering Specification**

LONGi Green Energy Technology Co Ltd LR6-60PB-290M is a 290.0 W STC (263.6 W PTC) Mono-c-Si solar module ranking #17,253 of 21,677 CEC listings (below all-CEC median; higher than 18.8% of peers). It delivers 17.74% efficiency, 39.7 V Voc at 25 C, and 43.65 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 290.0 W

- **PTC Wattage** : 263.6 W

- **Voc @ 25C** : 39.7 V

- **Efficiency** : 17.74%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does LONGi Green Energy Technology Co Ltd LR6-60PB-290M Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for LONGi Green Energy Technology Co Ltd LR6-60PB-290M (Mono-c-Si) residential solar systems.

Homeowners evaluating LONGi Green Energy Technology Co Ltd LR6-60PB-290M need 21 panels for 6 kW or 28 panels (493 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (493 sq ft). Under NEC 690.7(A), beta_Voc (-0.284%/C) pushes open-circuit voltage to 43.65 V at 14 F and 44.77 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does LONGi Green Energy Technology Co Ltd LR6-60PB-290M Fall Across Listed CEC Models?

Comparison of LONGi Green Energy Technology Co Ltd LR6-60PB-290M (290.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define LONGi Green Energy Technology Co Ltd LR6-60PB-290M?

Relative ranking of LONGi Green Energy Technology Co Ltd LR6-60PB-290M across nameplate watts, 90.9% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for LONGi Green Energy Technology Co Ltd LR6-60PB-290M?

Summary of LONGi Green Energy Technology Co Ltd LR6-60PB-290M output rank, 8 kW array size (28 panels), efficiency rating, and 600 V string limit.

Rank #17,253 / 21,677

### 290.0 W STC · Higher Than 18.8%

290.0 W STC (-95.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #15,451

### 17.74% Aperture Efficiency

Power density 177.4 W/m2 (2.17 percentage points below 19.91% CEC median). PTC/STC ratio: 90.9% (rank #16,906).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.65 V at -10 C (567.4 V string) and 44.77 V at -20 C (13 max).

 8 kW Reference Array

### 28 Panels = 8,120 W STC

Occupies 45.8 m2 (493 sq ft) producing 7,381 W PTC; NEC 690.8 OCPD floor is 14.94 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.7 * (1 + (-0.284/100) * (-10 - 25)) = 43.65 V | OCPD = 1.56 * 9.58 = 14.94 A

Inputs from CEC Modules.csv for LONGi Green Energy Technology Co Ltd LR6-60PB-290M: Voc=39.7 V, beta_Voc=-0.284%/C, Isc=9.58 A, STC=290.0 W, Area=1.635 m2.

**Result:** 13 panels max on 600 V (567.4 V); 28 panels for 8 kW (493 sq ft).

## What Are the Published CEC Specifications for LONGi Green Energy Technology Co Ltd LR6-60PB-290M?

Complete CEC test sheet for LONGi Green Energy Technology Co Ltd LR6-60PB-290M including Isc (9.58 A), Voc (39.7 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for LONGi Green Energy Technology Co Ltd LR6-60PB-290M.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 290.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 263.6 W (90.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 39.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.58 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 32.3 V / 8.98 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.284 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 17.74% (1.635 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many LONGi Green Energy Technology Co Ltd LR6-60PB-290M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using LONGi Green Energy Technology Co Ltd LR6-60PB-290M.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 21 | 6.09 kW | 370 sq ft | $1,524 | $2,577 |
| **8 kW Class** | 28 | 8.12 kW | 493 sq ft | $2,032 | $3,437 |
| **10 kW Class** | 35 | 10.15 kW | 616 sq ft | $2,540 | $4,296 |

## Which Sibling Wattage & Trim Variants Belong to This LONGi Green Energy Technology Co Ltd Series?

Related LONGi Green Energy Technology Co Ltd power steps and black/silver trims consolidated into this LONGi Green Energy Technology Co Ltd LR6-60PB-290M series guide.

Sibling CEC listings grouped into the LONGi Green Energy Technology Co Ltd LR6-60PB-290M wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **LONGi Green Energy Technology Co Ltd LR6-60PB-280M** | 280.0 W | 254.2 W | 39.3 V | 32.0 V | 17.13% |
| **LONGi Green Energy Technology Co Ltd LR6-60PB-285M** | 285.0 W | 258.9 W | 39.5 V | 32.1 V | 17.43% |
| **LONGi Green Energy Technology Co Ltd LR6-60PB-290M** | 290.0 W | 263.6 W | 39.7 V | 32.3 V | 17.74% |
| **LONGi Green Energy Technology Co Ltd LR6-60PB-295M** | 295.0 W | 268.3 W | 39.9 V | 32.6 V | 18.04% |

## How Many LONGi Green Energy Technology Co Ltd LR6-60PB-290M Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for LONGi Green Energy Technology Co Ltd LR6-60PB-290M (39.7 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=39.7V and beta_Voc=-0.284%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 44.77 V | 13 panels | 582.0 V | 22 panels |
| **-10 C (14 F)** | 43.65 V | 13 panels | 567.4 V | 22 panels |
| **0 C (32 F)** | 42.52 V | 14 panels | 595.3 V | 23 panels |
| **25 C (77 F STC)** | 39.7 V | 15 panels | 595.5 V | 25 panels |

## Which Cross-Brand Solar Modules Compare Closest to LONGi Green Energy Technology Co Ltd LR6-60PB-290M?

Four comparable CEC modules such as DualSun SAS DualSun 290M-60-00 (290.0 W) for side-by-side solar quote checks. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**DualSun SAS DualSun 290M-60-00**](https://epri-peac.com/solar-equipment/modules/dualsun-sas/dualsun-sas-dualsun-290m-60-00/) DualSun SAS | 290.0 W | Tie (0 W) | 39.7 V | 17.68% | 90.9% |
| [**CertainTeed CT290M10-02**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ct290m10-02/) CertainTeed | 290.0 W | Tie (0 W) | 39.77 V | 17.83% | 91.8% |
| [**CertainTeed CT290M11-02**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ct290m11-02/) CertainTeed | 290.0 W | Tie (0 W) | 39.77 V | 17.83% | 91.8% |
| [**AXITEC AC-290M/60S**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-290m-60s/) AXITEC | 290.0 W | Tie (0 W) | 39.42 V | 17.79% | 91.1% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for LONGi Green Energy Technology Co Ltd LR6-60PB-290M?

Evaluate LONGi Green Energy Technology Co Ltd LR6-60PB-290M (290.0 W STC, 39.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), LONGi Green Energy Technology Co Ltd LR6-60PB-290M reaches 44.77 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 28 panels for an 8 kW build require 493 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (493 sq ft).
- 2026 tax credit baseline: cash residential installs of LONGi Green Energy Technology Co Ltd LR6-60PB-290M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### LONGi Green Energy Technology Co Ltd LR6-60PB-290M 8 kW Residential Fit

Needs 28 modules (493 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare DualSun SAS DualSun 290M-60-00.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 263.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for LONGi Green Energy Technology Co Ltd LR6-60PB-290M by LONGi Green Energy Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is LONGi Green Energy Technology Co Ltd LR6-60PB-290M PTC wattage (263.6 W) lower than STC (290.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 263.6 W PTC (90.9% retention) across LONGi Green Energy Technology Co Ltd LR6-60PB-290M's 1.635 m2 aperture.

### Who should skip LONGi Green Energy Technology Co Ltd LR6-60PB-290M on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 28 LONGi Green Energy Technology Co Ltd LR6-60PB-290M panels (493 sq ft) leave unusable roof gaps vs. DualSun SAS DualSun 290M-60-00.

### What is the 1,000 V commercial string limit for LONGi Green Energy Technology Co Ltd LR6-60PB-290M?

On 1,000 V commercial inverters at -10 C (43.65 V cold Voc), LONGi Green Energy Technology Co Ltd LR6-60PB-290M fits up to 22 panels per series string.

## Related Pages

Compare LONGi Green Energy Technology Co Ltd equipment, DualSun SAS DualSun 290M-60-00 specs, utility payback rates, and NEC string calculators alongside LONGi Green Energy Technology Co Ltd LR6-60PB-290M.

[All LONGi Green Energy Technology Co Ltd Certified Solar Models](https://epri-peac.com/solar-equipment/brands/longi-green-energy-technology-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From LONGi Green Energy Technology Co Ltd

- [All LONGi Green Energy Technology Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/longi-green-energy-technology-co-ltd/)
- [LONGi Green Energy Technology Co Ltd LR5-78HBD-605M](https://epri-peac.com/solar-equipment/modules/longi-green-energy-technology-co-ltd/longi-green-energy-technology-co-ltd-lr5-78hbd-605m/)
- [LONGi Green Energy Technology Co Ltd LR5-78HBD-585M](https://epri-peac.com/solar-equipment/modules/longi-green-energy-technology-co-ltd/longi-green-energy-technology-co-ltd-lr5-78hbd-585m/)
- [LONGi Green Energy Technology Co Ltd LR5-72HBD-560M](https://epri-peac.com/solar-equipment/modules/longi-green-energy-technology-co-ltd/longi-green-energy-technology-co-ltd-lr5-72hbd-560m/)
- [LONGi Green Energy Technology Co Ltd LR5-72HPH-560M](https://epri-peac.com/solar-equipment/modules/longi-green-energy-technology-co-ltd/longi-green-energy-technology-co-ltd-lr5-72hph-560m/)
- [LONGi Green Energy Technology Co Ltd LR5-72HPH-540M](https://epri-peac.com/solar-equipment/modules/longi-green-energy-technology-co-ltd/longi-green-energy-technology-co-ltd-lr5-72hph-540m/)