title: "LOF SOLAR CORP LOF-MH92-C455 Specs (455.0W, 49.35V Voc)"
url: https://epri-peac.com/solar-equipment/modules/lof-solar-corp/lof-solar-corp-lof-mh92-c455/
description: "CEC datasheet for LOF SOLAR CORP LOF-MH92-C455: 455.0W STC, 49.35V Voc, 18-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# LOF SOLAR CORP LOF-MH92-C455 — CEC Solar Module Specifications

Manufacturer: [**LOF SOLAR CORP**](https://epri-peac.com/solar-equipment/brands/lof-solar-corp/) Registry: **CEC Verified Engineering Specification**

LOF SOLAR CORP LOF-MH92-C455 is a 455.0 W STC (420.8 W PTC) Mono-c-Si solar module ranking #5,417 of 21,677 CEC listings (top 26.2%; higher than 73.8% of peers). It delivers 21.16% efficiency, 49.35 V Voc at 25 C, and 54.93 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 455.0 W

- **PTC Wattage** : 420.8 W

- **Voc @ 25C** : 49.35 V

- **Efficiency** : 21.16%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does LOF SOLAR CORP LOF-MH92-C455 Compare Against Peer CEC Listings?

How LOF SOLAR CORP LOF SOLAR CORP LOF-MH92-C455 handles rooftop heat (420.8 W PTC), 8 kW sizing, and cold winter string voltage.

LOF SOLAR CORP builds the LOF SOLAR CORP LOF-MH92-C455 (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 211.6 W/m2 (1.25 percentage points above 19.91% CEC median). Compared against Boviet Solar Technology Co Ltd BVM6612M-455S-H-HC (455.0 W), this model holds strong 92.5% PTC-to-STC heat retention (#12,531 of 21,677). Higher 49.35 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), while NEC 690.8 sets a 17.72 A overcurrent floor served by a 20 A breaker.

## Where Does LOF SOLAR CORP LOF-MH92-C455 Fall Across Listed CEC Models?

Where LOF SOLAR CORP LOF-MH92-C455 (455.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define LOF SOLAR CORP LOF-MH92-C455?

Percentile placement of LOF SOLAR CORP LOF-MH92-C455 across power density (211.6 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for LOF SOLAR CORP LOF-MH92-C455?

Four critical engineering numbers homeowners and solar installers check first when reviewing LOF SOLAR CORP LOF-MH92-C455 specifications. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Rank #5,417 / 21,677

### Top 26.2% STC Output

455.0 W STC (+70.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,699

### 21.16% Aperture Efficiency

Power density 211.6 W/m2 (1.25 percentage points above 19.91% CEC median). PTC/STC ratio: 92.5% (rank #12,531).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.93 V at -10 C (549.3 V string) and 56.52 V at -20 C (10 max).

 8 kW Reference Array

### 18 Panels = 8,190 W STC

Occupies 38.7 m2 (417 sq ft) producing 7,574 W PTC; NEC 690.8 OCPD floor is 17.72 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.35 * (1 + (-0.323/100) * (-10 - 25)) = 54.93 V | OCPD = 1.56 * 11.36 = 17.72 A

Inputs from CEC Modules.csv for LOF SOLAR CORP LOF-MH92-C455: Voc=49.35 V, beta_Voc=-0.323%/C, Isc=11.36 A, STC=455.0 W, Area=2.15 m2.

**Result:** 10 panels max on 600 V (549.3 V); 18 panels for 8 kW (417 sq ft).

## What Are the Published CEC Specifications for LOF SOLAR CORP LOF-MH92-C455?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for LOF SOLAR CORP LOF-MH92-C455.

Official California Energy Commission (NREL SAM) test parameters for LOF SOLAR CORP LOF-MH92-C455.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 455.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 420.8 W (92.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 49.35 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 11.36 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 42.0 V / 10.84 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.323 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.16% (2.15 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many LOF SOLAR CORP LOF-MH92-C455 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using LOF SOLAR CORP LOF-MH92-C455 (455.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 14 | 6.37 kW | 324 sq ft | $1,594 | $2,696 |
| **8 kW Class** | 18 | 8.19 kW | 417 sq ft | $2,050 | $3,466 |
| **10 kW Class** | 22 | 10.01 kW | 509 sq ft | $2,505 | $4,236 |

## Which Sibling Wattage & Trim Variants Belong to This LOF SOLAR CORP Series?

All closely matched LOF SOLAR CORP wattages and cosmetic trims sharing the LOF SOLAR CORP LOF-MH92-C455 architecture. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sibling CEC listings grouped into the LOF SOLAR CORP LOF-MH92-C455 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **LOF SOLAR CORP LOF-MH92-C450** | 450.0 W | 416.1 W | 49.2 V | 41.85 V | 20.93% |
| **LOF SOLAR CORP LOF-MH92-C455** | 455.0 W | 420.8 W | 49.35 V | 42.0 V | 21.16% |
| **LOF SOLAR CORP LOF-MH92-C460** | 460.0 W | 425.6 W | 49.5 V | 42.15 V | 21.4% |

## How Many LOF SOLAR CORP LOF-MH92-C455 Modules Fit in a Cold-Weather String?

Maximum series module counts for LOF SOLAR CORP LOF-MH92-C455 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=49.35V and beta_Voc=-0.323%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 56.52 V | 10 panels | 565.2 V | 17 panels |
| **-10 C (14 F)** | 54.93 V | 10 panels | 549.3 V | 18 panels |
| **0 C (32 F)** | 53.34 V | 11 panels | 586.7 V | 18 panels |
| **25 C (77 F STC)** | 49.35 V | 12 panels | 592.2 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to LOF SOLAR CORP LOF-MH92-C455?

Alternative CEC solar modules from competing brands near LOF SOLAR CORP LOF-MH92-C455 (455.0 W), including Boviet Solar Technology Co Ltd BVM6612M-455S-H-HC.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Boviet Solar Technology Co Ltd BVM6612M-455S-H-HC**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-455s-h-hc/) Boviet Solar Technology Co Ltd | 455.0 W | Tie (0 W) | 49.25 V | 20.68% | 93.8% |
| [**Caterpillar Inc PVC455MP03H**](https://epri-peac.com/solar-equipment/modules/caterpillar-inc/caterpillar-inc-pvc455mp03h/) Caterpillar Inc | 455.0 W | Tie (0 W) | 49.5 V | 21.46% | 93.7% |
| [**ELITE Solar ET-M672BH455WW**](https://epri-peac.com/solar-equipment/modules/elite-solar/elite-solar-et-m672bh455ww/) ELITE Solar | 455.0 W | Tie (0 W) | 49.5 V | 21.16% | 93.6% |
| [**Apollo Renewables Inc Apollo-M672BH-455TW**](https://epri-peac.com/solar-equipment/modules/apollo-renewables-inc/apollo-renewables-inc-apollo-m672bh-455tw/) Apollo Renewables Inc | 455.0 W | Tie (0 W) | 49.8 V | 21.16% | 93.5% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for LOF SOLAR CORP LOF-MH92-C455?

Evaluate LOF SOLAR CORP LOF-MH92-C455 (455.0 W STC, 49.35 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), LOF SOLAR CORP LOF-MH92-C455 reaches 56.52 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 417 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (417 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of LOF SOLAR CORP LOF-MH92-C455 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### LOF SOLAR CORP LOF-MH92-C455 8 kW Residential Fit

Needs 18 modules (417 sq ft) with a 20 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-455S-H-HC.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 420.8 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for LOF SOLAR CORP LOF-MH92-C455 by LOF SOLAR CORP grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for LOF SOLAR CORP LOF-MH92-C455?

Multiplying LOF SOLAR CORP LOF-MH92-C455's 11.36 A short-circuit current by 1.56 equals 17.72 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

### Can LOF SOLAR CORP LOF-MH92-C455 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 54.93 V cold Voc at 14 F and handles 11.36 A Isc; string inverters cap LOF SOLAR CORP LOF-MH92-C455 at 10 panels on 600 V.

### Is LOF SOLAR CORP LOF-MH92-C455 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of LOF SOLAR CORP LOF-MH92-C455 rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.

## Related Pages

Compare LOF SOLAR CORP equipment, Boviet Solar Technology Co Ltd BVM6612M-455S-H-HC specs, utility payback rates, and NEC string calculators alongside LOF SOLAR CORP LOF-MH92-C455.

[All LOF SOLAR CORP Certified Solar Models](https://epri-peac.com/solar-equipment/brands/lof-solar-corp/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From LOF SOLAR CORP

- [All LOF SOLAR CORP Specs](https://epri-peac.com/solar-equipment/brands/lof-solar-corp/)
- [LOF SOLAR CORP LOF-MH92-C435](https://epri-peac.com/solar-equipment/modules/lof-solar-corp/lof-solar-corp-lof-mh92-c435/)
- [LOF SOLAR CORP LOF-MH82-C410](https://epri-peac.com/solar-equipment/modules/lof-solar-corp/lof-solar-corp-lof-mh82-c410/)
- [LOF SOLAR CORP LOF-MH92-C410](https://epri-peac.com/solar-equipment/modules/lof-solar-corp/lof-solar-corp-lof-mh92-c410/)
- [LOF SOLAR CORP LOF-MG81-C400](https://epri-peac.com/solar-equipment/modules/lof-solar-corp/lof-solar-corp-lof-mg81-c400/)
- [LOF SOLAR CORP LOF-MG81-C385](https://epri-peac.com/solar-equipment/modules/lof-solar-corp/lof-solar-corp-lof-mg81-c385/)