title: "LOF SOLAR CORP LOF-MH62-C360 Specs (360.0W, 40.4V Voc)"
url: https://epri-peac.com/solar-equipment/modules/lof-solar-corp/lof-solar-corp-lof-mh62-c360/
description: "CEC datasheet for LOF SOLAR CORP LOF-MH62-C360: 360.0W STC, 40.4V Voc, 23-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# LOF SOLAR CORP LOF-MH62-C360 — CEC Solar Module Specifications

Manufacturer: [**LOF SOLAR CORP**](https://epri-peac.com/solar-equipment/brands/lof-solar-corp/) Registry: **CEC Verified Engineering Specification**

LOF SOLAR CORP LOF-MH62-C360 is a 360.0 W STC (332.4 W PTC) Mono-c-Si solar module ranking #12,385 of 21,677 CEC listings (below all-CEC median; higher than 41.3% of peers). It delivers 20.0% efficiency, 40.4 V Voc at 25 C, and 44.97 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 360.0 W

- **PTC Wattage** : 332.4 W

- **Voc @ 25C** : 40.4 V

- **Efficiency** : 20.0%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does LOF SOLAR CORP LOF-MH62-C360 Compare Against Peer CEC Listings?

How LOF SOLAR CORP LOF SOLAR CORP LOF-MH62-C360 handles rooftop heat (332.4 W PTC), 8 kW sizing, and cold winter string voltage.

LOF SOLAR CORP builds the LOF SOLAR CORP LOF-MH62-C360 (Mono-c-Si) as a compact residential or specialty off-grid module delivering 200.0 W/m2 (0.09 percentage points above 19.91% CEC median). Compared against CSI Solar Co Ltd CS3L-360MS (360.0 W), this model holds strong 92.3% PTC-to-STC heat retention (#13,268 of 21,677). Mid-range 40.4 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, while NEC 690.8 sets a 17.18 A overcurrent floor served by a 20 A breaker.

## Where Does LOF SOLAR CORP LOF-MH62-C360 Fall Across Listed CEC Models?

Where LOF SOLAR CORP LOF-MH62-C360 (360.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define LOF SOLAR CORP LOF-MH62-C360?

Percentile placement of LOF SOLAR CORP LOF-MH62-C360 across power density (200.0 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for LOF SOLAR CORP LOF-MH62-C360?

Four critical engineering numbers homeowners and solar installers check first when reviewing LOF SOLAR CORP LOF-MH62-C360 specifications. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Rank #12,385 / 21,677

### 360.0 W STC · Higher Than 41.3%

360.0 W STC (-25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #10,442

### 20.0% Aperture Efficiency

Power density 200.0 W/m2 (0.09 percentage points above 19.91% CEC median). PTC/STC ratio: 92.3% (rank #13,268).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.97 V at -10 C (584.6 V string) and 46.27 V at -20 C (12 max).

 8 kW Reference Array

### 23 Panels = 8,280 W STC

Occupies 41.4 m2 (446 sq ft) producing 7,645 W PTC; NEC 690.8 OCPD floor is 17.18 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.4 * (1 + (-0.323/100) * (-10 - 25)) = 44.97 V | OCPD = 1.56 * 11.01 = 17.18 A

Inputs from CEC Modules.csv for LOF SOLAR CORP LOF-MH62-C360: Voc=40.4 V, beta_Voc=-0.323%/C, Isc=11.01 A, STC=360.0 W, Area=1.8 m2.

**Result:** 13 panels max on 600 V (584.6 V); 23 panels for 8 kW (446 sq ft).

## What Are the Published CEC Specifications for LOF SOLAR CORP LOF-MH62-C360?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for LOF SOLAR CORP LOF-MH62-C360.

Official California Energy Commission (NREL SAM) test parameters for LOF SOLAR CORP LOF-MH62-C360.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 360.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 332.4 W (92.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 40.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 11.01 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 34.3 V / 10.5 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.323 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.0% (1.8 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many LOF SOLAR CORP LOF-MH62-C360 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using LOF SOLAR CORP LOF-MH62-C360 (360.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 17 | 6.12 kW | 329 sq ft | $1,532 | $2,590 |
| **8 kW Class** | 23 | 8.28 kW | 446 sq ft | $2,072 | $3,504 |
| **10 kW Class** | 28 | 10.08 kW | 543 sq ft | $2,523 | $4,266 |

## Which Sibling Wattage & Trim Variants Belong to This LOF SOLAR CORP Series?

All closely matched LOF SOLAR CORP wattages and cosmetic trims sharing the LOF SOLAR CORP LOF-MH62-C360 architecture. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the LOF SOLAR CORP LOF-MH62-C360 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **LOF SOLAR CORP LOF-MH62-C350** | 350.0 W | 322.9 W | 40.1 V | 34.0 V | 19.44% |
| **LOF SOLAR CORP LOF-MH62-C355** | 355.0 W | 327.6 W | 40.25 V | 34.15 V | 19.72% |
| **LOF SOLAR CORP LOF-MH62-C360** | 360.0 W | 332.4 W | 40.4 V | 34.3 V | 20.0% |
| **LOF SOLAR CORP LOF-MH62-C365** | 365.0 W | 337.1 W | 40.55 V | 34.45 V | 20.28% |
| **LOF SOLAR CORP LOF-MH62-C370** | 370.0 W | 341.9 W | 40.7 V | 34.6 V | 20.56% |

## How Many LOF SOLAR CORP LOF-MH62-C360 Modules Fit in a Cold-Weather String?

Maximum series module counts for LOF SOLAR CORP LOF-MH62-C360 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=40.4V and beta_Voc=-0.323%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 46.27 V | 12 panels | 555.2 V | 21 panels |
| **-10 C (14 F)** | 44.97 V | 13 panels | 584.6 V | 22 panels |
| **0 C (32 F)** | 43.66 V | 13 panels | 567.6 V | 22 panels |
| **25 C (77 F STC)** | 40.4 V | 14 panels | 565.6 V | 24 panels |

## Which Cross-Brand Solar Modules Compare Closest to LOF SOLAR CORP LOF-MH62-C360?

Alternative CEC solar modules from competing brands near LOF SOLAR CORP LOF-MH62-C360 (360.0 W), including CSI Solar Co Ltd CS3L-360MS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS3L-360MS**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3l-360ms/) CSI Solar Co Ltd | 360.0 W | Tie (0 W) | 40.4 V | 20.11% | 93.0% |
| [**Apollo Renewables Inc Apollo-M660BH-360BB**](https://epri-peac.com/solar-equipment/modules/apollo-renewables-inc/apollo-renewables-inc-apollo-m660bh-360bb/) Apollo Renewables Inc | 360.0 W | Tie (0 W) | 40.5 V | 20.0% | 93.6% |
| [**AXITEC AC-360MH/120V**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-360mh-120v/) AXITEC | 360.0 W | Tie (0 W) | 40.5 V | 19.89% | 92.3% |
| [**AXITEC AC-360MH/120VB**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-360mh-120vb/) AXITEC | 360.0 W | Tie (0 W) | 40.5 V | 19.89% | 93.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for LOF SOLAR CORP LOF-MH62-C360?

Evaluate LOF SOLAR CORP LOF-MH62-C360 (360.0 W STC, 40.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), LOF SOLAR CORP LOF-MH62-C360 reaches 46.27 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 23 panels for an 8 kW build require 446 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (446 sq ft).
- 2026 tax credit baseline: cash residential installs of LOF SOLAR CORP LOF-MH62-C360 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### LOF SOLAR CORP LOF-MH62-C360 8 kW Residential Fit

Needs 23 modules (446 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare CSI Solar Co Ltd CS3L-360MS.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 332.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for LOF SOLAR CORP LOF-MH62-C360 by LOF SOLAR CORP grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for LOF SOLAR CORP LOF-MH62-C360?

Multiplying LOF SOLAR CORP LOF-MH62-C360's 11.01 A short-circuit current by 1.56 equals 17.18 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

### Can LOF SOLAR CORP LOF-MH62-C360 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 44.97 V cold Voc at 14 F and handles 11.01 A Isc; string inverters cap LOF SOLAR CORP LOF-MH62-C360 at 13 panels on 600 V.

### Is LOF SOLAR CORP LOF-MH62-C360 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of LOF SOLAR CORP LOF-MH62-C360 rely on utility bill offset (~$2,072/yr at 8 kW) rather than 25D.

## Related Pages

Compare LOF SOLAR CORP equipment, CSI Solar Co Ltd CS3L-360MS specs, utility payback rates, and NEC string calculators alongside LOF SOLAR CORP LOF-MH62-C360.

[All LOF SOLAR CORP Certified Solar Models](https://epri-peac.com/solar-equipment/brands/lof-solar-corp/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From LOF SOLAR CORP

- [All LOF SOLAR CORP Specs](https://epri-peac.com/solar-equipment/brands/lof-solar-corp/)
- [LOF SOLAR CORP LOF-MH92-C455](https://epri-peac.com/solar-equipment/modules/lof-solar-corp/lof-solar-corp-lof-mh92-c455/)
- [LOF SOLAR CORP LOF-MH92-C435](https://epri-peac.com/solar-equipment/modules/lof-solar-corp/lof-solar-corp-lof-mh92-c435/)
- [LOF SOLAR CORP LOF-MH82-C410](https://epri-peac.com/solar-equipment/modules/lof-solar-corp/lof-solar-corp-lof-mh82-c410/)
- [LOF SOLAR CORP LOF-MH92-C410](https://epri-peac.com/solar-equipment/modules/lof-solar-corp/lof-solar-corp-lof-mh92-c410/)
- [LOF SOLAR CORP LOF-MG81-C400](https://epri-peac.com/solar-equipment/modules/lof-solar-corp/lof-solar-corp-lof-mg81-c400/)