---
title: "Lightway Green New Energy Specs (300.0W, 45.08V Voc)"
url: https://epri-peac.com/solar-equipment/modules/lightway-green-new-energy/lightway-green-new-energy-lw300-35-p1960x990/
description: "CEC datasheet for Lightway Green New Energy LW300(35)P1960x990: 300.0W STC, 45.08V Voc, 27-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# Lightway Green New Energy LW300(35)P1960x990 — CEC Solar Module Specifications

Manufacturer: [**Lightway Green New Energy**](https://epri-peac.com/solar-equipment/brands/lightway-green-new-energy/) Registry: **CEC Verified Engineering Specification**

Lightway Green New Energy LW300(35)P1960x990 is a 300.0 W STC (268.6 W PTC) Multi-c-Si solar module ranking #16,498 of 21,677 CEC listings (below all-CEC median; higher than 22.1% of peers). It delivers 15.46% efficiency, 45.08 V Voc at 25 C, and 50.92 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 300.0 W

- **PTC Wattage** : 268.6 W

- **Voc @ 25C** : 45.08 V

- **Efficiency** : 15.46%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Lightway Green New Energy LW300(35)P1960x990 Compare Against Peer CEC Listings?

Engineering position of Lightway Green New Energy LW300(35)P1960x990 (300.0 W STC) vs. Auxin Solar AXN6P612T305G across 1,407 CEC Multi-c-Si solar modules.

Built with 72 Multi-c-Si cells, Lightway Green New Energy LW300(35)P1960x990 pairs typical 89.5% PTC-to-STC thermal output (268.6 W real-world rating) with 45.08 V nominal Voc. An 8 kW residential build (8,100 W DC, 7,252 W PTC) saves ~$2,027/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Auxin Solar AXN6P612T305G offers a 305.0 W alternative.

## Where Does Lightway Green New Energy LW300(35)P1960x990 Fall Across Listed CEC Models?

Plots Lightway Green New Energy LW300(35)P1960x990 at 300.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define Lightway Green New Energy LW300(35)P1960x990?

Benchmarks Lightway Green New Energy LW300(35)P1960x990 on STC wattage, thermal PTC/STC retention, and 15.46 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for Lightway Green New Energy LW300(35)P1960x990?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Lightway Green New Energy LW300(35)P1960x990 by Lightway Green New Energy.

Rank #16,498 / 21,677

### 300.0 W STC · Higher Than 22.1%

300.0 W STC (-85.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,977

### 15.46% Aperture Efficiency

Power density 154.6 W/m2 (4.45 percentage points below 19.91% CEC median). PTC/STC ratio: 89.5% (rank #19,939).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.92 V at -10 C (560.1 V string) and 52.59 V at -20 C (11 max).

 8 kW Reference Array

### 27 Panels = 8,100 W STC

Occupies 52.4 m2 (564 sq ft) producing 7,252 W PTC; NEC 690.8 OCPD floor is 13.54 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.08 * (1 + (-0.37/100) * (-10 - 25)) = 50.92 V | OCPD = 1.56 * 8.68 = 13.54 A

Inputs from CEC Modules.csv for Lightway Green New Energy LW300(35)P1960x990: Voc=45.08 V, beta_Voc=-0.37%/C, Isc=8.68 A, STC=300.0 W, Area=1.94 m2.

**Result:** 11 panels max on 600 V (560.1 V); 27 panels for 8 kW (564 sq ft).

## What Are the Published CEC Specifications for Lightway Green New Energy LW300(35)P1960x990?

Laboratory test ratings recorded for Lightway Green New Energy LW300(35)P1960x990 (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Lightway Green New Energy LW300(35)P1960x990.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 300.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 268.6 W (89.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 45.08 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.68 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 36.15 V / 8.31 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.37 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.46% (1.94 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Lightway Green New Energy LW300(35)P1960x990 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (564 sq ft at 8 kW), and estimated Year-1 electric bill offset for Lightway Green New Energy LW300(35)P1960x990.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 20 | 6.0 kW | 418 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 27 | 8.1 kW | 564 sq ft | $2,027 | $3,428 |
| **10 kW Class** | 34 | 10.2 kW | 710 sq ft | $2,553 | $4,317 |

## How Many Lightway Green New Energy LW300(35)P1960x990 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Lightway Green New Energy LW300(35)P1960x990 (beta_Voc -0.37%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=45.08V and beta_Voc=-0.37%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 52.59 V | 11 panels | 578.5 V | 19 panels |
| **-10 C (14 F)** | 50.92 V | 11 panels | 560.1 V | 19 panels |
| **0 C (32 F)** | 49.25 V | 12 panels | 591.0 V | 20 panels |
| **25 C (77 F STC)** | 45.08 V | 13 panels | 586.0 V | 22 panels |

## Which Cross-Brand Solar Modules Compare Closest to Lightway Green New Energy LW300(35)P1960x990?

Closest cross-brand CEC competitors to Lightway Green New Energy LW300(35)P1960x990 matched near 300.0 W STC and 45.08 V Voc, led by Auxin Solar AXN6P612T305G.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Auxin Solar AXN6P612T305G**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn6p612t305g/) Auxin Solar | 305.0 W | +5.0 W | 45.0 V | 15.63% | 90.3% |
| [**AXITEC AC-310P/156-72S**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-310p-156-72s/) AXITEC | 310.0 W | +10.0 W | 45.05 V | 16.01% | 89.0% |
| [**Auxin Solar AXN6M612T310**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn6m612t310/) Auxin Solar | 310.0 W | +10.0 W | 45.0 V | 15.89% | 89.4% |
| [**Centrosolar America DP72 310**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dp72-310/) Centrosolar America | 310.0 W | +10.0 W | 45.18 V | 15.94% | 90.2% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Lightway Green New Energy LW300(35)P1960x990?

Evaluate Lightway Green New Energy LW300(35)P1960x990 (300.0 W STC, 45.08 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Lightway Green New Energy LW300(35)P1960x990 reaches 52.59 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 27 panels for an 8 kW build require 564 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (564 sq ft).
- 2026 tax credit baseline: cash residential installs of Lightway Green New Energy LW300(35)P1960x990 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Lightway Green New Energy LW300(35)P1960x990 8 kW Residential Fit

Needs 27 modules (564 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Auxin Solar AXN6P612T305G.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 268.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Lightway Green New Energy LW300(35)P1960x990 by Lightway Green New Energy grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Lightway Green New Energy LW300(35)P1960x990?

Multiplying Lightway Green New Energy LW300(35)P1960x990's 8.68 A short-circuit current by 1.56 equals 13.54 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can Lightway Green New Energy LW300(35)P1960x990 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 50.92 V cold Voc at 14 F and handles 8.68 A Isc; string inverters cap Lightway Green New Energy LW300(35)P1960x990 at 11 panels on 600 V.

### Is Lightway Green New Energy LW300(35)P1960x990 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Lightway Green New Energy LW300(35)P1960x990 rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

## Related Pages

Compare Lightway Green New Energy equipment, Auxin Solar AXN6P612T305G specs, utility payback rates, and NEC string calculators alongside Lightway Green New Energy LW300(35)P1960x990.

[All Lightway Green New Energy Certified Solar Models](https://epri-peac.com/solar-equipment/brands/lightway-green-new-energy/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Lightway Green New Energy

- [All Lightway Green New Energy Specs](https://epri-peac.com/solar-equipment/brands/lightway-green-new-energy/)
- [Lightway Green New Energy LW315(35)P1960x990](https://epri-peac.com/solar-equipment/modules/lightway-green-new-energy/lightway-green-new-energy-lw315-35-p1960x990/)
- [Lightway Green New Energy LW315(35)P1970x990](https://epri-peac.com/solar-equipment/modules/lightway-green-new-energy/lightway-green-new-energy-lw315-35-p1970x990/)
- [Lightway Green New Energy LW310(35)P1960x990](https://epri-peac.com/solar-equipment/modules/lightway-green-new-energy/lightway-green-new-energy-lw310-35-p1960x990/)
- [Lightway Green New Energy LW310(35)P1970x990](https://epri-peac.com/solar-equipment/modules/lightway-green-new-energy/lightway-green-new-energy-lw310-35-p1970x990/)
- [Lightway Green New Energy LW305(35)P1960x990](https://epri-peac.com/solar-equipment/modules/lightway-green-new-energy/lightway-green-new-energy-lw305-35-p1960x990/)
