title: "LENERGY POWER INC LP-515-144M-W Specs (515.0W, 48.8V Voc)"
url: https://epri-peac.com/solar-equipment/modules/lenergy-power-inc/lenergy-power-inc-lp-515-144m-w/
description: "CEC datasheet for LENERGY POWER INC LP-515-144M-W: 515.0W STC, 48.8V Voc, 16-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# LENERGY POWER INC LP-515-144M-W — CEC Solar Module Specifications

Manufacturer: [**LENERGY POWER INC**](https://epri-peac.com/solar-equipment/brands/lenergy-power-inc/) Registry: **CEC Verified Engineering Specification**

LENERGY POWER INC LP-515-144M-W is a 515.0 W STC (481.2 W PTC) Mono-c-Si solar module ranking #4,316 of 21,677 CEC listings (top 20.2%; higher than 79.8% of peers). It delivers 20.04% efficiency, 48.8 V Voc at 25 C, and 53.48 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 515.0 W

- **PTC Wattage** : 481.2 W

- **Voc @ 25C** : 48.8 V

- **Efficiency** : 20.04%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does LENERGY POWER INC LP-515-144M-W Compare Against Peer CEC Listings?

Solar engineering breakdown for LENERGY POWER INC LP-515-144M-W: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from LENERGY POWER INC and peers, LENERGY POWER INC LP-515-144M-W stands 105.0 W above the 410.0 W Mono-c-Si median and strong 93.4% PTC-to-STC heat retention (#7,716 of 21,677). Sizing 6 kW (12 panels) to 10 kW (20 panels) yields $1,547-$2,578/yr in baseline US bill offset. Higher 48.8 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).

## Where Does LENERGY POWER INC LP-515-144M-W Fall Across Listed CEC Models?

Distribution marker showing LENERGY POWER INC LP-515-144M-W (515.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define LENERGY POWER INC LP-515-144M-W?

Dataset percentiles tracking LENERGY POWER INC LP-515-144M-W power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for LENERGY POWER INC LP-515-144M-W?

Benchmark highlights for LENERGY POWER INC LP-515-144M-W covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #4,316 / 21,677

### Top 20.2% STC Output

515.0 W STC (+130.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #10,397

### 20.04% Aperture Efficiency

Power density 200.4 W/m2 (0.13 percentage points above 19.91% CEC median). PTC/STC ratio: 93.4% (rank #7,716).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.48 V at -10 C (588.3 V string) and 54.82 V at -20 C (10 max).

 8 kW Reference Array

### 16 Panels = 8,240 W STC

Occupies 41.1 m2 (443 sq ft) producing 7,699 W PTC; NEC 690.8 OCPD floor is 20.89 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.8 * (1 + (-0.274/100) * (-10 - 25)) = 53.48 V | OCPD = 1.56 * 13.39 = 20.89 A

Inputs from CEC Modules.csv for LENERGY POWER INC LP-515-144M-W: Voc=48.8 V, beta_Voc=-0.274%/C, Isc=13.39 A, STC=515.0 W, Area=2.57 m2.

**Result:** 11 panels max on 600 V (588.3 V); 16 panels for 8 kW (443 sq ft).

## What Are the Published CEC Specifications for LENERGY POWER INC LP-515-144M-W?

Official CEC datasheet figures for LENERGY POWER INC LP-515-144M-W (Mono-c-Si) used in utility interconnection and permit reviews. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Official California Energy Commission (NREL SAM) test parameters for LENERGY POWER INC LP-515-144M-W.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 515.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 481.2 W (93.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 48.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.39 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 40.9 V / 12.58 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.274 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.04% (2.57 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many LENERGY POWER INC LP-515-144M-W Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many LENERGY POWER INC LP-515-144M-W modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 12 | 6.18 kW | 332 sq ft | $1,547 | $2,616 |
| **8 kW Class** | 16 | 8.24 kW | 443 sq ft | $2,062 | $3,487 |
| **10 kW Class** | 20 | 10.3 kW | 553 sq ft | $2,578 | $4,359 |

## Which Sibling Wattage & Trim Variants Belong to This LENERGY POWER INC Series?

Consolidated LENERGY POWER INC wattage variants sharing the LENERGY POWER INC LP-515-144M-W mechanical and cell layout. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sibling CEC listings grouped into the LENERGY POWER INC LP-515-144M-W wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **LENERGY POWER INC LP-505-144M-W** | 505.0 W | 471.6 W | 48.4 V | 40.5 V | 19.65% |
| **LENERGY POWER INC LP-510-144M-W** | 510.0 W | 476.4 W | 48.6 V | 40.7 V | 19.84% |
| **LENERGY POWER INC LP-515-144M-W** | 515.0 W | 481.2 W | 48.8 V | 40.9 V | 20.04% |
| **LENERGY POWER INC LP-520-144M-W** | 520.0 W | 486.0 W | 49.0 V | 41.1 V | 20.23% |

## How Many LENERGY POWER INC LP-515-144M-W Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on LENERGY POWER INC LP-515-144M-W (53.48 V at 14 F).

Computed from Voc=48.8V and beta_Voc=-0.274%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 54.82 V | 10 panels | 548.2 V | 18 panels |
| **-10 C (14 F)** | 53.48 V | 11 panels | 588.3 V | 18 panels |
| **0 C (32 F)** | 52.14 V | 11 panels | 573.5 V | 19 panels |
| **25 C (77 F STC)** | 48.8 V | 12 panels | 585.6 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to LENERGY POWER INC LP-515-144M-W?

Competing CEC solar panels closest to LENERGY POWER INC LP-515-144M-W in nameplate wattage and Voc, starting with Heliene 144HC-520 M10 SL.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Heliene 144HC-520 M10 SL**](https://epri-peac.com/solar-equipment/modules/heliene/heliene-144hc-520-m10-sl/) Heliene | 520.0 W | +5.0 W | 48.72 V | 20.88% | 93.4% |
| [**IMPERIAL STAR SOLAR(CAMBODIA) CO LTD ISM7-SHDB144-520/M**](https://epri-peac.com/solar-equipment/modules/imperial-star-solar-cambodia-co-ltd/imperial-star-solar-cambodia-co-ltd-ism7-shdb144-520-m/) IMPERIAL STAR SOLAR(CAMBODIA) CO LTD | 520.0 W | +5.0 W | 48.88 V | 20.31% | 93.9% |
| [**Chint New Energy Technology Co Ltd CHSM72M-HC-520**](https://epri-peac.com/solar-equipment/modules/chint-new-energy-technology-co-ltd/chint-new-energy-technology-co-ltd-chsm72m-hc-520/) Chint New Energy Technology Co Ltd | 520.0 W | +5.0 W | 48.9 V | 20.97% | 92.5% |
| [**AXITEC AC-520MH/144VB**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-520mh-144vb/) AXITEC | 520.0 W | +5.0 W | 49.0 V | 20.31% | 93.7% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for LENERGY POWER INC LP-515-144M-W?

Evaluate LENERGY POWER INC LP-515-144M-W (515.0 W STC, 48.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), LENERGY POWER INC LP-515-144M-W reaches 54.82 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 16 panels for an 8 kW build require 443 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 16 panels (443 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of LENERGY POWER INC LP-515-144M-W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### LENERGY POWER INC LP-515-144M-W 8 kW Residential Fit

Needs 16 modules (443 sq ft) with a 25 A string OCPD, offsetting ~$2,062/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Heliene 144HC-520 M10 SL.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 481.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for LENERGY POWER INC LP-515-144M-W by LENERGY POWER INC grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for LENERGY POWER INC LP-515-144M-W?

Multiplying LENERGY POWER INC LP-515-144M-W's 13.39 A short-circuit current by 1.56 equals 20.89 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can LENERGY POWER INC LP-515-144M-W pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 53.48 V cold Voc at 14 F and handles 13.39 A Isc; string inverters cap LENERGY POWER INC LP-515-144M-W at 11 panels on 600 V.

### Is LENERGY POWER INC LP-515-144M-W eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of LENERGY POWER INC LP-515-144M-W rely on utility bill offset (~$2,062/yr at 8 kW) rather than 25D.

## Related Pages

Compare LENERGY POWER INC equipment, Heliene 144HC-520 M10 SL specs, utility payback rates, and NEC string calculators alongside LENERGY POWER INC LP-515-144M-W.

[All LENERGY POWER INC Certified Solar Models](https://epri-peac.com/solar-equipment/brands/lenergy-power-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From LENERGY POWER INC

- [All LENERGY POWER INC Specs](https://epri-peac.com/solar-equipment/brands/lenergy-power-inc/)
- [LENERGY POWER INC LP-550-144M-B](https://epri-peac.com/solar-equipment/modules/lenergy-power-inc/lenergy-power-inc-lp-550-144m-b/)
- [LENERGY POWER INC LP-550-144M-W](https://epri-peac.com/solar-equipment/modules/lenergy-power-inc/lenergy-power-inc-lp-550-144m-w/)
- [LENERGY POWER INC LP-535-144M-B](https://epri-peac.com/solar-equipment/modules/lenergy-power-inc/lenergy-power-inc-lp-535-144m-b/)
- [LENERGY POWER INC LP-535-144M-W](https://epri-peac.com/solar-equipment/modules/lenergy-power-inc/lenergy-power-inc-lp-535-144m-w/)
- [LENERGY POWER INC LP-515-144M-B](https://epri-peac.com/solar-equipment/modules/lenergy-power-inc/lenergy-power-inc-lp-515-144m-b/)