title: "Jinko Solar Co Ltd JKMS245PP-60 Specs (245.0W, 37.4V Voc)"
url: https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkms245pp-60/
description: "CEC datasheet for Jinko Solar Co Ltd JKMS245PP-60: 245.0W STC, 37.4V Voc, 33-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Jinko Solar Co Ltd JKMS245PP-60 — CEC Solar Module Specifications

Manufacturer: [**Jinko Solar Co Ltd**](https://epri-peac.com/solar-equipment/brands/jinko-solar-co-ltd/) Registry: **CEC Verified Engineering Specification**

Jinko Solar Co Ltd JKMS245PP-60 is a 245.0 W STC (224.9 W PTC) Multi-c-Si solar module ranking #19,942 of 21,677 CEC listings (below all-CEC median; higher than 7.0% of peers). It delivers 14.97% efficiency, 37.4 V Voc at 25 C, and 41.56 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 245.0 W

- **PTC Wattage** : 224.9 W

- **Voc @ 25C** : 37.4 V

- **Efficiency** : 14.97%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Jinko Solar Co Ltd JKMS245PP-60 Compare Against Peer CEC Listings?

How Jinko Solar Co Ltd Jinko Solar Co Ltd JKMS245PP-60 handles rooftop heat (224.9 W PTC), 8 kW sizing, and cold winter string voltage.

Jinko Solar Co Ltd builds the Jinko Solar Co Ltd JKMS245PP-60 (Multi-c-Si) as a compact residential or specialty off-grid module delivering 149.7 W/m2 (4.94 percentage points below 19.91% CEC median). Compared against Eoplly New Energy Technology EP156P/60-245 AC (245.0 W), this model holds strong 91.8% PTC-to-STC heat retention (#14,745 of 21,677). Lower 37.4 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 13.56 A overcurrent floor served by a 15 A breaker.

## Where Does Jinko Solar Co Ltd JKMS245PP-60 Fall Across Listed CEC Models?

Where Jinko Solar Co Ltd JKMS245PP-60 (245.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Jinko Solar Co Ltd JKMS245PP-60?

Percentile placement of Jinko Solar Co Ltd JKMS245PP-60 across power density (149.7 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Jinko Solar Co Ltd JKMS245PP-60?

Four critical engineering numbers homeowners and solar installers check first when reviewing Jinko Solar Co Ltd JKMS245PP-60 specifications.

Rank #19,942 / 21,677

### 245.0 W STC · Higher Than 7.0%

245.0 W STC (-140.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #19,768

### 14.97% Aperture Efficiency

Power density 149.7 W/m2 (4.94 percentage points below 19.91% CEC median). PTC/STC ratio: 91.8% (rank #14,745).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.56 V at -10 C (581.8 V string) and 42.75 V at -20 C (14 max).

 8 kW Reference Array

### 33 Panels = 8,085 W STC

Occupies 54.0 m2 (581 sq ft) producing 7,422 W PTC; NEC 690.8 OCPD floor is 13.56 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.4 * (1 + (-0.318/100) * (-10 - 25)) = 41.56 V | OCPD = 1.56 * 8.69 = 13.56 A

Inputs from CEC Modules.csv for Jinko Solar Co Ltd JKMS245PP-60: Voc=37.4 V, beta_Voc=-0.318%/C, Isc=8.69 A, STC=245.0 W, Area=1.637 m2.

**Result:** 14 panels max on 600 V (581.8 V); 33 panels for 8 kW (581 sq ft).

## What Are the Published CEC Specifications for Jinko Solar Co Ltd JKMS245PP-60?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Jinko Solar Co Ltd JKMS245PP-60.

Official California Energy Commission (NREL SAM) test parameters for Jinko Solar Co Ltd JKMS245PP-60.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 245.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 224.9 W (91.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 37.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.69 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 30.2 V / 8.12 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.318 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 14.97% (1.637 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Jinko Solar Co Ltd JKMS245PP-60 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Jinko Solar Co Ltd JKMS245PP-60 (245.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 25 | 6.12 kW | 441 sq ft | $1,532 | $2,590 |
| **8 kW Class** | 33 | 8.09 kW | 581 sq ft | $2,025 | $3,424 |
| **10 kW Class** | 41 | 10.04 kW | 722 sq ft | $2,513 | $4,249 |

## How Many Jinko Solar Co Ltd JKMS245PP-60 Modules Fit in a Cold-Weather String?

Maximum series module counts for Jinko Solar Co Ltd JKMS245PP-60 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=37.4V and beta_Voc=-0.318%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 42.75 V | 14 panels | 598.5 V | 23 panels |
| **-10 C (14 F)** | 41.56 V | 14 panels | 581.8 V | 24 panels |
| **0 C (32 F)** | 40.37 V | 14 panels | 565.2 V | 24 panels |
| **25 C (77 F STC)** | 37.4 V | 16 panels | 598.4 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to Jinko Solar Co Ltd JKMS245PP-60?

Alternative CEC solar modules from competing brands near Jinko Solar Co Ltd JKMS245PP-60 (245.0 W), including Eoplly New Energy Technology EP156P/60-245 AC.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Eoplly New Energy Technology EP156P/60-245 AC**](https://epri-peac.com/solar-equipment/modules/eoplly-new-energy-technology/eoplly-new-energy-technology-ep156p-60-245-ac/) Eoplly New Energy Technology | 245.0 W | Tie (0 W) | 37.38 V | 14.99% | 89.8% |
| [**Eoplly New Energy Technology EP156P/60-245W**](https://epri-peac.com/solar-equipment/modules/eoplly-new-energy-technology/eoplly-new-energy-technology-ep156p-60-245w/) Eoplly New Energy Technology | 245.0 W | Tie (0 W) | 37.38 V | 14.99% | 89.8% |
| [**BYD Company Limited BYD245P6K-30**](https://epri-peac.com/solar-equipment/modules/byd-company-limited/byd-company-limited-byd245p6k-30/) BYD Company Limited | 245.0 W | Tie (0 W) | 37.45 V | 15.03% | 91.6% |
| [**Gintung Energy ASEC-245G6M6A**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-245g6m6a/) Gintung Energy | 245.0 W | Tie (0 W) | 37.31 V | 15.21% | 89.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Jinko Solar Co Ltd JKMS245PP-60?

Evaluate Jinko Solar Co Ltd JKMS245PP-60 (245.0 W STC, 37.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Jinko Solar Co Ltd JKMS245PP-60 reaches 42.75 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 33 panels for an 8 kW build require 581 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 33 panels (581 sq ft).
- 2026 tax credit baseline: cash residential installs of Jinko Solar Co Ltd JKMS245PP-60 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Jinko Solar Co Ltd JKMS245PP-60 8 kW Residential Fit

Needs 33 modules (581 sq ft) with a 15 A string OCPD, offsetting ~$2,025/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Eoplly New Energy Technology EP156P/60-245 AC.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 224.9 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Jinko Solar Co Ltd JKMS245PP-60 by Jinko Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Jinko Solar Co Ltd JKMS245PP-60?

Multiplying Jinko Solar Co Ltd JKMS245PP-60's 8.69 A short-circuit current by 1.56 equals 13.56 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can Jinko Solar Co Ltd JKMS245PP-60 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 41.56 V cold Voc at 14 F and handles 8.69 A Isc; string inverters cap Jinko Solar Co Ltd JKMS245PP-60 at 14 panels on 600 V.

### Is Jinko Solar Co Ltd JKMS245PP-60 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Jinko Solar Co Ltd JKMS245PP-60 rely on utility bill offset (~$2,025/yr at 8 kW) rather than 25D.

## Related Pages

Compare Jinko Solar Co Ltd equipment, Eoplly New Energy Technology EP156P/60-245 AC specs, utility payback rates, and NEC string calculators alongside Jinko Solar Co Ltd JKMS245PP-60.

[All Jinko Solar Co Ltd Certified Solar Models](https://epri-peac.com/solar-equipment/brands/jinko-solar-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Jinko Solar Co Ltd

- [All Jinko Solar Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/jinko-solar-co-ltd/)
- [Jinko Solar Co Ltd JKM650N-66HL4M-BDV](https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm650n-66hl4m-bdv/)
- [Jinko Solar Co Ltd JKM635N-66HL4M-BDV](https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm635n-66hl4m-bdv/)
- [Jinko Solar Co Ltd JKM610N-66HL4M-BDV](https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm610n-66hl4m-bdv/)
- [Jinko Solar Co Ltd JKM605N-72HL4-BDV](https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm605n-72hl4-bdv/)
- [Jinko Solar Co Ltd JKM605N-72HL4-BDX](https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm605n-72hl4-bdx/)