title: "Jinko Solar Co Ltd Specs (jinko-solar-co)"
url: https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm605n-72hl4-bdx/
description: "CEC datasheet for Jinko Solar Co Ltd JKM605N-72HL4-BDX: 605.0W STC, 53.5V Voc, 14-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Jinko Solar Co Ltd JKM605N-72HL4-BDX — CEC Solar Module Specifications

Manufacturer: [**Jinko Solar Co Ltd**](https://epri-peac.com/solar-equipment/brands/jinko-solar-co-ltd/) Registry: **CEC Verified Engineering Specification**

Jinko Solar Co Ltd JKM605N-72HL4-BDX is a 605.0 W STC (571.0 W PTC) Mono-c-Si solar module ranking #1,214 of 21,677 CEC listings (top 6.1%; higher than 93.9% of peers). It delivers 23.45% efficiency, 53.5 V Voc at 25 C, and 58.13 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 605.0 W

- **PTC Wattage** : 571.0 W

- **Voc @ 25C** : 53.5 V

- **Efficiency** : 23.45%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Jinko Solar Co Ltd JKM605N-72HL4-BDX Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Jinko Solar Co Ltd JKM605N-72HL4-BDX (Mono-c-Si) residential solar systems.

Homeowners evaluating Jinko Solar Co Ltd JKM605N-72HL4-BDX need 10 panels for 6 kW or 14 panels (389 sq ft) for an 8 kW array—better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. Under NEC 690.7(A), beta_Voc (-0.247%/C) pushes open-circuit voltage to 58.13 V at 14 F and 59.45 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does Jinko Solar Co Ltd JKM605N-72HL4-BDX Fall Across Listed CEC Models?

Comparison of Jinko Solar Co Ltd JKM605N-72HL4-BDX (605.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define Jinko Solar Co Ltd JKM605N-72HL4-BDX?

Relative ranking of Jinko Solar Co Ltd JKM605N-72HL4-BDX across nameplate watts, 94.4% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for Jinko Solar Co Ltd JKM605N-72HL4-BDX?

Summary of Jinko Solar Co Ltd JKM605N-72HL4-BDX output rank, 8 kW array size (14 panels), efficiency rating, and 600 V string limit.

Rank #1,214 / 21,677

### Top 6.1% STC Output

605.0 W STC (+220.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #560

### 23.45% Aperture Efficiency

Power density 234.5 W/m2 (3.54 percentage points above 19.91% CEC median). PTC/STC ratio: 94.4% (rank #2,840).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 58.13 V at -10 C (581.3 V string) and 59.45 V at -20 C (10 max).

 8 kW Reference Array

### 14 Panels = 8,470 W STC

Occupies 36.1 m2 (389 sq ft) producing 7,994 W PTC; NEC 690.8 OCPD floor is 22.23 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 53.5 * (1 + (-0.247/100) * (-10 - 25)) = 58.13 V | OCPD = 1.56 * 14.25 = 22.23 A

Inputs from CEC Modules.csv for Jinko Solar Co Ltd JKM605N-72HL4-BDX: Voc=53.5 V, beta_Voc=-0.247%/C, Isc=14.25 A, STC=605.0 W, Area=2.58 m2.

**Result:** 10 panels max on 600 V (581.3 V); 14 panels for 8 kW (389 sq ft).

## What Are the Published CEC Specifications for Jinko Solar Co Ltd JKM605N-72HL4-BDX?

Complete CEC test sheet for Jinko Solar Co Ltd JKM605N-72HL4-BDX including Isc (14.25 A), Voc (53.5 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Jinko Solar Co Ltd JKM605N-72HL4-BDX.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 605.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 571.0 W (94.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 53.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 14.25 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 44.59 V / 13.57 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.247 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 23.45% (2.58 m2) | Array roof footprint density |
| **Cell Count & Technology** | 24 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Jinko Solar Co Ltd JKM605N-72HL4-BDX Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Jinko Solar Co Ltd JKM605N-72HL4-BDX.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 10 | 6.05 kW | 278 sq ft | $1,514 | $2,561 |
| **8 kW Class** | 14 | 8.47 kW | 389 sq ft | $2,120 | $3,585 |
| **10 kW Class** | 17 | 10.29 kW | 472 sq ft | $2,575 | $4,355 |

## Which Sibling Wattage & Trim Variants Belong to This Jinko Solar Co Ltd Series?

Related Jinko Solar Co Ltd power steps and black/silver trims consolidated into this Jinko Solar Co Ltd JKM605N-72HL4-BDX series guide.

Sibling CEC listings grouped into the Jinko Solar Co Ltd JKM605N-72HL4-BDX wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Jinko Solar Co Ltd JKM600N-72HL4-BDX** | 600.0 W | 566.1 W | 53.3 V | 44.45 V | 23.26% |
| **Jinko Solar Co Ltd JKM605N-72HL4-BDX** | 605.0 W | 571.0 W | 53.5 V | 44.59 V | 23.45% |

## How Many Jinko Solar Co Ltd JKM605N-72HL4-BDX Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Jinko Solar Co Ltd JKM605N-72HL4-BDX (53.5 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=53.5V and beta_Voc=-0.247%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 59.45 V | 10 panels | 594.5 V | 16 panels |
| **-10 C (14 F)** | 58.13 V | 10 panels | 581.3 V | 17 panels |
| **0 C (32 F)** | 56.8 V | 10 panels | 568.0 V | 17 panels |
| **25 C (77 F STC)** | 53.5 V | 11 panels | 588.5 V | 18 panels |

## Which Cross-Brand Solar Modules Compare Closest to Jinko Solar Co Ltd JKM605N-72HL4-BDX?

Four comparable CEC modules such as AEG SOLAR ENERGY SRL ALPS72D30-605/TP (605.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**AEG SOLAR ENERGY SRL ALPS72D30-605/TP**](https://epri-peac.com/solar-equipment/modules/aeg-solar-energy-srl/aeg-solar-energy-srl-alps72d30-605-tp/) AEG SOLAR ENERGY SRL | 605.0 W | Tie (0 W) | 53.5 V | 23.45% | 94.4% |
| [**Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8-605**](https://epri-peac.com/solar-equipment/modules/jiangsu-runergy-new-energy-technology-co-ltd/jiangsu-runergy-new-energy-technology-co-ltd-hy-dh144n8-605/) Jiangsu Runergy New Energy Technology Co Ltd | 605.0 W | Tie (0 W) | 53.5 V | 23.45% | 95.1% |
| [**Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8B-605**](https://epri-peac.com/solar-equipment/modules/jiangsu-runergy-new-energy-technology-co-ltd/jiangsu-runergy-new-energy-technology-co-ltd-hy-dh144n8b-605/) Jiangsu Runergy New Energy Technology Co Ltd | 605.0 W | Tie (0 W) | 53.5 V | 23.45% | 95.1% |
| [**G-Star Pte Ltd GSD7S72T-605BT**](https://epri-peac.com/solar-equipment/modules/g-star-pte-ltd/g-star-pte-ltd-gsd7s72t-605bt/) G-Star Pte Ltd | 605.0 W | Tie (0 W) | 53.57 V | 23.63% | 95.2% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Jinko Solar Co Ltd JKM605N-72HL4-BDX?

Evaluate Jinko Solar Co Ltd JKM605N-72HL4-BDX (605.0 W STC, 53.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Jinko Solar Co Ltd JKM605N-72HL4-BDX reaches 59.45 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 389 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Jinko Solar Co Ltd JKM605N-72HL4-BDX carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Jinko Solar Co Ltd JKM605N-72HL4-BDX 8 kW Residential Fit

Needs 14 modules (389 sq ft) with a 25 A string OCPD, offsetting ~$2,120/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare AEG SOLAR ENERGY SRL ALPS72D30-605/TP.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 571.0 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Jinko Solar Co Ltd JKM605N-72HL4-BDX by Jinko Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Jinko Solar Co Ltd JKM605N-72HL4-BDX PTC wattage (571.0 W) lower than STC (605.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 571.0 W PTC (94.4% retention) across Jinko Solar Co Ltd JKM605N-72HL4-BDX's 2.58 m2 aperture.

### Who should skip Jinko Solar Co Ltd JKM605N-72HL4-BDX on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 14 Jinko Solar Co Ltd JKM605N-72HL4-BDX panels (389 sq ft) leave unusable roof gaps vs. AEG SOLAR ENERGY SRL ALPS72D30-605/TP.

### What is the 1,000 V commercial string limit for Jinko Solar Co Ltd JKM605N-72HL4-BDX?

On 1,000 V commercial inverters at -10 C (58.13 V cold Voc), Jinko Solar Co Ltd JKM605N-72HL4-BDX fits up to 17 panels per series string.

## Related Pages

Compare Jinko Solar Co Ltd equipment, AEG SOLAR ENERGY SRL ALPS72D30-605/TP specs, utility payback rates, and NEC string calculators alongside Jinko Solar Co Ltd JKM605N-72HL4-BDX.

[All Jinko Solar Co Ltd Certified Solar Models](https://epri-peac.com/solar-equipment/brands/jinko-solar-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Jinko Solar Co Ltd

- [All Jinko Solar Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/jinko-solar-co-ltd/)
- [Jinko Solar Co Ltd JKM650N-66HL4M-BDV](https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm650n-66hl4m-bdv/)
- [Jinko Solar Co Ltd JKM635N-66HL4M-BDV](https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm635n-66hl4m-bdv/)
- [Jinko Solar Co Ltd JKM610N-66HL4M-BDV](https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm610n-66hl4m-bdv/)
- [Jinko Solar Co Ltd JKM605N-72HL4-BDV](https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm605n-72hl4-bdv/)
- [Jinko Solar Co Ltd JKM595N-66HL4M-BDV](https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm595n-66hl4m-bdv/)